
Syringeless and Syringe Filters
- (2)
- (8)
- (16)
- (376)
- (9)
- (94)
- (1)
- (488)
- (1)
- (1)
- (15)
- (16)
- (2)
- (5)
- (23)
- (1)
- (15)
- (1)
- (3)
- (5)
- (2)
- (1)
- (3)
- (3)
- (26)
- (3)
- (1)
- (1)
- (1)
- (14)
- (4)
- (1)
- (2)
- (8)
- (76)
- (4)
- (19)
- (4)
- (4)
- (1)
- (44)
- (1)
- (19)
- (2)
- (150)
- (110)
- (3)
- (1)
- (115)
- (43)
- (52)
- (128)
- (28)
- (4)
- (2)
- (1)
- (8)
- (2)
- (5)
- (4)
- (6)
- (11)
- (73)
- (25)
- (635)
- (174)
- (9)
- (524)
- (6)
- (15)
- (1)
- (4)
- (2)
- (12)
- (1)
- (6)
- (2)
- (5)
- (158)
- (8)
- (12)
- (1)
- (8)
- (82)
- (3)
- (1)
- (8)
- (2)
- (17)
- (2)
- (1)
Filtered Search Results

MilliporeSigma™ Millex™-GP Sterile Syringe Filter Units with PES Membrane, 0.22 μm (Research Use Only)
Ready-to-use, syringe-driven units designed for sterilizing and clarifying sterile solutions.

Pore Size | 0.22 μm |
---|---|
Disposable | Single-use |
Temperature (English) Operating | 113°F |
Housing Material | Hydrophilic PES |
Material (Membrane) | PES |
Color | Green |
Volume (Metric) | <10 mL |
Pressure Rating | 145 psi |
For Use With (Application) | Sterilization of tissue culture media, protein solutions or aqueous solutions;Low Protein Binding |
Sterility | Sterile |
Type | Modified Acrylic Syringe Filter |
Outlet Style | Male Luer Slip |
Diameter (Metric) | 3.3 cm |
Inlet Style | Female Luer Lock |
Tip Material | Modified Acrylic |
Temperature Range (English) | 113°F |
Temperature Range (Metric) | 45°C |
Temperature (Metric) Operating | 45°C |
Autoclavable | Not Autoclavable |
Hold up Volume (After Air Purge) | <100 μL |
Thermo Scientific Chromatography Choice™ Nylon Syringe Filters
Use Thermo Scientific™ Choice™ Nylon Syringe Filters as the economic option for most general laboratory filtration, and for filtration of most HPLC samples.

Disposable | Single-use |
---|---|
Type | Syringe Filter |
Housing Material | Solvent Resistent, Low-Extractable Polypropylene |
Material (Membrane) | Nylon |
Quantity | 100/Pk. |
Pressure Rating | 90 psi |
For Use With (Application) | HPLC, SPE |
Prefilter | No |
Sterility | Non-sterile |
Product Line | Choice |
Outlet Style | Male Leur-Slip |
---|---|
Diameter (Metric) | 33 mm |
Inlet Style | Female Luer Lock |
Housing Material | Acrylic |
Material (Membrane) | PES |
Quantity | 50/Pk. |
Sterility | Sterile |
Cytiva Whatman™ Puradisc 25mm PTFE Syringe Filters

Contains hydrophobic membrane that is chemically stable and inert. Whatman™ Puradisc 25mm PTFE Syringe Filters exhibit low protein binding, and its main application is filtration of non-aqueous samples.

Type | Syringe Filter |
---|---|
Dimensions (L x W x H) | 22.9 x 28.4 mm |
Outlet Style | Male Luer |
Diameter (Metric) | 25 mm |
Inlet Style | Female Luer Lock |
Material (Membrane) | PTFE |
Volume (Metric) | Up to 100 mL |
Pressure Rating | 5.2 bar (75 psi) |
Material | PTFE |
For Use With (Application) | For HPLC, TLC, and GC sample clarification; HPLC solvent filtration |
Sterility | Non-sterile |
Filtration Area | 4.2 cm2 |
Fisher Scientific Basix™ Syringe Filters, Nylon, Sterile
Attach to the end of syringes and filter contents as it is being forced out. Fisherbrand™ Basix™ Syringe Filters, Nylon, Sterile offers high sample throughput.

Diameter (Metric) | 25 mm |
---|---|
Housing Material | Acrylic |
Material (Membrane) | Nylon |
Sterility | Sterile |
MilliporeSigma™ Medical Millex™-GP Syringe Filter Unit, 0.22 μm

Ready-to-use, syringe-driven units designed for sterilizing and clarifying sterile solutions

MilliporeSigma™ Millex™ Syringe Filter, Durapore™ (PVDF), 0.45 μm

Remove particulates, reduce signal-to-noise ratios and maintain flat baselines. Millex™ Nonsterile 33 mm Syringe Filters are constructed of polyethylene housing with Durapore™ membranes for preparing samples for analysis. Available in two pore sizes.

