Filtration Membrane Discs
Thin, precut membrane rounds for high-throughput, fast filtration of liquid and gas samples. Gridded and non-gridded discs. Various materials including mixed cellulose ester, polycarbonate, PTFE, nylon, and PVDF. For air monitoring/analytical research.
Sizes
Filter membranes are made in a range of diameters, typically designed to fit a specific holder or manifold.
Materials
Filter membrane can be made from cellulose, mixed cellulose esters (MCE), polyvinylidene fluoride (PVDF), polyethersulfone (PES), polyvinyl chloride (PVC), polytetrafluoroethylene (PTFE), nylon, polycarbonate (PC), polyester, polyethylene terephthalate (PET), and polypropylene (PP). Other membrane materials include aluminum oxide, gelatin, porcelain, and glass.
Pore Size
The size of membrane pores determines which particles will be retained by the filter. A pore size of 0.2 µm is small enough to remove microbes from solutions; a 0.45 µm ore size can remove larger particulates.
Color and Grids
White membrane filters may be plain or marked with square grids (outlined in black) that can help with enumerating particles. Gridded or plain black membrane filters may be helpful when filtering light-colored particulates.
Sterility
Filter membranes may be pre-sterilized or may be sterilized using ethylene oxide, gamma irradiation, or autoclaves. The need for sterility is determined by the application, which are many and varied:
- Light microscopy samples
- Cytology sample preparation
- Electron microscopy samples
- Air quality and other environmental monitoring
- Water analysis and water quality testing
- Microbiology colony counting and quality control
- Chemotaxis
- Sterile preparation of buffers, tissue culture media, microbiological media, and other biological fluids
- (11)
- (1)
- (1)
- (92)
- (8)
- (150)
- (9)
- (8)
- (4)
- (6)
- (171)
- (1)
- (3)
- (22)
- (62)
- (46)
- (21)
- (86)
- (1)
- (1)
- (41)
- (14)
- (95)
- (5)
- (2)
- (22)
- (2)
- (1)
- (3)
- (4)
- (4)
- (3)
- (11)
- (2)
- (41)
- (121)
- (52)
- (3)
- (21)
- (204)
- (46)
- (9)
- (24)
- (8)
- (81)
- (10)
- (20)
- (49)
- (1)
- (16)
- (2)
- (6)
- (1)
- (6)
- (1)
- (2)
- (12)
- (28)
- (1)
- (1)
- (2)
- (53)
- (5)
- (1)
- (1)
- (21)
- (1)
- (509)
- (140)
- (1)
- (1)
- (3)
- (1)
- (3)
- (1)
- (390)
- (1)
- (6)
- (3)
- (137)
- (378)
- (3)
Filtered Search Results

MilliporeSigma™ MF-Millipore™ Membrane Filter, 5 μm

MF-Millipore™ Membrane Filter are mixed cellulose esters (MCE) membrane, hydrophilic.

Pore Size | 5 μm |
---|---|
Disposable | Reusable |
Color | White |
Material | MCE |
Sterility | Non-sterile |
Thickness (Metric) | 135 μm |
Bubble Point | ≥0.42 bar, air with water |
Flow Rate | 580 mL/min. x cm2 |
Wettability | Hydrophilic |
Type | Filter Membranes |
Format | Disc |
Filter Type | Membrane Filter |
Autoclavable | Not Autoclavable |
Membrane Type | Plain |
Gas Flow Rate | 32 L/min./cm2 |
MilliporeSigma™ MF-Millipore™ Membrane Filter, 0.22 μm

MF-Millipore™ Membrane Filter is a 13 mm diameter, mixed cellulose esters (MCE) membrane, hydrophilic.

Pore Size | 0.22 μm |
---|---|
Disposable | Reusable |
Color | White |
Material | MCE |
Hydrophobicity | Hydrophilic |
Sterility | Non-sterile |
Thickness (Metric) | 150 μm |
Bubble Point | ≥3.52 bar, air with water |
Flow Rate | 18 mL/min. x cm2 |
Wettability | Hydrophilic |
Type | Filter Membranes |
Format | Disc |
Filter Type | Membrane Filter |
Autoclavable | Not Autoclavable |
Gas Flow Rate | 2 L/min./cm2 |
MilliporeSigma™ Isopore™ Membrane Filters, 5 μm

Use for analyses of airborne contaminants and other particles using optical or electron microscopy. Isopore™ Polycarbonate Membrane Filters have a smooth, glass-like surface for clearer sample observation. Available in a variety of pore sizes/flow rates, diameters and colors.

Pore Size | 5 μm |
---|---|
Wettability | Hydrophilic |
Type | Filter Membranes |
Color | White |
Material | Polycarbonate |
Filter Type | Screen Filter |
Hydrophobicity | Hydrophilic |
For Use With (Application) | Air Analysis; Cell Biology; Cell Culture; Bioassays; Cytology; Environmental Analysis; Epifluorescence. |
Autoclavable | Not Autoclavable |
Sterility | Non-sterile |
Gas Flow Rate | 50.0 L/min/cm2 |
MilliporeSigma™ MF-Millipore™ Membrane Filter, 1.2 μm

Mixed cellulose esters (MCE) membrane, hydrophilic

Pore Size | 1.2 μm |
---|---|
Flow Rate | 270 mL/min x cm2 |
Wettability | Hydrophilic |
Type | Filter Membranes |
Color | White |
Material | MCE |
Hydrophobicity | Hydrophilic |
Autoclavable | Not Autoclavable |
Sterility | Non-sterile |
Membrane Type | Plain |
MilliporeSigma™ MF-Millipore™ Membrane Filter, 8 μm

