Filtration Membrane Discs
Thin, precut membrane rounds for high-throughput, fast filtration of liquid and gas samples. Gridded and non-gridded discs. Various materials including mixed cellulose ester, polycarbonate, PTFE, nylon, and PVDF. For air monitoring/analytical research.
Sizes
Filter membranes are made in a range of diameters, typically designed to fit a specific holder or manifold.
Materials
Filter membrane can be made from cellulose, mixed cellulose esters (MCE), polyvinylidene fluoride (PVDF), polyethersulfone (PES), polyvinyl chloride (PVC), polytetrafluoroethylene (PTFE), nylon, polycarbonate (PC), polyester, polyethylene terephthalate (PET), and polypropylene (PP). Other membrane materials include aluminum oxide, gelatin, porcelain, and glass.
Pore Size
The size of membrane pores determines which particles will be retained by the filter. A pore size of 0.2 µm is small enough to remove microbes from solutions; a 0.45 µm ore size can remove larger particulates.
Color and Grids
White membrane filters may be plain or marked with square grids (outlined in black) that can help with enumerating particles. Gridded or plain black membrane filters may be helpful when filtering light-colored particulates.
Sterility
Filter membranes may be pre-sterilized or may be sterilized using ethylene oxide, gamma irradiation, or autoclaves. The need for sterility is determined by the application, which are many and varied:
- Light microscopy samples
- Cytology sample preparation
- Electron microscopy samples
- Air quality and other environmental monitoring
- Water analysis and water quality testing
- Microbiology colony counting and quality control
- Chemotaxis
- Sterile preparation of buffers, tissue culture media, microbiological media, and other biological fluids
- (11)
- (1)
- (5)
- (76)
- (8)
- (135)
- (9)
- (1)
- (8)
- (1)
- (3)
- (6)
- (184)
- (1)
- (3)
- (22)
- (77)
- (175)
- (51)
- (43)
- (81)
- (1)
- (1)
- (44)
- (14)
- (94)
- (18)
- (1)
- (6)
- (6)
- (26)
- (5)
- (4)
- (3)
- (4)
- (4)
- (10)
- (16)
- (7)
- (54)
- (149)
- (58)
- (2)
- (39)
- (222)
- (44)
- (17)
- (21)
- (8)
- (100)
- (30)
- (18)
- (44)
- (1)
- (32)
- (1)
- (2)
- (13)
- (4)
- (1)
- (1)
- (15)
- (1)
- (6)
- (25)
- (27)
- (1)
- (1)
- (2)
- (73)
- (5)
- (1)
- (1)
- (1)
- (35)
- (1)
- (1)
- (735)
- (146)
- (1)
- (1)
- (3)
- (1)
- (3)
- (1)
- (340)
- (288)
- (6)
- (2)
- (3)
- (130)
- (563)
- (59)
Filtered Search Results
Sartorius Hydrophobic edged Sterile Cellulose Nitrate and Acetate Membrane Filters
Membrane Filters for Colony Counting and Sterility Testing - Cellulose nitrate (cellulose ester), Cellulose acetate and regenerated Cellulose, hydrophobic edged, individually, sterile packaged
| Disposable | Single-use |
|---|---|
| Type | Membrane Filter |
| Format | Disc |
| Color | White |
| Grid Color | Black |
| Quantity | 100/Pk. |
| Filter Type | Membrane Filter |
| Hydrophobicity | Hydrophobic |
| Sterility | Sterile |
Cytiva Whatman™ 0.6 μm Pore Size (ME 26) Mixed Cellulose Ester Membranes, Plain
Whatman™ (ME 26) Mixed Cellulose Ester Membranes are particularly effective in applications requiring higher flow rates and larger volume filtration, including clarification or sterilization of aqueous solutions, particulate analysis and removal, air monitoring, and microbial analysis.