Pore Size | 0.45 μm |
---|---|
Disposable | Single-use |
Filter Code | HV |
Housing Material | Polypropylene |
Material (Membrane) | PVDF |
Volume (Metric) | <100 mL |
Color Code | Yellow |
For Use With (Application) | Analytical sample prep |
Sterility | Non-sterile |
Filtration Area | 4.5 cm2 |
Type | Syringe Filter |
Diameter (Metric) | 33 mm |
Diameter (Metric) Filter | 33 mm |
Filter Type | Syringe Filter |
Hold up Volume (After Air Purge) | ≤80 μL |
Product Line | Millex™ |
Thermo Scientific Choice™ PTFE (Hydrophilic) Syringe Filters
Use Choice PTFE Hydrophilic Syringe Filters to filter aggressive organic, highly basic or hot solutions. They can filter aqueous solutions without pre-wetting.

Disposable | Single-use |
---|---|
Type | Syringe Filter |
Housing Material | Solvent Resistent, Low-Extractable Polypropylene |
Material (Membrane) | PTFE (Hydrophilic) |
Quantity | 100/Pk. |
Pressure Rating | 90 psi |
For Use With (Application) | HPLC, SPE |
Prefilter | No |
Sterility | Non-sterile |
Product Line | Choice |
Thermo Scientific™ Titan3™ PTFE (Hydrophilic) Syringe Filters
Ensure cleaner sample extracts by removing interfering materials and fine particles prior to injection with these robust hydrophilic PTFE syringe filters.

Disposable | Single-use |
---|---|
Type | Syringe Filter |
Housing Material | Polypropylene |
Material (Membrane) | PTFE (Hydrophilic) |
Certifications/Compliance | Titan3 Polypropylene Syringe Filter Housings Meet The Requirements of 21 CFR 177.1520. |
For Use With (Application) | Sample Filtration: aggressive organic, highly basic, or hot solutions, transducer protectors; aqueous solutions after prewetting with an alcohol |
Prefilter | No |
Sterility | Non-sterile |
Product Line | Titan3 |
Cytiva Whatman™ GD/X Glass Fiber (GF) Syringe Filters

Processes three to seven times more sample volume than filters without prefilter. Whatman™ GD/X Glass Fiber (GF) Syringe Filters are specifically designed for filtration of viscous or otherwise hard-to-filter samples with high solids content.

Disposable | Single-use |
---|---|
Type | Syringe Filter |
Dimensions (L x W x H) | 21.6 x 29.8 mm |
Outlet Style | Male Luer |
Inlet Style | Female Luer Lock |
Housing Material | Pigment free polypropylene (PP) |
Volume (Metric) | ≤10 mL |
Filter Type | Syringe Filter |
Fisherbrand™ Syringe Filters - Sterile
Low hold-up volume helps you to recover virtually all of your sample after filtering

Type | Syringe Filter |
---|---|
Hold up Volume (After Air Purge) | Low |
MilliporeSigma™ Millex™-HP Sterile Polyethersulfone Syringe Filter Units, 0.45 μm (Research Use Only)
Ready-to-use, syringe-driven units designed for sterilizing and clarifying sterile solutions.

Pore Size | 0.45 μm |
---|---|
Disposable | Single-use |
Temperature (English) Operating | 113°F |
Housing Material | Hydrophilic PES |
Material (Membrane) | PES |
Color | Green |
Volume (Metric) | 100 mL |
Pressure Rating | 145 psi |
For Use With (Application) | Sterilization of tissue culture media, protein solutions or aqueous solutions;Low Protein Binding |
Sterility | Sterile |
Type | Syringe Filter |
Outlet Style | Male Luer Slip |
Diameter (Metric) | 3.3 cm |
Inlet Style | Female Luer Lock |
Tip Material | Modified Acrylic |
Temperature Range (English) | 113°F |
Temperature Range (Metric) | 45°C |
Temperature (Metric) Operating | 45°C |
Autoclavable | Not Autoclavable |
Hold up Volume (After Air Purge) | <0.1 mL |
Fisher Scientific Basix™ Syringe Filters, PES, Sterile
Attach to the end of syringes and filter contents as it is being forced out. Fisherbrand™ Basix™ Syringe Filters, PES, Sterile offers high sample throughput.
Diameter (Metric) | 25 mm |
---|---|
Housing Material | Acrylic |
Material (Membrane) | PES |
Sterility | Sterile |
Fisher Scientific Basix™ Syringe Filters, PTFE, Non-Sterile
Attach to the end of syringes and filter contents as it is being forced out. Fisherbrand™ Basix™ Syringe Filters, PTFE, Non-Sterile offers high sample throughput.

Housing Material | Polypropylene |
---|---|
Material (Membrane) | PTFE (Hydrophobic) |
Sterility | Non-sterile |
Fisher Scientific Basix™ Syringe Filters, Nylon, Non-Sterile
Attach to the end of syringes and filter contents as it is being forced out. Fisherbrand™ Basix™ Syringe Filters, Nylon, Non-Sterile offers high sample throughput.

Housing Material | Polypropylene |
---|---|
Material (Membrane) | Nylon |
Sterility | Non-sterile |