Filters and Filtration
Filtered Search Results
MilliporeSigma™ MF-Millipore™ Membrane Filter, 0.45 μm
MF-Millipore™ Membrane Filter are mixed cellulose esters (MCE) membrane, hydrophilic.
| Thickness (Metric) | 150 μm |
|---|---|
| Pore Size | 0.45 μm |
| Disposable | Reusable |
| Flow Rate | 60 mL/min. x cm2 |
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Material | MCE |
| Filter Type | Membrane Filter |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
Fisherbrand™ Disposable PES Filter Units
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Increase cell culture sample protection with Fisherbrand sterile disposable vacuum filter units with PES membranes. The polyethersulfone (PES) membranes have low extractables and low protein binding for use in sterile filtration and clarification of cell culture media and serum.
| Disposable | Single-use |
|---|---|
| Binding Capacity | Low binding |
| Material (Membrane) | PES |
| Certifications/Compliance | Non-pyrogenic per USP Standard Lot-to-Lot |
| Sterility | Sterile |
| Disposable | Reusable |
|---|---|
| Type | Laboratory Filter Holders or Cyclones |
| For Use With (Equipment) | Sterifil Aseptic System |
| Housing Material | Polypropylene |
| Material | Silicone |
| Autoclavable | Autoclavable |
| Sterility | Non-sterile |
Fisherbrand™ Disposable PES Bottle Top Filters
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Increase sample protection with Fisherbrand Sterile Disposable Bottle Top Filters with PES Membranes. The polyethersulfone (PES) membranes have low extractables and low protein binding for use in sterile filtration and clarification of cell culture media and serum.
| Disposable | Single-use |
|---|---|
| Type | Bottle Top Unit |
| Material (Membrane) | PES |
| Certifications/Compliance | Non-pyrogenic per USP Standard Lot-to-Lot |
| Sterility | Sterile |
Corning™ Centrifuge Tube Top Vacuum Filters, CA Membrane
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Filters directly into centrifuge tube minimizing unnecessary transfers. Corning™ Centrifuge Tube Top Filters offer a viewing slot in base that lets you measure volumes as low as 5mL.
| Connectors | Hose |
|---|---|
| Type | Tube Top Vacuum Filter System |
| For Use With (Equipment) | 4.5 cm bottle neck |
| Material (Membrane) | Cellulose Acetate |
| Color | Clear |
| Volume (Metric) | 150 mL |
| No. per Case | 12/Cs. |
| Graduated | Yes |
| Material | Polystyrene |
| No. per Pack | 1/Pk. |
| For Use With (Application) | For the filtration of cell culture media, biological fluids, and other aqueous solutions |
| Sterility | Sterile |
| Filtration Area | 13.6 cm2 |
Fisherbrand™ Vacuum Filter Holders, Borosilicate Glass Bases
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
For use with Fisherbrand™ Vacuum Filter Holders
| For Use With (Equipment) | Vacuum Filter Holder |
|---|---|
| Material | Borosilicate Glass |
Fisherbrand™ Vacuum Filter Holders, Stainless Steel Support Screens
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
For use with Fisherbrand Vacuum Filter Holders
| Material | Stainless Steel |
|---|
MilliporeSigma™ Mitex™ Membrane Filters, Gridded
Unlaminated for extreme chemical or temperature conditions
| Thickness (Metric) | 125 μm |
|---|---|
| Wettability | Hydrophobic |
| Type | Filter Membranes |
| Color | White |
| Material | PTFE |
| Filter Type | Screen Filter |
| For Use With (Application) | Clarification of acids, bases, and cryogenic fluids; clarification of propellants; analysis of hydraulic fluids; RNA isolation. |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
| Membrane Type | Gridded |
| Diameter (Metric) | 50 mm |
|---|---|
| Inlet Style | Stepped Barb (1/4 to 3/8 in.) |
| Housing Material | Polypropylene |
| Material (Membrane) | Polypropylene |
| Volume (Metric) | Up to 1000 mL |
| Quantity | 10 |
| No. per Pack | 10 Pieces |
| Filtration Area | 20.4 cm2 |
Cytiva Whatman™ Grade 91 Wet Strengthened Qualitative Filter Papers - Circles
High wet strength due to the addition of chemically stable resin
| Thickness (Metric) | 205 μm |
|---|---|
| Pore Size | 10 μm |
| Particle Retention | 10 μm |
| Format | Disc |
| Grade | Grade 91 |
| Material | Cellulose |
| Filtration Speed | 70 sec. |
| For Use With (Application) | A general purpose creped filter for less critical routine analysis. Widely used to assay sucrose in cane sugar and within pharmaceutical laboratories for routine filtration. |
Cytiva Whatman™ Grade 91 Wet Strengthened Qualitative Filter Papers - Sheets
High wet strength due to the addition of chemically stable resin
| Thickness (Metric) | 205 μm |
|---|---|
| Pore Size | 10 μm |
| Format | Sheet |
| Quantity | 500 Pk. |
| Grade | Grade 91 |
| Material | Cellulose |
| Filtration Speed | 70 sec. |
| For Use With (Application) | A general purpose creped filter for less critical routine analysis. Widely used to assay sucrose in cane sugar and within pharmaceutical laboratories for routine filtration. |
Corning™ 1000 mL Vacuum Filter/Storage Bottle System
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Vacuum filtration systems use a square filter membrane support system that increases filtration rates with printed funnels to identify membrane type and product number. The system consists of a polystyrene filter funnel joined by an adapter ring to a removable polystyrene storage bottle with a separate sterile polyethylene cap.
| Disposable | Single-use |
|---|---|
| Connectors | Angled Hose |
| Type | Vacuum Filter System |
| Description | Includes square membrane filter, graduated funnel and receiver of clear polystyrene, polyethylene neck adapter, orange HDPE plug seal |
| For Use With (Equipment) | Bottle |
| Volume (Metric) Receiver | 1000 mL |
| Volume (Metric) | 1000 mL |
| Quantity | 12/Cs. |
| Material | Polystyrene |
| Graduations | Yes |
| Sterility | Sterile |
| Filtration Area | 54.5 cm2 |
Spectrum™ Spectra Mesh™ Woven, Nylon Filters
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Consist of individual strands woven into a mesh screen
| Material | Nylon |
|---|
MilliporeSigma™ Mitex™ Membrane Filters, 10 μm
Unlaminated for extreme chemical or temperature conditions
| Pore Size | 10 μm |
|---|---|
| Wettability | Hydrophobic |
| Type | Filter Membranes |
| Color | White |
| Material | PTFE |
| Filter Type | Screen Filter |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
| Membrane Type | Plain |
| Pore Size | 10 μm |
|---|---|
| Flow Rate | 70 mL/min x cm2 |
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Color | White |
| Material | Nylon |
| Filter Type | Net Filter |
| Hydrophobicity | Hydrophilic |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |