General Spectrometer Accessories
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (5)
- (5)
- (5)
- (1)
- (14)
- (1)
- (2)
- (4)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (10)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (3)
Filtered Search Results
Glass Expansion Quartz Torch with 1.5mm Injector for Agilent7500
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Quartz Torch, single-piece, 1.5 mm id injector, for aqueous and less-volatile organic solvent analysis with Agilent 7500 ICP-MS. Standard quartz torch suitable for routine aqueous and less-volatile organic solvent applications but not inert to samples containing hydrofluoric acid (HF).Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion DuraMist DC Nebulizer 1mL/min, Includes NFT-16-50 UniFit Connector with 0.50mm ID x 1.6mm OD x 700mm long tubing (1 piece), and 70-803-1070 Gas Fitting with Ratchet Nebulizer connector
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
DuraMist DC Nebulizer 1.0mL/min, includes UniFit Connector with 0.50mm ID x 1.6mm OD x 700mm long tubing (1 pc) and DC Gas Fitting Type 21 with ratchet connector (1 pc). Compatible with Perkin Elmer Optima ICP-OES.Optimum nebulizer gas flow rate is 0.7L/min & sample flow rate is 1.0mL/min. Recommended not to exceed optimum 1.0mL/min sample flow rate; however, lower gas & sample flow rates are OK. The backpressure should read ~40 psi at 0.7L/min gas flow rate. DuraMist is an economical inert nebulizer for high-precision analysis & the highest tolerance to TDS, up to 30%. Made from PEEK, it tolerates up to 5% HF.Replacement parts include P/Ns 502702959 and 70-803-1070.Recommend nebulizer maintenance tools are Fluka RBS25 (P/N NC9000117) & Eluo Nebulizer Cleaning Tool (P/N 501907353). When nebulizer is not in use, best to store in the provided hard plastic case.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Perkin Elmer US LLC 2.0 mm I.D. Quartz Ball Joint Injector for ELAN/NexION 300/350
This Quartz Ball Joint Injector is included in the NexION 300/350Q/X/D Consumables Kit (N8140513), NexION 300/350S Consumables Kit (N8140514), ELAN DRC II Spares Kit (N8120611), and the Quartz Cyclonic Sample Introduction System for ELAN (N8120519).
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Perkin Elmer US LLC 1.0 mL Sample Loop, 0.8 mm ID, connect to ports #1 and #4
1mL Sample Loop, connect to ports nos 1 and 4
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Perkin Elmer US LLC Replacement Spring for Autosampler
Complete installation requires two springs.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Cole-Parmer NEBULIZER CLEANING WIRES 3/PK
Flame Photometer Nebulizer Cleaning Wires; 3/Pk
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Thermo Scientific Y connector 0.5mm PEEK [quantity]
Y shaped fluidic connector with 0.5 mm inner diameter made of polyetheretherketone plastic splits and combines fluid flow enabling flexible microfluidics routing and is commonly used in analytical instrumentation setups.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Premier Lab Supply Mylar 6.0μm (0.24mil) Sheets – PN# TF-160-345
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Mylar film 6.0μm (0.24mil) Sheets with Dimensions: 3” x 3” (76 x 76mm) (PN# TF-160-345) – Mylar has excellent tinsel strength and chemical resistance, and is well-suited for light elements in thinner gauges. 500 per box.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Lascar Electronics Inc Temperature monitor with email alerts
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Wireless Alert TP is a battery-powered temperature sensor that sends a warning email if a user-set level is reached. Simply select your temperature limits, add an email address and connect to your Wi-Fi network using the Wireless Alert mobile app.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion PVC Pump Tube 3tag, 95mm spacing, 0.25mm ID, Orange/Blue (PKT 12)
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
PVC Pump Tube 3tag (95mm spacing) 0.25mm ID Orange/Blue (PKT 12).Tag Colors: Orange/BlueID mm: 0.25Wall Thickness mm: 0.86OD mm 1.97Overall Length: 455mm (95mm spacing between tags)Number of Tubes Per Pack: 12Physical Properties: Thermoplastic, PVC based material with plasticizerMaterial: Made from Tygon R3603/R3607 or equivalent.Special Properties: Inexpensive all-around tubing for general laboratory applicationsChemical Compatibility: Excellent for aqueous solutions of the following acids and concentrations, up to 35% Nitric Acid, up to 37% Hydrochloric Acid, up to 25% Hydrofluoric Acid, up to 30% Hydrogen Peroxide.Limitations: Potential leaching of plasticizersGlass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Helix CT Locking Screw with Seal
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Helix CT Locking Screw and Seal. A replacement Helix Constant Torque Locking Screw and Seal. This is what secures the nebulizer in Glass Expansion spray chambers and creates the gas tight seal between the nebulizer and the spray chamber. To ensure a gas tight seal replace the seal every 6 months.Damage to the Helix CT insert of a TFE spray chamber can occur over time due to overtightening of the Helix CT locking screw. This will happen if the Helix CT seal is worn and you continue to tighten the locking screw, this results in the nebulizer being pushed further into the spray chamber and the locking screw going past the threads of the Helix insert. Essentially stretching the softer TFE material and slowly deforming the Helix CT insert. The same can occur if the Helix CT locking screw is tightened without the nebulizer in place.To only replace the Helix CT Seal, order NC2081825.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion DuraMist Nebulizer 0.4mL/min, Includes NFT-16-50 UniFit Connector with 0.50mm ID x 1.6mm OD x 700mm long tubing (1 piece), EL-1 EzyLok Connector Kit, and 70-803-0911 Ratchet EzyLok Connector.
