Electrochemistry Meters
Filtered Search Results
Mettler Toledo™ pH/Ion Meter SevenDirect SD50
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
The SevenDirect SD50 is an accurate and flexible benchtop meter for the determination of pH, ORP and ion concentrations. The instrument is the replacement of the SevenCompact and is delivered with an EasyPlace sensor arm.
| Temperature Accuracy | ±0.1°C between 0°C and 100°C |
|---|---|
| Memory | 2000 Standard Measurements |
| Resolution (pH) | 0.1, 0.01, 0.001 |
| Measurement Modes | pH |
| Range (pH) | -2.000 to 20.000 |
| Accuracy (Ion) | 0.5 % |
| Channels | 1 |
| Accuracy (pH) | 0.002 |
| Dimensions (L x W x H) | 195 x 205 x 65 mm |
| Data Management Details | PC, Printer, USB Stick |
| Display Type | Color TFT |
| IP Rating | IP54 |
| Resolution (Ion) | 3 or 4 digits (auto-range) |
| Temperature Range (English) | -22°F to +266°F |
| Range (Ion) | -2,000 to 20,000 pX, 0 to 999,999 mg/L (ppm) |
| Temperature Range (Metric) | -30°C to +130°C |
| Range (mV) | -2000 to 2000 mV |
| Temperature Resolution | 0.1°C |
Thermo Scientific™ Elite PCTS pH / Conductivity / TDS / Salinity Pocket Testers and Replacement Sensors
Flexible on-the-go pH, conductivity, TDS, salinity and temperature testing using durable Elite PCTS pocket testers for a variety of applications including agriculture, aquaculture, hydroponics and more!
| Salinity Measurement Modes | Per practical salinity curve |
|---|---|
| Temperature Accuracy | ±0.6°C, ±1.0°F for 0.0 to 50.0°C; ±1.1°C, ±1.9°F for 50.1 to 60.0°C |
| Resolution (Conductivity) | 0.1 μS/cm for 0.0 to 200.0 μS/cm; 1 μS/cm for200 to 2000 μS/cm; 0.01 mS/cm for 2.00 to 20.00 mS/cm |
| Range (Conductivity) | 0.00 to 20.00 mS/cm |
| Resolution (pH) | 0.01 |
| Range (TDS) | 0.00 to 10.00 ppt |
| Measurement Modes | pH,Conductivity,TDS,Salinity,Temperature |
| Resolution (TDS) | 0.1 ppm for 0.0 to 100.0 ppm; 1 ppm for 100 to 1000 ppm; 0.01 ppt for 0.10 to 10.00 ppt |
| Range (pH) | -1.00 to 15.00 |
| TDS Factor Range | 0.40 to 1.00 (selectable) |
| Accuracy (pH) | ±0.02 |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Range (Salinity) | 0.00 to 10.00 ppt |
| Temperature Compensation | Yes |
| Accuracy (TDS) | ± 1% full scale |
| Accuracy (Salinity) | ± 1% full scale |
| Resolution (Salinity) | 0.10 ppt |
| Accuracy (Conductivity) | ± 1% full scale |
| Temperature Range (English) | 32.0°F to 140.0°F |
| Calibration Points (pH) | 1 to 3 |
| Calibration Modes | pH, conductivity, TDS, salinity, temperature |
| Temperature Probe Calibration | 1 point |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Resolution | 0.1°C, 0.1°F |
| Calibration Points (Conductivity) | 1 to 3 |
Thermo Scientific™ Orion Star™ A322 Conductivity Portable Meter
Accurately monitor conductivity, TDS, salinity, resistivity and temperature with this conductivity portable meter designed for challenging field tests.
| Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) |
|---|---|
| Range (Resistivity) | 2 ohm to 100.0 megohm |
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
| Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
| Measurement Modes | Conductivity,TDS,Salinity,Resistivity with Temperature |
| Power Supply | 4 AA batteries (included) or universal AC adapter (sold separately) |
| Battery Life | 800 hr. |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Display Type | Graphic LCD with Backlight |
| Data Points | 5000 with Date and Time Stamp |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
| Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
| Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
| Battery Type | 4 x AA (included) |
| Relative Humidity Range | 5 to 85%, non-condensing |
| Dimensions (L x W x H) | 24 x 10 x 6.5 cm (9.5 x 3.9 x 2.6 in.) |
| Accuracy (TDS) | 0.5% of reading ±1 digit |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB, RS232 |
| Backlight Option | Yes (Selectable) |
| Compatible Probes | 2-cell or 4-cell conductivity sensors with built-in temperature |
| Methods | 10 per channel with password protection |
| Cell Constant | 0.001 to 199.9cm-1 |
| Temperature (Metric) Reference | 5, 10, 15, 20, 25°C |
| Channels | 1 |
| TDS Factor Range | Linear (0.02 to 9.99) |
| Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
| Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off wit |
| Accuracy (Salinity) | 0.5% of reading ±1 digit |
| Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
| Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
| Inputs | 8 pin MiniDIN (conductivity sensor with built-in temperature) |
| Accuracy (Temperature) | ±0.1°C |
| Weight (Metric) | 0.5 kg |
| Calibration Points (Conductivity) | 5 |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Resolution (Resistivity) | 1 ohm or 0.1 megohm, auto ranging |
| Accuracy (Resistivity) | 0.5% of reading ±1 digit |
| Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
| Calibration | Conductivity with calibration editing option and temperature |
| Alarm Output | High/low limit alarm, calibration due alarm |
| IP Rating | IP67 |
| Model | Orion Star A322 Conductivity/TDS/Salinity/Resistivity/Temperature Portable Meter |
| Weight (English) | 1.2 lb. |
| Resolution (Temperature) | 0.1°C (0.1°F) |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5°C to +105°C |
Fisherbrand™ Traceable™ Expanded Range Conductivity Meter
Ideal for checking the purity of water from stills, deionizers, and reverse osmosis, testing laboratory glassware rinsing, measuring total dissolved solids, and making solutions.
Fisherbrand™ Traceable™ Conductivity/TDS Meter Pen
Easy-to-use, waterproof conductivity/TDS meter designed for routine analysis and quality control. Simply turn on, insert, and simultaneously read result and temperature.
Fisherbrand™ Traceable™ pH/ORP/Temperature Meter
Measure critical water quality parameters — without the need to carry multiple units.
Thermo Scientific™ Orion™ Pro Star PC215 pH/ion and Conductivity Bench Meter with Stand
Designed to provide accurate and reliable pH, ORP, ion concentration, conductivity, TDS, salinity, resistivity and temperature analysis, the Thermo Scientific™ Orion™ Pro Star PC215 bench meter is well suited for laboratories that desire a modern meter with advance performance.
| Salinity Measurement Modes | Natural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl |
|---|---|
| Range (Resistivity) | 1.0 Ω to 100.0 MΩ |
| Memory | Non-volatile |
| Advanced ISE Functions | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
| Resolution (pH) | 0.1, 0.01 or 0.001 pH |
| Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
| Resolution (ISE) | 0.0001 minimum, 1 to 5 digits |
| Display Type | 7-in. High-resolution Color Graphic LCD |
| Resolution (mV) | 0.1 mV |
| Resolution (Ion) | 0.0001 minimum, 1 to 5 digits |
| Data Points | 10,000 with Date and Time Stamp |
| Temperature Probe Calibration | 1 or 2 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Accuracy (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Warranty | 2 year meter warranty |
| Temperature Accuracy | ±0.3°C, ±0.5°F |
| Calibration Points (ISE) | Up to 5 |
| Resolution (Conductivity) | 0.001 μS/cm minimum, auto-ranging, up to 4 digits |
| Range (Conductivity) | 0.010 μS/cm to 3000 mS/cm |
| Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Dimensions (L x W x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
| Accuracy (TDS) | ±0.5% reading |
| Temperature Selection | Automatic with ATC temperature sensor, ambient or manual |
| Keypad | Capacitive touchscreen user interface |
| Outputs | USB flash drive, computer or printer (STARA-106) |
| Temperature Range (English) | -22.0°F to +266.0°F |
| Range (Relative mV) | -2000 to 2000 mV |
| Calibration Points (pH) | 1 to 5 points |
| Backlight Option | Yes |
| Range (mV) | -2000 to 2000 mV |
| Range (ORP) | -2000 to 2000 mV |
| Methods | 10 per channel (20 total) |
| Cell Constant | 0.100 cm-1, 0.475 cm-1, 0.550 cm-1, 1.000 cm-1, 10.00 cm-1 or user-defined from 0.001 to 199.9 cm-1 |
| Temperature (Metric) Reference | 5, 10, 15, 20, 25 or 30°C |
| Range (pH) | -2 to 20 |
| TDS Factor Range | Linear (0.01 to 10.00), ISO/EN 27888, 442, NaCl |
| Channels | 2 |
| Accuracy (pH) | ±0.002 pH |
| Range (ISE) | 0.0001 to 19999 |
| Range (Salinity) | 0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl |
| Temperature Compensation | Linear (0.00 to 10.00 %/°C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP/USP or off |
| Accuracy (Salinity) | ±0.5% reading |
| Resolution (Salinity) | 0.001 ppt minimum; 0.01 PSU minimum; or 0.01% NaCl minimum, auto-ranging |
| Accuracy (Conductivity) | ±0.5% reading |
| Inputs | Channel 1: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference; Channel 2: 8-pin MiniDIN for conductivity with ATC |
| Weight (Metric) | 1.00 kg |
| Resolution (ORP) | 0.1 mV |
| Calibration Points (Conductivity) | 1 to 5 points |
| Resolution (Resistivity) | 0.1 Ω minimum, auto-ranging |
| Isopotential Point | 7.000 pH; 1.000 ion concentration |
| Accuracy (Resistivity) | ±0.5% reading |
| AC Adapter | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Range (TDS) | 0.010 ppm to 500.0 ppt (TDS factor of 1.00); or 0.010 mg/L to 500.0 g/L (TDS factor of 1.00) |
| Resolution (TDS) | 0.001 ppm or mg/L minimum, auto-ranging, up to 4 digits |
| Calibration | pH, ORP, Ion Concentration, Conductivity, TDS, Salinity, Temperature |
| Accuracy (ORP) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Calibration Points | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 5 (conductivity), 1 to 5 (TDS), 1 (salinity), 1 to 2 (temperature) |
| Alarm Output | Calibration reminder alarm, high and low limit alarm per parameter |
| IP Rating | IP54 |
| Weight (English) | 2.20 lbs. |
| Range (Ion) | 0.0001 to 19999 |
| Temperature Range (Metric) | -30.0°C to +130.0°C |
| Temperature Resolution | 0.1°C, 0.1°F |
Fisherbrand™ accumet™ XL500 Benchtop Dual pH/ISE and Conductivity Meters
Provide advanced measurements with simple operation and offer a large, vivid color touch-screen display that allows for dynamic functionality. Fisherbrand accumet XL500 dual pH/ISE/conductivity benchtop meters offer advanced features with simple operation to help ensure your measurements are reliable and your laboratory processes are efficient.
| Length (Metric) | 24.6 cm |
|---|---|
| Range (Resistivity) | 3 W to 100 MW over 4 ranges: 0 to 20 kW, 20 to 200 kW, 200 kW to 2 MW, 2 to 100 MW |
| Detection Range | Multiple |
| Length (English) | 9.68 in. |
| Resolution (pH) | 0.1/0.01/0.001 |
| Cell Constant | 0.01 to 10 |
| Range (pH) | -2 to 20 |
| Width (Metric) | 17.3 cm |
| Resolution (ISE) | 2/3/4 Digits |
| Accuracy (pH) | ±0.002 |
| Range (ISE) | ±2000 mV |
| Range (Salinity) | 0 to 80 ppt |
| Accuracy | Multiple |
| Data Management Details | 3 to 86400 sec. |
| Display Type | LCD |
| Accuracy (Salinity) | ± 1% full scale |
| Resolution (Salinity) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
| Voltage | 100/240 V |
| Accuracy (Conductivity) | ±1% FS |
| Resolution (mV) | 0.1mV |
| Data Points | 2000 |
| Certifications/Compliance | NIST, ISO, FDA, USDA, EPA |
| Inputs | 2 BNC, 2 ATC |
| Weight (Metric) | 1.13 kg |
| Height (English) | 3.89 in. |
| Calibration Points (Conductivity) | Automatic (4 points), maximum 1/range, manual (5 points), maximum 1/range |
| Height (Metric) | 9.9 cm |
| Accuracy (mV) | ±0.2 mV |
| Accuracy (ISE) | 0.5% full scale (monovalent ion), 1% full scale (divalent ion) |
| Warranty | 3 Years |
| Temperature Accuracy | ±0.3°C |
| Calibration Points (ISE) | 2 to 6 |
| Resolution (Resistivity) | 0.01/0.1W, 0.001/0.1kW, 0.01MW |
| Resolution (Conductivity) | 0.001/0.01/0.1mS |
| Range (Conductivity) | 0 to 500 mS |
| Accuracy (Resistivity) | ± 1% full scale |
| Range (TDS) | 0.050 ppm to 500 ppt (at TDS factor 1.00) |
| Resolution (TDS) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
| Dimensions (L x W x H) | 24.6 x 17.3 x 9.9cm (9.7 x 6.8 x 3.9 in.) |
| Accuracy (TDS) | ± 1% full scale |
| Outputs | RS232, USB-A, Mini-B USB, RJ45, stirrer port (2) |
| Frequency | 50/60Hz |
| Calibration Points (pH) | Up to 6 preset or 5 custom |
| Weight (English) | 2.5 lb. |
| Range (mV) | ±2000 mV |
| Temperature Resolution | 0.1°C |
| Resolution | Multiple |
Fisherbrand™ accumet™ XL200 Benchtop pH/Conductivity Meters
Provide advanced measurements with simple operation and offer a large, vivid color touch-screen display that allows for dynamic functionality. Fisherbrand accumet XL200 pH/Conductivity benchtop meters offer advanced features with simple operation to help ensure your measurements are reliable and your laboratory processes are efficient.