| Pore Size | 0.6 μm |
|---|---|
| Disposable | Single-use |
| Bubble Point | 3.7 bar |
| Flow Rate | 4.8 sec./100 mL/12.5cm² (at Δp = 0.9 bar) |
| Material (Membrane) | ME 26 |
| Grid Color | Plain |
| Material | MCE |
| Surface Type | Plain |
| For Use With (Application) | Filtration, cytology, air monitoring, aqueous HPLC samples, biological assays |
| Autoclavable | Autoclavable |
| Sterility | Non-sterile |
| Gas Flow Rate | 21 sec./100 mL (at Δp = 3 mbar) |
| Pore Size | 0.8 μm |
|---|---|
| Type | Membra Clear Membrane |
| Material | MCE |
| No. per Pack | 100Pack |
Cytiva Whatman™ ME 25 Plain Mixed Cellulose Ester Membranes
Facilitates the counting process and minimizes eye fatigue with color contrast between the surface and the colonies. Whatman™ ME 25 Plain Mixed Cellulose Ester Membranes are characterized by a smooth and more uniform surface.
| Thickness (Metric) | 145 μm |
|---|---|
| Includes | Interleaving paper |
| Pore Size | 0.45 μm |
| Bubble Point | 2.8 bar |
| Flow Rate | 12.5 sec./100 mL/12.5 cm2 |
| Material | Cellulose Acetate, Cellulose Nitrate |
| Autoclavable | Autoclavable |
| Membrane Type | ME25 |
Cytiva Whatman™ Regenerated Cellulose Membranes: Grade RC 55
Consists of pure cellulose without any wetting agents.
| Thickness (Metric) | 75 μm |
|---|---|
| Material | Regenerated Cellulose |
| Hydrophobicity | Hydrophilic |
Sartorius Microsart™ @Filter 250 in Trays
Membrane filters suitable for use in the Microsart @Filter units
| Disposable | Single-use |
|---|---|
| Type | Filter Tip |
| Format | Disc |
| Diameter (Metric) | 47 mm |
| Material (Membrane) | Cellulose Nitrate |
| Sample Volume | 250 mL |
| Material | Cellulose Nitrate |
| Sterility | Sterile |
Cytiva Whatman™ Cellulose Acetate Membranes
Prepares liquid scintillation cocktail for scintillation counter measurements. Whatman™ Cellulose Acetate Membranes are highly heat resistant and can filter hot liquids and hot gases.
| Material | Cellulose Acetate |
|---|---|
| Hydrophobicity | Hydrophilic |
Sartorius Polyamide (Nylon) Membrane Filters
Recommended for particle-removing filtration of water, aqueous solutions and solvents for analytical determination. Sartorius Polyamide (Nylon) Membrane Filters are white, non-sterile filters without grids. Choose from two pore sizes in four diameters. Bulk packed for space and cost savings.
| Thickness (Metric) | 115 μm |
|---|---|
| Disposable | Single-use |
| Type | Membrane Filter |
| Format | Disc |
| Color | White |
| Material | Polyamide |
| Filter Type | Membrane Filter |
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | Recommended for particle removing filtration of water; aqueous solutions and solvents for analytical determination. |
| Autoclavable | Autoclavable |
| Sterility | Non-sterile |
Thermo Scientific Zeta Plus™ LP Series Filter Media Disc
Filter media is composed of inorganic filter aid cationic resin and is designed to be very low in extractables. This LP media is completely free of asbestos and glass microfibre.
| Disposable | Single-use |
|---|---|
| Type | Filtration Disc |
| Format | Disc |
| Length (English) | 11.5 in. |
| Quantity | 100/Cs. |
| Material | Cellulose |
| Sterility | Non-sterile |
Sartorius Gridded Nonsterile Cellulose Nitrate Membrane Filters: 0.2μm Pore Size
The non-sterile membrane filters are made of cellulose nitrate (cellulose mixed ester), cellulose acetate or regenerated cellulose. They can be used for colony counting, particle testing and microscopy. Choose between gridded or non-gridded, membranes, either with or without hydrophobic edge.
