Protein Purification Reagents and Kits
- (2)
- (119)
- (25)
- (2)
- (3)
- (1)
- (1)
- (2)
- (18)
- (4)
- (18)
- (1)
- (1)
- (6)
- (12)
- (1)
- (15)
- (48)
- (4)
- (4)
- (44)
- (1)
- (1)
- (1)
- (3)
- (1)
- (2)
- (2)
- (1)
- (2)
- (10)
- (13)
- (2)
- (3)
- (4)
- (5)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (42)
- (2)
- (6)
- (1)
- (2)
- (1)
- (4)
- (3)
- (1)
- (1)
- (53)
- (13)
- (7)
- (2)
- (1)
- (4)
- (1)
- (1)
- (1)
- (1)
- (1)
- (6)
- (4)
- (7)
- (1)
- (9)
- (254)
- (13)
- (2)
- (1)
- (3)
- (3)
- (3)
- (32)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (34)
- (79)
- (2)
- (2)
- (1)
- (6)
- (5)
- (10)
- (4)
- (3)
- (37)
- (1)
- (3)
- (3)
- (8)
- (95)
- (125)
- (2)
- (1)
- (1)
- (6)
- (7)
- (43)
- (11)
- (4)
- (5)
- (7)
- (5)
- (6)
- (3)
- (6)
- (9)
- (35)
- (6)
- (3)
- (10)
- (80)
- (3)
- (11)
- (39)
- (13)
- (22)
- (6)
- (3)
- (4)
- (3)
- (36)
- (2)
- (1)
- (1)
- (5)
- (5)
- (2)
- (1)
- (1)
- (1)
- (4)
- (10)
Filtered Search Results
Thermo Scientific™ HisPur™ Ni-NTA Resin
Purify His-tagged recombinant fusion proteins using high-capacity nickel-NTA (nitrilotriacetic acid) metal-chelate beads, spin columns and plates.
| Stationary Phase | Divalent Nickel, Metal Chelate |
|---|---|
| Type | Resin |
| Target | His-Tagged Protein |
| Content And Storage | Store at 4°C |
| Format | Bottle |
| Description | HisPur Ni-NTA Resin |
| Form | Liquid Suspension |
| Column Type | Affinity, Agarose Resin |
| Capacity (Metric) | Up to 60 mg of 6xHis-Tagged Protein Binding per mL Resin |
| Product Line | HisPur |
Thermo Scientific™ NE-PER™ Nuclear and Cytoplasmic Extraction Reagents
Efficiently lyse cells and extract separate cytoplasmic and nuclear protein fractions in less than two hours with this subcellular fractionation kit.
| Buffer | Lysis Buffer |
|---|---|
| Shipping Condition | Ambient |
| Form | Liquid |
| Product Type | Nuclear and Cytoplasmic Extraction Reagent |
| Reagent Type | Cell Lysis Buffer, Detergent Solution, Subcellular Fractionation |
| Product Line | NE-PER |
Thermo Scientific™ Detergent Removal Spin Columns & Plates
Rapidly eliminate high concentrations of detergents with minimal sample loss with detergent removal resins. Thermo Scientific HiPPR (High Protein and Peptide Recovery) resin is recommended for protein concentrations up to 100 μg/mL, while Thermo Scientific Pierce resin is suitable for concentrations over 100 μg/mL.
| Stationary Phase | Proprietary Ligand |
|---|---|
| Column Type | Proprietary Resin, Affinity |
| Purification Target | Detergent Removal |
Thermo Scientific™ Pierce™ High-Capacity EDTA-Compatible Ni-IMAC Resin
Pierce High-Capacity EDTA-Compatible Ni-IMAC Resin is designed for the purification of over-expressed His-tagged proteins from cell culture media.
| Binding Property | Chelator Stable |
|---|
Thermo Scientific™ HisPur™ Cobalt Resin
Gently purify His-tagged recombinant fusion proteins using cobalt (Co2+) immobilized metal chelate affinity (IMAC) beads, spin columns and plates.
| Stationary Phase | Metal Chelate, Divalent Cobalt |
|---|---|
| Type | Resin |
| Target | His-Tagged Protein |
| Content And Storage | Store at 4°C |
| Format | Bottle |
| Protein Form | Recombinant |
| Form | Liquid Suspension |
| Column Type | Affinity, Agarose Resin |
| Product Line | HisPur |
Thermo Scientific™ HisPur™ Ni-NTA Superflow Agarose
Perform FPLC purification of poly-histidine-tagged proteins with this nitrilotriacetic acid (NTA) modified Superflow 6 support charged with divalent nickel (Ni+2).
