Choose the brand aligned with your industry so we can best serve your needs.
For researchers, scientists, and technical professionals: Your one-stop shop for the complete range of laboratory, production, and safety products and services.
Small and Specialty Supplier Partner Small and/or specialty supplier based on Federal laws and SBA requirements. Learn More
The Instech VABM2T/25 is a two‑channel mouse VAB™ tether designed for simultaneous infusion and sampling when paired with a VABM2B‑series button. It includes two 10in (25cm) PU tubing lines—one clear and one blue‑stripe—each sized .017x.037in (0.43x0.94mm), a 7in (18cm) PS80 spring, and a 2‑channel 25ga connector. Red‑dot alignment ensures correct pairing with the red and white ports. Each channel has a 40µL dead volume, supporting low‑loss micro‑sampling workflows.
Features
2‑channel mouse VAB™ tether
10in (25cm) PU tubing, clear + blue‑stripe
.017x.037in (0.43x0.94mm) tubing size
7in (18cm) PS80 spring
25ga dual‑channel connector
40µL dead volume per channel
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
Many fractures in feline and small canine patients are too small for the 2.0mm DCP and the 2.7mm CDP is too large.The difference between these plates is enormous compared to the difference between 2.7 and 3.5 CDPs. The AMI (resistance to bending) of the 2.7 CDP is 20 times stiffer than the 2.0 DCP. The AMI of the 2.4 DCP is 10 times that of the 2.0 DCP.The solution is a 2.4 series of plates and screws. The plates in both size and strength are midway between 2.0 and 2.7 DCPs. The range and specifications are shown below. The standard 1.5mm hex screwdriver (used for 1.5 and 2.0 screws) is required. The pilot drill is 1.8mm and dedicated instrumentation such as load/neutral guides are also available.
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
2.4 DCPs and Screws. On a regular basis we find that for many fractures in feline and small canine patients the regular 2.0 DCP is too small and the 2.7 CDP is too large. The difference between these plates is enormous compared to the difference between 2.7 and 3.5 CDPs. The AMI (resistance to bending) of the 2.7 CDP is 20 times stiffer than the 2.0 DCP. The AMI of the 2.4 DCP is 10 times that of the 2.0 DCP. The solution is a 2.4 series of plates and screws. The plates in both size and strength are midway between 2.0 and 2.7 DCPs. The range and specifications are shown below. The standard 1.5mm hex screwdriver (used for 1.5 and 2.0 screws) is required.
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
1.25 Pitch. Din 58812. Use with 3.5mm compression plates to obtain fracture-site compression. Self-tapping screws save time and work extremely well in most cirbumstances especially in the proximal tibia fro TPLO and TTO. Available in 2.0, 2.4, 2.7 and 3.5
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More