Microscope Accessories and Replacement Parts
General accessories and parts for use with microscopes. Products include lens oil, lens cleaner, slide dispensers, microscope covers, vessel holders, light cubes, and flow cells.
Many parts of your microscope can be updated or replaced including microscope lamps, lenses, and eyepieces. Replacement lamps, light sources, and power cords can extend the working lives of your microscopy equipment. New or replacement objectives and lenses can help increase the total magnification available with your microscope.
Add greater magnification or exchange your eyepiece for one with a reticule to more easily estimate the sizes of the items being viewed.
Replace or update your mechanical stage or clamps or add cell culture vessel adapters to facilitate specimen positioning.
Condensers can also be replaced, and conversion kits are available to add phase contrast, polarization, fluorescence, or other capabilities to your current system.
Some microscopes can be adapted for use with still or video cameras. Look for cameras and adapters designed for your specific microscope brand. Film and documentation-related products may also be available to support your record-keeping.
Temporary, semi-permanent, and more long-term slide storage options include:
- Slide racks that securely hold slides during staining procedures
- Folding fiberboard or plastic slide holders with horizontal indentations that keep microscope slides in place
- Slide storage boxes with vertical dividers; made from fiberboard, plastic, and wood and available in multiple sizes
- Slide holders and mailers for transporting slides safely
- Slide storage systems and cabinets for large quantities of slides or archival storage
- (1)
- (5)
- (4)
- (4)
- (2)
- (1)
- (1)
- (6)
- (3)
- (1)
- (5)
- (4)
- (9)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (16)
- (5)
- (6)
- (2)
- (1)
- (1)
- (2)
- (1)
- (9)
- (1)
- (1)
- (1)
- (2)
- (4)
- (1)
- (1)
- (15)
- (3)
- (4)
- (1)
- (3)
- (2)
- (1)
- (5)
- (2)
- (1)
- (1)
- (1)
- (11)
- (2)
- (1)
- (2)
- (1)
- (1)
- (3)
- (1)
- (2)
- (6)
- (1)
- (5)
- (1)
- (2)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (14)
- (1)
- (1)
- (1)
- (2)
- (1)
- (3)
- (1)
- (1)
- (5)
- (5)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
Filtered Search Results
Electron Microscopy Sciences TEM Screen Recoating Siemens Outer, Crescent, Outer Field
For optimum viewing, fluorescent screens should be recoated regularly. Viewing screens are easily damaged by the electron beam, especially at high accelerating voltages where knock-on damage can be severe. A proprietary process where 1 to 2 micron particles of phosphor are deposited on the screen and produce the highest possible resolution.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Veco Square Center Reference 200 mesh Nickel Grid
Veco Grids offer superior handling characteristics. Plus, with a 0.8 mil thickness, Veco Grids are the most rigid grids available. 3.05 mm diameter.
Grid: Nickel
Pitch: 125 µm
Hole: 85 µm
Bar: 40 µm
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences EMS Tungsten Loop Filament Rebuilt, ISI, ABT, Topcon
Filament rebuilding includes reconditioning of the base; cleaning and/or replacement of necessary parts; Installment of new filament tip; Pre-centering; Vacuum normalizing; and Microscopic inspection.
Use: ISI Instruments, ABT, Topcon
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Formvar Support Film 5-6 nm thick on 2 X 1 mm Slot Grid Copper Grid
A thin film of pure formvar resin coats the shiny side of a slotted grid. Coated grids are optically checked and batch tested in the electron microscope. Packed in grid storage box. Standard coating is 5 to 6 nm thick.
Grid: Copper
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Enzo Life Sciences NS-2028 (1mg). CAS: 204326-43-2
A potent and selective, cell-permeable inhibitor of nitric oxide (NO)-sensitive soluble guanylyl cyclase (sGC). Inhibition is irreversible. Inhibits also the basal, the YC-1 and the coenhanced sGC activity. Complete inhibition of NO-induced relaxation in vascular and nonvascular smooth muscle at 1μM. Alternative name: 4H-8-Bromo-1,2,4-oxadiazolo(3,4-d)benz(b)(1,4)oxazin-1-one. Formula: C9H5BrN2O3. MW: 269.1. Purity: ≥98% (TLC). Appearance: White to off-white crystalline powder. Solubility: Soluble in DMSO or 100% ethanol; insoluble in water. Long Term Storage: -20°C. Handling: Protect from moisture.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences PremaDisk Diamond Grinding Disc SH Hard Bond, 6 µm Particles, 250 mm diameter
PremaDisk Flexible Diamond Grinding Discs offer superior surface finishes that are usually only seen in lapping processes.