| Length (Metric) | 24.6 cm |
|---|---|
| Range (Resistivity) | 3 W to 100 MW over 4 ranges: 0 to 20 kW, 20 to 200 kW, 200 kW to 2 MW, 2 to 100 MW |
| Detection Range | Multiple |
| Length (English) | 9.68 in. |
| Resolution (pH) | 0.1/0.01/0.001 |
| Cell Constant | 0.01 to 10 |
| Range (pH) | -2 to 20 |
| Width (Metric) | 17.3 cm |
| Accuracy (pH) | ±0.002 |
| Range (Salinity) | 0 to 80 ppt |
| Accuracy | Multiple |
| Data Management Details | 3 to 86400 sec. |
| Display Type | LCD |
| Accuracy (Salinity) | ± 1% full scale |
| Resolution (Salinity) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
| Voltage | 100/240 V |
| Accuracy (Conductivity) | ±1% FS |
| Resolution (mV) | 0.1mV |
| Data Points | 2000 |
| Certifications/Compliance | NIST, ISO, FDA, USDA, EPA |
| Inputs | BNC, ATC |
| Weight (Metric) | 1.13 kg |
| Height (English) | 3.89 in. |
| Calibration Points (Conductivity) | Automatic (4 points), maximum 1/range, manual (5 points), maximum 1/range |
| Height (Metric) | 9.9 cm |
| Accuracy (mV) | ±0.2 mV |
| Warranty | 3 Years |
| Temperature Accuracy | ±0.2°C |
| Resolution (Resistivity) | 0.01/0.1W, 0.001/0.1kW, 0.01MW |
| Resolution (Conductivity) | 0.001/0.01/0.1mS |
| Range (Conductivity) | 0 to 500 mS |
| Accuracy (Resistivity) | ± 1% full scale |
| Range (TDS) | 0.050 ppm to 500 ppt (at TDS factor 1.00) |
| Resolution (TDS) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
| Dimensions (L x W x H) | 24.6 x 17.3 x 9.9cm (9.7 x 6.8 x 3.9 in.) |
| Accuracy (TDS) | ± 1% full scale |
| Outputs | RS232, USB-A, Mini-B USB, RJ45, stirrer port (2) |
| Frequency | 50/60Hz |
| Calibration Points (pH) | Up to 6 preset or 5 custom |
| Weight (English) | 2.5 lb. |
| Range (mV) | ±2000 mV |
| Temperature Resolution | 0.1°C |
| Resolution | Multiple |
Fisherbrand™ Traceable™ Dual-Display Conductivity Meter
Measures conductivity and temperature; includes NIST™ traceability certificate.
Fisherbrand™ Traceable™ Portable Dissolved Oxygen Meter
Traceable™ Portable Dissolved Oxygen Meter is traceable to NIST™ standards.