| Stationary Phase | Divalent Nickel, Metal Chelate |
|---|---|
| Type | Agarose |
| Target | His-Tagged Protein |
| Content And Storage | Store at 4°C |
| Format | Bottle |
| Form | Liquid Suspension |
| Column Type | Affinity, Agarose Resin |
| Capacity (Metric) | 20 mg His-Tagged GFP Binding per mL Resin |
| Product Line | HisPur |
Cytiva HisTrap™ FF Columns: 5 x 5mL
Optimize purifications of histidine-tagged proteins directly from homogenized, unclarified cells HisTrap™ FF Columns: 5 x 5mL are prepacked with precharged Ni Sepharose™ 6 Fast Flow media.
Cytiva PD MiniTrap™ G-10 Sample Preparation Columns
Use for buffer exchange and cleanup of biological samples, for example peptides, small proteins, and oligosaccharides. Cytiva Life Sciences™ PD MiniTrap™ G-10 Sample Preparation Columns are prepacked, single-use gravity columns.
Cytiva HisTrap™ HP Prepacked Columns
Purify histidine-tagged proteins directly from homogenized, unclarified cells. Cytiva HisTrap™ HP Prepacked Columns are prepacked with Ni Sepharose™ High Performance and designed for simple, high-resolution purification of histidine-tagged proteins by immobilized metal ion affinity chromatography (IMAC).
| Flow Rate | 4 mL/min. (1 mL), 5 mL/min. (5 mL) |
|---|---|
| Type | Pre-packed Column |
| Content And Storage | 4°C to 30°C |
| Description | HisTrap HP are nickel-charged IMAC columns for high resolution his-tagged protein purification with high binding capacity for maximized recovery. |
| Max. Operating Pressure | 5 bar (0.5 MPa, 70 psi) |
| pH Range | 3 to 12 |
| Material | Polypropylene |
| Support Type | 6% Highly Cross-linked Agarose |
Cytiva HisTrap™ excel Prepacked Columns
For capture and purification of histidine-tagged proteins secreted into eukaryotic cell culture supernatants. Cytiva Lifescience™ HisTrap™ excel Prepacked Columns are designed for fast and convenient purifications.
| Type | Pre-packed Column |
|---|---|
| Content And Storage | 4°C to 30°C |
| Description | HisTrap excel columns are prepacked with Ni Sepharose excel affinity resins for capture and purification of histidine-tagged proteins secreted into eukaryotic cell culture supernatants by immobilized metal ion affinity chromatography (IMAC). |
| Max. Operating Pressure | 5 bar (0.5 MPa, 70 psi) |
| pH Range | 2 to 12 |
| Material | Polypropylene |
| Support Type | 6% Highly Cross-linked Agarose |
Cytiva™ Protein Select™ Resin
An affinity chromatography resin for purifying recombinant proteins using the self-cleaving Cytiva™ Protein Select™ tag.
Invitrogen™ Ni-NTA Agarose
Nickel-charged affinity resin that can be used to purify recombinant proteins containing a polyhistidine (6xHis) sequence
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
| Type | Agarose |
|---|---|
| Stationary Phase | Ni-NTA |
| Content And Storage | The Ni-NTA resin is pre-charged and able to bind up to 50 mg of recombinant protein per 1 ml of resin. It is provided as a 50% slurry in 30% ethanol. The resin will appear blue in color when charged with Ni2+ . Store at +4°C. Ni-NTA resin is guaranteed stable for 6 months when properly stored. |
| Form | Suspension |
| Column Type | Affinity Column |
Thermo Scientific™ HisPur™ Ni-NTA Spin Columns, 1 mL
Purify His-tagged recombinant fusion proteins using high-capacity nickel-NTA (nitrilotriacetic acid) metal-chelate beads, spin columns and plates.
Thermo Scientific™ Mem-PER™ Plus Membrane Protein Extraction Kit
Perform small-scale solubilization and enrichment of integral membrane proteins and membrane-associated proteins in a simple reagent-based procedure.
Thermo Scientific™ HisPur™ Ni-NTA Spin Purification Kit, 1 mL
Purify His-tagged recombinant fusion proteins using high-capacity nickel-NTA (nitrilotriacetic acid) metal-chelate beads, spin columns and plates.