The SM disc is a medium-hard resin bond base for fine grinding and polishing of metals, ceramics and glass.
The SH disc is a hard resin bond base for applications where a very sharp edge must be maintained on the workpiece.
Both discs increase productivity by combining optimum surface quality, removal rates, and tool life in the same process.
Particles: 6 µm
Diameter: 250 mm
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Walton & Beckett Graticule G25, 19 mm,
The Walton and Beckett graticule is for counting fibrous dust (asbestos or glass fibers) and particularly where the majority of fibers to be counted are shorter than 5 microns. The circle is divided into four by two diametrical lines scaled in units of 5 and 3 microns respectively. 3 and 5 microns are the critical measurements of fiber lengths and diameters used in fiber counting. Walton and Beckett include shapes with an aspect ratio of 3:1 or 5:1 for comparing to fibers.
IMPORTANT NOTE: The circle on these Walton & Beckett graticules must represent 100 microns at the stage and each one must be manufactured to the individual instrument. Based on the G22. The G25 is produced by the Institute of Occupational Health.
Size: 19 mm
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences CoverWell™ Perfusion Chamber 1 well with 1550 µl volume
CoverWell Perfusion Chambers allows up to 16 different specimens on one coverglass. "Press-to-Seal" covers form water-tight, multiwall cell incubation or cytochemistry chamber when pressed to coverslips or microscope slides. Reagents can be quickly added and removed through dual access ports (1.5 mm Dia) without disturbing or cross-contaminating specimens in adjacent wells. Chambers are removable for permanent mounting of specimens. CoverWell chambers are made from medical grade silicone bonded to clear, UV transparent plastic.
Volume: 1550 µl
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Gilder Thin Bar Square 400 mesh Gold Grid
Thin Bar Grids have been developed using a new technology to produce ultra-fine grids with thinner cross bars than regular grids. The result is equally firm specimen support but with 40% more open area for viewing maximum specimen surface area. 3.05 diameter, 0.8 mil thickness.
Grid: Gold
Pitch: 62 µm
Hole: 54 µm
Bar: 8 µm
:
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Gilder Standard Square 300 mesh Cu/Pd Grid
A reliable support specimen grid source. Features well-defined grid bars, maximum open area, and a matt/shiny side. Each grid is individually inspected. 3.05 mm diameter, 0.7 mil (18 um) thickness.
Grid: Copper/Palladium
Pitch: 83 µm
Hole: 58 µm
Bar: 25 µm
:
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Veco Square Mesh Oyster Grid D75, Nickel
Veco Grids offer superior handling characteristics. Plus, with a 0.8 mil thickness, Veco Grids are the most rigid grids available. 3.05 mm diameter.
Material: Nickel
Pitch: 333 µm
Holes: 283 µm
Bar: 50 µm
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Micron Optics 6V/30W QUARTZ HALOGEN BULB
This item has a minimum qty of 6 per supplier requirements.
6V/30W QUARTZ HALOGEN BULB
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Metallurgical Graticle G54, 21mm, ASTM 24
Standard pattern discs for metallurgical stereometric analysis of grain size in polished metal sections. ASTM 24 point circular grid, glass sandwich.
Size: 21mm
Method: ASTM 24
Surface: Glass sandwich
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Square Grid Graticle NE10, 16mm, 0.5 mm pitch
Simple grids are convenient for making sketches of the obseved specimen on graph paper. They are also useful for particle counting. Grid (net) 0.5mm pitch.
Size: 16mm
Divisions: 0.5 mm pitch
Surface: Chrome image
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences TEM Screen Recoating Siemens Final IA, 102, Central Field
For optimum viewing, fluorescent screens should be recoated regularly. Viewing screens are easily damaged by the electron beam, especially at high accelerating voltages where knock-on damage can be severe. A proprietary process where 1 to 2 micron particles of phosphor are deposited on the screen and produce the highest possible resolution.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More