Fisherbrand™ accumet™ XL600 Benchtop Dual pH/ISE, Conductivity and Dissolved Oxygen Meters
Provide advanced measurements with simple operation and offer a large, vivid color touch-screen display. Fisherbrand accumet XL600 pH/ISE/conductivity/DO benchtop meters offer advanced features with simple operation to help ensure your measurements are reliable and your laboratory processes are efficient.
| Range (Resistivity) | 3 W to 100 MW over 4 ranges: 0 to 20 kW, 20 to 200 kW, 200 kW to 2 MW, 2 to 100 MW |
|---|---|
| Resolution (pH) | 0.1/0.01/0.001 |
| Width (Metric) | 17.3 cm |
| Resolution (ISE) | 2/3/4 Digits |
| Data Management Details | 3 to 86400 sec. |
| Display Type | LCD |
| Resolution (mV) | 0.1mV |
| Data Points | 2000 |
| Certifications/Compliance | NIST, ISO, FDA, USDA, EPA |
| Height (English) | 3.89 in. |
| Accuracy (mV) | ±0.2 mV |
| Accuracy (ISE) | 0.5% full scale (monovalent ion), 1% full scale (divalent ion) |
| Warranty | 3 Years |
| Temperature Accuracy | ±0.2°C (±0.3°F) |
| Calibration Points (ISE) | 2 to 6 |
| Resolution (Conductivity) | 0.001/0.01/0.1mS |
| Range (Conductivity) | 0 to 500 mS |
| Dimensions (L x W x H) | 24.6 x 17.3 x 9.9cm (9.7 x 6.8 x 3.9 in.) |
| Accuracy (TDS) | ± 1% full scale |
| Outputs | RS232, USB-A, Mini-B USB, RJ45, stirrer port (2) |
| Calibration Points (pH) | Up to 6 preset or 5 custom |
| Range (mV) | ±2000 mV |
| Resolution | Multiple |
| Length (Metric) | 24.6 cm |
| Detection Range | Multiple |
| Length (English) | 9.68 in. |
| Cell Constant | 0.01 to 10 |
| Range (pH) | -2 to 20 |
| Accuracy (pH) | ±0.002 |
| Range (ISE) | ±2000 mV |
| Range (Salinity) | 0 to 80 ppt |
| Accuracy | Multiple |
| Accuracy (Salinity) | ± 1% full scale |
| Resolution (Salinity) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
| Voltage | 100/240 V |
| Accuracy (Conductivity) | ±1% FS |
| Resolution (DO) | 0.01mg/L (0.1mbar), 0.1% saturation |
| Inputs | 2 BNC, 2 ATC |
| Weight (Metric) | 1.13 kg |
| Calibration Points (Conductivity) | Automatic (4 points), maximum 1/range, manual (5 points), maximum 1/range |
| Height (Metric) | 9.9 cm |
| Accuracy (DO) | 0.1 +1 LSD |
| Resolution (Resistivity) | 0.01/0.1W, 0.001/0.1kW, 0.01MW |
| Accuracy (Resistivity) | ± 1% full scale |
| Range (TDS) | 0.050 ppm to 500 ppt (at TDS factor 1.00) |
| Resolution (TDS) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
| Frequency | 50/60Hz |
| Weight (English) | 2.5 lb. |
| Range (DO) | 0 to 20mg/L (0 to 1272mbar), 0 to 200% saturation with 13-620-SSP electrode |
| Temperature Resolution | 0.1°C |
Fisherbrand™ accumet™ AP125 Portable pH/Ion/mV/Temperature Meter Kit
Accurate measurements any time, anywhere
Fisherbrand™ accumet™ AP125 Portable pH/Ion/mV/Temperature Meter
Accurate measurements any time, anywhere
| Accuracy (mV) | 0 to ±2000mV |
|---|---|
| Warranty | 3 Years |
| Resolution (pH) | Adjustable |
| Measurement Modes | pH,Ion,mV,Temperature |
| Range (pH) | 2 to 20 |
| Range | -2 to +20pH |
| For Use With (Application) | pH, Ion concentration, mV, Temperature |
| Includes | Meter, 9V battery, manual |
| Calibration Points | 10 |
| Accuracy | Multiple |
| Display Type | LCD |
| Product Type | Meter Only |
| IP Rating | IP67 |
| Temperature Range (English) | 23°F to 212°F |
| Data Points | 200 |
| Temperature Range (Metric) | -5°C to +100°C |
| Range (mV) | 0 to ±2000 mV |
| Resolution | Multiple |
Fisherbrand™ Traceable™ Conductivity Meter Pen
Easy-to-use, waterproof conductivity meter designed for routine analysis and quality control. Simply turn on, insert, and simultaneously read result and temperature.