Mixed cellulose esters (MCE) membrane, hydrophilic

Pore Size | 8 μm |
---|---|
Flow Rate | 620 mL/min x cm2 |
Wettability | Hydrophilic |
Type | Filter Membranes |
Color | White |
Material | MCE |
Hydrophobicity | Hydrophilic |
For Use With (Application) | For use in air monitoring; Fluid monitoring; Particle collection and analysis; QC of fluid holding tanks. |
Autoclavable | Not Autoclavable |
Sterility | Non-sterile |
MilliporeSigma™ Isopore™ Membrane Filters, 3 μm

Use for analyses of airborne contaminants and other particles using optical or electron microscopy. Isopore™ Polycarbonate Membrane Filters have a smooth, glass-like surface for clearer sample observation. Available in a variety of por

Pore Size | 3.0 μm |
---|---|
Wettability | Hydrophilic |
Type | Filter Membranes |
Color | White |
Material | Polycarbonate |
Filter Type | Screen Filter |
Hydrophobicity | Hydrophilic |
For Use With (Application) | Air Analysis; Cell Biology; Cell Culture; Bioassays; Cytology; Environmental Analysis; Epifluorescence. |
Autoclavable | Not Autoclavable |
Sterility | Non-sterile |
MilliporeSigma™ MF-Millipore™ Membrane Filter, 0.8 μm, Gridded

Mixed cellulose esters (MCE) membrane, hydrophilic

Thickness (Metric) | 150 μm |
---|---|
Pore Size | 0.8 μm |
Flow Rate | 190 mL/min x cm2 |
Wettability | Hydrophilic |
Type | Filter Membranes |
No. per Case | 100Pack |
Material | MCE |
Autoclavable | Not Autoclavable |
Sterility | Non-sterile |
Pore Size | 5 μm |
---|---|
Bubble Point | ≥0.2 bar, air with water |
Flow Rate | >15.4 mL/min x cm2 |
Wettability | Hydrophilic |
Type | Filter Membranes |
Color | White |
No. per Case | 100Pack |
Quantity | 100/Pk. |
Material | PVDF |
Filter Type | Screen Filter |
Hydrophobicity | Hydrophilic |
Autoclavable | Not Autoclavable |
Sterility | Non-sterile |
MilliporeSigma™ Fluoropore™ Membrane Filters, 0.22 μm

Hydrophobic membrane with laminated backing for easier handling

Pore Size | 0.22 μm |
---|---|
Flow Rate | 24 mL/min x cm2 |
Wettability | Hydrophobic |
Type | Filter Membranes |
Color | White |
Material | PTFE |
Filter Type | Screen Filter |
Hydrophobicity | Hydrophobic |
Autoclavable | Not Autoclavable |
Sterility | Non-sterile |
MilliporeSigma™ Isopore™ Membrane Filters, 0.8 μm

Use for analyses of airborne contaminants and other particles using optical or electron microscopy. Isopore™ Polycarbonate Membrane Filters have a smooth, glass-like surface for clearer sample observation. Available in a variety of pore sizes/flow rates, diameters and colors.

Pore Size | 0.8 μm |
---|---|
Disposable | Reusable |
Color | White |
Material | Polycarbonate |
Hydrophobicity | Hydrophilic |
For Use With (Application) | Air Analysis, Cell Biology, Cell Culture, Bioassays, Cytology, Environmental Analysis, Epifluorescence |
Sterility | Non-sterile |
Bubble Point | 8.5 psi |
Wettability | Hydrophilic |
Type | Filter Membranes |
Format | Disc |
Filter Type | Screen Filter |
Autoclavable | Not Autoclavable |
Gas Flow Rate | 20.0 L/min./cm2 |
MilliporeSigma™ MF-Millipore™ Membrane Filter, 0.65 μm

MF-Millipore™ Membrane Filter composed of mixed cellulose esters (MCE) membrane, hydrophilic.

Pore Size | 0.65 μm |
---|---|
Disposable | Reusable |
Flow Rate | 140 mL/min. x cm2 |
Wettability | Hydrophilic |
Type | Filter Membranes |
Format | Disc |
Color | White |
Material | MCE |
Filter Type | Membrane Filter |
Hydrophobicity | Hydrophilic |
Autoclavable | Not Autoclavable |
Sterility | Non-sterile |
Cytiva Whatman™ Polyester Drain Discs

Provides a flat surface to eliminate filter tearing or rupturing. Whatman™ Polyester Drain Discs are used to support membrane filters. They are available in a variety of diameters for use in a range of devices.

Thickness (Metric) | 100 μm |
---|---|
Material | Polyester |
Cytiva Whatman™ 47 mm Nuclepore™ Polycarbonate Track-Etched Membranes
Manufactured from high-quality polycarbonate film and track-etched for high pore size precision. Whatman™ 47mm Nuclepore™ Polycarbonate Hydrophilic Membranes combine high flow rates and chemical and thermal resistance with sharply defined pores, making them suitable for microscopy, cytology, parasitology, and certain air and oceanography analyses.

Flow Rate | High |
---|---|
Diameter (Metric) | 47 mm |
Material | Nucleopore Polycarbonate |
Hydrophobicity | Hydrophilic |
For Use With (Application) | Epifluorescence microscopy, environmental analysis, cell biology |
Pore Size | 0.2 μm |
---|---|
No. per Case | 100 Pk. |
Quantity | 100 Pk. |
Material | Nylon |
Hydrophobicity | Hydrophilic |
For Use With (Application) | Clarifying aqueous or organic solutions prior to HPLC analysis. |
Sterility | Non-sterile |
Bubble Point | 40 psi |
Flow Rate | 15 (at 690 Mbar (10 psi)) |
Wettability | Hydrophilic |
Type | Filter Membranes |
Format | Disc |
Filter Type | Screen Filter |
Autoclavable | Not Autoclavable |