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
DuraMist U-Series Nebulizer 0.4mL/min, includes UniFit Connector with 0.50mm ID x 1.6mm OD x 700mm long tubing (1 pc) & EzyLok Connector (1 pc).Optimum nebulizer gas flow rate is 1.0L/min & sample flow rate is 0.4mL/min. Recommended not to exceed optimum 0.4mL/min sample flow rate; however, lower gas & sample flow rates are OK. The backpressure should read ~40 psi at 1.0L/min gas flow rate. DuraMist is an economical inert nebulizer for high-precision analysis & the highest tolerance to TDS, up to 30%. Made from PEEK, tolerates up to 5% HF.Replacement parts include P/N 502702959, EL-1 & 501907289.Recommend nebulizer maintenance tools, Fluka RBS25 (P/N NC9000117) & Eluo Nebulizer Cleaning Tool (P/N 501907353). When nebulizer is not in use, best to store in the provided hard plastic case.Consider upgrading to our new Direct Connect (DC) DuraMist to take advantage of the cost-effective design improvements.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Viton Pump Tube 2tag, 127mm spacing, 2.29mm ID, Purple/Black (PKT 12)
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Viton Pump Tube 2tag, 127mm spacing, 2.29mm ID Purple/Black (PKT 12).Tag Colors: Purple/BlackID mm: 2.29Wall Thickness mm: 0.85OD mm 3.99Overall Length: 175mm (127mm spacing between tags)Number of Tubes Per Pack: 12Physical Properties: Fluoropolymer elastomerSpecial Properties: Special tubing for concentrated acids and corrosive solventsMaterial: Made from Fluran HC F-5500-A or equivalent.Limitations: Limited service lifeGlass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Perkin Elmer US LLC High-Sensitivity GemTip Plastic Body Nebulizer Complete Assembly for AAnalyst
A complete GemTip High-Sensitivity plastic body nebulizer featuring Kalrez o-rings and plastic needle with Sapphire tip. This nebulizer was designed to obtain optimum sensitivity, detection limits and precision with flame atomic absorption for both air-acetylene and nitrous oxide-acetylene flames. This assembly includes: Capillary Tubing, Qty. 1 (09908265) Fine Adjustment Nut, Qty. 1 (N0371492) Gland Nut, Qty. 1 (N0371505) PTFE Tubing, Qty. 1 (09985708) Capillary Assembly for High-Sensitivity GemTip Nebulizers, Qty. 1 (N0371522) O-Ring for Capillary Assembly, Qty. 1 (09926083) Impact Bead for High-Sensitivity GemTip Nebulizer, Qty. 1 (B0505086) O-Ring for Nebulizer Body, Qty. 1 (09902015) Body Assembly for High-Sensitivity Nebulizer, Qty. 1 (N0370399) Locking Nut, Qty. 1 (N0371493) Spring, Qty. 1 (09902473) Connector Nut, Qty. 1 (N0371485) Magnet Holder Assembly, Qty.1 (N1010215) This nebulizer is compatible with the PerkinElmer AAnalyst 200/400*, AAnalyst100/300/700/800, and Models
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Tracey TFE Spray Chamber with Helix CT, 50ml cyclonic, PTFE.Includes UFT-16-75 UniFit Connector (1 unit) and 70-803-1439 Helix CT locking screw with seal (1 unit)
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Tracey PTFE spray chamber, includes Helix CT locking screw & seal (1 pc) & UniFit with 1.6mm OD x 0.75mm ID x 700mm long tube (1 pc). Made from PTFE for HF resistance, 50mL volume. Compatible with Thermo ICP-OES Iris, Tracescan, Trace, Advantage, Intrepid, Iris Duo Axial, & Thermo 6000 Duo ICP-OES.The Tracey PTFE is a HF-resistant cyclonic design with a proprietary Stediflow surface treatment that significantly improves sensitivity & precision, in addition to enhancing washout efficiency compared to other inert spray chamber designs. The interior surface can be refurbished at a nominal cost, average lifespan of treatment is 12 months.The main feature of the Helix CT interface is the built-in, ratcheting torque control mechanism that allows for a consistent, zero dead volume & chemically inert nebulizer seal.Replacement parts include NC1943061, NC2081825 & V-044, suggested to replace every 6 months.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More