| Pore Size | 0.2 μm |
|---|---|
| Disposable | Single-use |
| Type | Membrane Filter |
| Format | Disc |
| Material (Membrane) | Cellulose Nitrate |
| Color | White |
| Grid Color | Black |
| Material | Cellulose Nitrate |
| Filter Type | Membrane Filter |
| Sterility | Non-sterile |
MilliporeSigma Millipore Polypropylene Membrane Filter, 0.2 μm
Hydrophobic polypropylene filters in 25, 47, and 90 mm sizes offer reliable aqueous filtration, low extractables, and consistent flow for lab use
| Sterility | Non-sterile |
|---|
Sartorius Gridded Nonsterile Cellulose Nitrate Membrane Filters: 0.65μm Pore Size
The non-sterile membrane filters are made of cellulose nitrate (cellulose mixed ester), cellulose acetate or regenerated cellulose. They can be used for colony counting, particle testing and microscopy. Choose between gridded or non-gridded, membranes, either with or without hydrophobic edge.
| Pore Size | 0.7 μm |
|---|---|
| Disposable | Single-use |
| Type | Membrane Filter |
| Format | Disc |
| Material (Membrane) | Cellulose Nitrate |
| Quantity | 100/Pk. |
| Material | Cellulose Nitrate |
| Filter Type | Membrane Filter |
| For Use With (Application) | For colony count; sterility testing; particle count; microscopy |
| Sterility | Non-sterile |
MilliporeSigma™ S-Pak™ Sterile Membrane Filter Kit
Made from mixed esters of cellulose and have been optimized for MF method microbiological analysis of water or other liquids
| Pore Size | 0.5 μm |
|---|---|
| Diameter (Metric) | 47 mm |
| Color | White |
| For Use With (Application) | For microbiological analysis |
| Sterility | Sterile |
Sartorius Gridded Nonsterile Cellulose Nitrate Membrane Filters: 0.45μm Pore Size
The Nonsterile Membrane Filters are made of cellulose nitrate (cellulose mixed ester), cellulose acetate or regenerated cellulose. They can be used for colony counting, particle testing and microscopy. Choose between gridded or non-gridded, membranes, either with or without hydrophobic edge.
| Pore Size | 0.45 μm |
|---|---|
| Disposable | Single-use |
| Type | Membrane Filter |
| Format | Disc |
| Material (Membrane) | Cellulose Nitrate |
| Material | Cellulose Nitrate |
| Filter Type | Membrane Filter |
| For Use With (Application) | For Colony Count, Sterility Testing, Particle Count, Microscopy |
| Sterility | Non-sterile |
Cytiva Whatman™ 0.8 μm Pore Size (ME 27) Mixed Cellulose Ester Membranes, White/Black Grid
Whatman™ (ME 27) Mixed Cellulose Ester Membranes, White/Black Grid are particularly effective in applications requiring higher flow rates and larger volume filtration. Supplied with clearly defined grid lines at regularly spaced intervals to assist in microbiological colony counting.
| Pore Size | 0.8 μm |
|---|---|
| Diameter (English) | 1.85 in. |
| Material (Membrane) | ME 27 |
| Color | White |
| Grid Color | Black |
| Quantity | 100 Pk. |
| Material | MCE |
| For Use With (Application) | Filtration, cytology, air monitoring, aqueous HPLC samples, biological assays |
| Sterility | Sterile |
| Thickness (Metric) | 140 μm |
| Bubble Point | 1.3 bar |
| Flow Rate | 2.8 sec./100 mL/12.5 cm2 (at Δp = 0.9 bar) |
| Diameter (Metric) | 47 mm |
| Thickness (English) | 0.006 in. |
| Autoclavable | Autoclavable |
| Size (Metric) Grid | 3.1 mm |