Electrochemistry Meters
Filtered Search Results
| Product Type | Fruit Juices Meter Test Kit |
|---|
METTLER TOLEDO™ SevenCompact™ S213 pH/Conductivity Benchtop Meter
The S213 meter measures pH, conductivity, and ion concentration. A simple and durable interface with only 2 buttons makes this meter very easy to operate, and results can be captured by a printer with a time and date stamp. Available as meter only or ready-to-use kits for specific applications.
| Range (Resistivity) | 0.00 to 100.0 Mohm/cm |
|---|---|
| Memory | 1.000 measurements |
| Languages | Chinese, Chinese (TW), Croatian, Czech, Danish, Dutch, English (GB), English (US), French, German, Hungarian, Indonesian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese (BR), Russian, Slovak, Slovenian, Spanish, Swedish, Thai, Turkish, Vietnamese |
| Measurement Modes | Routine mode/expert mode |
| Range (pH) | -2 to 20 |
| Channels | 2 |
| Accuracy (pH) | ±0.002 |
| Power Supply | 9 to 12V DC, 2.5w |
| Range (Salinity) | 0.00 to 80.00 psu/ppt |
| Temperature Compensation | Linear, non-linear, off, pure-water |
| Data Management Details | USB-stick, EasyDirect pH PC software |
| Display Type | Color TFT |
| Accuracy (Salinity) | ±0.5% |
| Resolution (Salinity) | 0.00 to 1.0 |
| Accuracy (Conductivity) | ±0.5% |
| Resolution (mV) | 0.1, 1 |
| Weight (Metric) | 890 g |
| Calibration Points (Conductivity) | 1 |
| Accuracy (mV) | ±0.1mV in -1000 to 1000 mV; ±0.2mV outside |
| Temperature Accuracy | ±0.1°C |
| Resolution (Resistivity) | 0.00 to 1.0 |
| Resolution (Conductivity) | 0.001 to 1 |
| Isopotential Point | pH 7.00 |
| Range (Conductivity) | 0.001 μS/cm to 1000 mS/cm |
| Accuracy (Resistivity) | ±0.5% |
| Range (TDS) | 0.00 mg/L to 1000 g/L |
| Resolution (TDS) | 0.01 to 1 |
| Relative Humidity Range | 5 to 80% (non-condensing) |
| Calibration Points | Conductivity 1; pH Max. 5 |
| Dimensions (L x W x H) | 20.4 x 17.4 x 7.4cm |
| Accuracy (TDS) | ±0.5% |
| Temperature Selection | Automatic or manual |
| IP Rating | IP54 |
| Keypad | Membrane keypad: Polyethylene terephthalate (PET) |
| Model | SevenCompact Duo S213 |
| Range (Relative mV) | -2000.0 to 2000.0 |
| Calibration Points (pH) | Up to 5 |
| Temperature Range (Metric) | -5°C to +130°C (ATC), -30°C to +130°C (MTC) |
| Range (mV) | -2000.0 to 2000.0 |
| Temperature Resolution | 0.1°C |
Thermo Scientific™ Orion Star™ A215 pH/Conductivity Benchtop Multiparameter Meter
Reliably measure pH, conductivity and temperature with our pH/conductivity benchtop meter for advanced lab analysis and interfacing.
| Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) |
|---|---|
| Range (Resistivity) | 2 ohm to 100.0 meg-ohm |
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
| Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
| Power Supply | Universal AC adapter (included) or 4 AA batteries (sold separately) |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Battery Life | 800 hr. |
| Display Type | LCD Graphic, Backlit |
| Resolution (mV) | 0.1mV |
| Data Points | 2000 with Date and Time Stamp |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Warranty | 3 Year Meter |
| Temperature Accuracy | ±0.1°C |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
| Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
| Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
| Battery Type | 4 AA (sold separately) |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Dimensions (L x W x H) | 24cm x 18cm x 11cm (9.5 in. x 7.1 in. x 4.3 in.) |
| Accuracy (TDS) | 0.5% of reading ±1 digit |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB, RS232 |
| Temperature Range (English) | 22.0°F to 221.0° F |
| Range (Relative mV) | ±2000.0 mV |
| Calibration Points (pH) | 1 to 5 |
| Backlight Option | Yes (Selectable) |
| Range (mV) | ±2000.0 mV |
| Range (ORP) | ±2000.0 mV |
| Methods | 10 per channel with password protection |
| Cell Constant | 0.001 to 199.9cm-1 |
| Temperature (Metric) Reference | 5, 10, 15, 20, 25°C |
| Range (pH) | -2 to 20 |
| TDS Factor Range | Linear (0.02 to 9.99) |
| Channels | 2 |
| Accuracy (pH) | ±0.002 |
| Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
| Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off |
| Accuracy (Salinity) | 0.5% of reading ±1 digit |
| Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
| Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
| Inputs | BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe), stirrer input (stirrer probe) |
| Weight (Metric) | 0.9 kg |
| Calibration Points (Conductivity) | Up to 5 |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Resolution (Resistivity) | 1 ohm or 0.1 meg-ohm, auto ranging |
| Isopotential Point | 7.000pH |
| Accuracy (Resistivity) | 0.5% of reading ±1 digit |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. 1010003) |
| Range (TDS) | 0.001 ppm to 200.0 ppt |
| Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
| Calibration | pH with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing op |
| Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
| Alarm Output | High/low limit alarm, calibration due alarm |
| IP Rating | IP54 |
| Model | Orion Star A215 pH/mV/RmV/ORP/Conductivity/TDS/Salinity/Resistivity/Temperature Benchtop Meter |
| Weight (English) | 2 lb. |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5.0°C to +105.0°C |
| Temperature Resolution | 0.1°C, 0.1°F |
Thermo Scientific™ Orion™ Star A329 pH, ISE, Conductivity, Dissolved Oxygen, RDO and Temperature Portable Waterproof Multiparameter Meter Kit - PROMO
Get laboratory accuracy everywhere you need it with advanced meter features in this portable, IP67 waterproof meter.
Thermo Scientific™ Orion Star™ A214 pH/ISE Benchtop Meter
Reliably measure pH, ion concentration, mV, ORP and temperature with our pH/ISE benchtop meter for advanced lab analysis and interfacing.
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
|---|---|
| Advanced ISE Functions | Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit |
| Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
| Measurement Modes | pH,mV,Relative mV,ORP,Ion Concentration (ISE) with Temperature |
| Resolution (ISE) | 0.0001 minimum, 1 to 3 significant digits (user selectable) |
| Power Supply | Universal AC adapter (included) or 4 AA batteries (sold separately) |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Battery Life | 800 hr. |
| Display Type | LCD Graphic, Backlit |
| Resolution (mV) | 0.1mV |
| Data Points | 2000 with Date and Time Stamp |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Warranty | 3 Year Meter |
| Temperature Accuracy | ±0.1°C |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Calibration Points (ISE) | 1 to 5 |
| Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
| Battery Type | 4 AA (sold separately) |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Dimensions (L x W x H) | 24cm x 18cm x 11cm (9.5 in. x 7.1 in. x 4.3 in.) |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB, RS232 |
| Temperature Range (English) | 22.0°F to 221.0° F |
| Range (Relative mV) | ±2000.0 mV |
| Calibration Points (pH) | 1 to 5 |
| Backlight Option | Yes (Selectable) |
| Range (mV) | ±2000.0 mV |
| Range (ORP) | ±2000.0 mV |
| Methods | 10 per channel with password protection |
| Range (pH) | -2 to 20 |
| Channels | 1 |
| Accuracy (pH) | ±0.002 |
| Range (ISE) | 0.0001 to 19900 with selectable units of ppm, Molar, mg/L, %, ppb or none |
| Inputs | BNC (pH, ORP or ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe) |
| Weight (Metric) | 0.9 kg |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Isopotential Point | 7.000pH |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. 1010003) |
| Calibration | pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ |
| Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
| Alarm Output | High/low limit alarm, calibration due alarm |
| IP Rating | IP54 |
| Model | Orion Star A214 pH/ISE/mV/RmV/ORP/Temperature Benchtop Meter |
| Weight (English) | 2 lb. |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5.0°C to +105.0°C |
| Temperature Resolution | 0.1°C, 0.1°F |
Mettler Toledo™ V20S Compact Volumetric KF Titrator
Ideal for fast and precise water content determination with easy operation. Mettler Toledo V20S Compact Volumetric KF Titrators can analyze samples with water content between 100 ppm and 100% in single measurements or sample series with statistics.
Thermo Scientific™ Orion™ 3-Star Plus Dissolved Oxygen Portable Meter
Waterproof, battery-operated meter stands up to the most demanding field applications
Thermo Scientific™ Orion Star™ A213 Dissolved Oxygen Benchtop Meter
Reliably measure dissolved oxygen (RDO optical/polarographic) and temperature with this benchtop meter for advanced lab analysis.
| Temperature (Metric) Range | 0.0°C to 50.0°C |
|---|---|
| Resolution (Polarographic DO) | 0.01, 0.1mg/L |
| Pressure Range | 400 to 850 mmHg |
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
| Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
| Measurement Modes | Dissolved Oxygen (% Saturation),Dissolved Oxygen (mg/L with Temperature and Barometric Pressure) |
| Power Supply | Universal AC adapter (included) or 4 AA batteries (sold separately) |
| Barometric Pressure Correction | 400 to 850mmHg, automatic using built-in barometer or manual entry |
| Battery Life | 800 hours |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Display Type | Graphic LCD with Backlight |
| Data Points | 2000 with Date and Time Stamp |
| Calibration Modes | Water-saturated air, air-saturated water, manual (Winkler titration), zero point |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Salinity Factor | 0.0 to 45.0 ppt, automatic correction using manual entry of sample salinity |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Warranty | 3 Year Meter Warranty |
| Sensor Types | RDO optical dissolved oxygen sensor or polarographic dissolved oxygen sensor |
| Percent Saturation Range Polarographic DO | 0.0 to 600.0 % saturation |
| Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
| Battery Type | Four AA (sold separately) |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Range (RDO) | 0.00 to 50.00 mg/L |
| Dimensions (L x W x H) | 24 cm x 18 cm x 11 cm (9.5 in. x 7.1 in. x 4.3 in.) |
| Percent Saturation Range (RDO) | 0.0 to 500.0 % saturation |
| Temperature Selection | Automatic with ATC temperature probe |
| Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB, RS232 |
| Backlight Option | Yes (Selectable) |
| Percent Saturation Relative Accuracy (RDO) | ±2 % saturation ≤ 200 % saturation, ±10 % saturation > 200 % saturation |
| Range (Polarographic DO) | 0.00 to 90.00 mg/L |
| Accuracy (Barometer) | ±6mmHg |
| Methods | 10 per channel with password protection |
| Pressure Resolution | 1 mmHg |
| Channels | 1 |
| Resolution (RDO) | 0.01, 0.1mg/L |
| Percent Saturation Resolution (RDO) | 0.1, 1 % saturation |
| Percent Saturation Relative Accuracy (Polarographic DO) | ±2 % saturation or ±2% of reading whichever is greater |
| Inputs | 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe) |
| Accuracy (Temperature) | ±0.1°C |
| Weight (Metric) | 0.9 kg |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Accuracy (Polarographic DO) | ±0.2mg/L or ±2% of reading, whichever is greater |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. 1010003) |
| Alarm Output | High/low limit alarm, calibration due alarm |
| IP Rating | IP-54 |
| Percent Saturation Resolution (Polarographic DO) | 0.1, 1 % saturation |
| Model | Orion Star A213 RDO Optical/Dissolved Oxygen/Temperature Benchtop Meter |
| Weight (English) | 2 lb. |
| Resolution (Temperature) | 0.1°C (0.1°F) |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Percent Saturation Range (Polarographic DO) | 0.0 to 600.0 % saturation |
| Accuracy (RDO) | ±0.1mg/L up to 8mg/L, ±0.2mg/L from 8 to 20mg/L, ±10% of reading up to 50mg/L |
Thermo Scientific™ EC112 Conductivity/TDS/Salinity Bench Meter Standard Kit PROMO
Orion Lab Star EC112 conductivity bench meters measure conductivity, salinity or TDS with temperature, feature a large backlit display for easy viewability, and offer small footprint to save bench space. Ideal for simplified, budget-friendly lab testing and data recording.