Chromatography Media
- (1)
- (1)
- (4)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (3)
- (4)
- (1)
- (1)
- (2)
- (2)
- (1)
- (1)
- (2)
- (4)
- (3)
- (2)
- (2)
- (3)
- (2)
- (3)
- (2)
- (1)
- (2)
- (1)
- (1)
- (2)
- (1)
- (2)
- (2)
- (1)
- (2)
- (1)
- (2)
- (1)
- (1)
- (2)
- (1)
- (2)
- (1)
- (1)
- (1)
- (2)
- (2)
- (1)
- (1)
- (1)
- (2)
- (2)
- (1)
- (2)
- (3)
- (1)
- (1)
- (1)
- (2)
- (2)
- (2)
- (2)
- (2)
- (1)
- (1)
- (2)
- (2)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (2)
- (1)
- (1)
- (2)
- (1)
- (2)
- (1)
- (3)
- (2)
- (7)
- (1)
- (2)
- (1)
- (4)
- (22)
- (2)
- (8)
- (3)
- (6)
- (6)
- (6)
- (1)
- (2)
- (1)
- (2)
Filtered Search Results
Cytiva HiTrap™ Capto™ PlasmidSelect
For the purification of supercoiled DNA to high quality for gene therapy and DNA vaccine applications
| Matrix | Capto™ PlasmidSelect |
|---|---|
| Length (Metric) | 2.5 cm |
| Product Type | Chromatography Resin |
| For Use With (Application) | Purification of Supercoiled DNA From Research Scale to cGMP Production |
| Max. Pressure | 5 bar (0.5 MPa) |
Cytiva HiTrap™ AVB Sepharose™ Columns
Enables purification of adeno associated viruses (AAV) in one step, with high purity and excellent yields. Cytiva HiTrap™ AVB Sepharose™ Columns are pre-packed with affinity chromatography medium (resin) for simple operation with a syringe, pump or chromatographic system.
| Particle Size | 24 to 44 μm |
|---|---|
| Ligand Type | 14 kD recombinant protein |
| Flow Rate | <150 cm/hr |
| Matrix | Cross-linked agarose |
| Stability | Stable to all commonly used aqueous buffers |
| pH Range | 3 to 10 |
| Product Type | HiTrap AVB Sepharose HP Column |
| Binding Capacity | >10▿12 genecopies/mL Chromatography Mediμm |
| Material | Polypropylene |
| Storage Requirements | Store prepacked column at 4°C to 30°C in 20% Ethanol and Media at 4°C to 8°C in 20% Ethanol. |
| For Use With (Application) | One Step Purification of Adeno Associated Viruses |
| Height (Metric) Bed | 25 mm |
| Max. Pressure | 70 psi (5 bar) |
Cytiva TALON™ Superflow Medium
Offers different selectivity compared to nickel-charged media. Cytiva TALON™ Superflow Medium used for purification of histidine-tagged recombinant proteins by IMAC.
| Particle Size | 60 to 160 μm |
|---|---|
| Ligand Type | Talon Superflow Cobalt-IMAC |
| Matrix | 6% Cross-Linked Agarose |
| Storage Buffer | 20% Ethanol |
| pH Range | 3 to 12 |
| Product Type | Talon Superflow Media |
| Binding Capacity | Up to 20 mg Histidine-tagged Protein |
| Storage Requirements | 4°C to 8°C |
| For Use With (Application) | For PurifiCatIon of Histidine-Tagged Recombinant Pby Immobilized Metal Affinity Chromatography |
Cytiva Capto™ MMC ImpRes Multimodal BioProcess™ Chromatography Medium
For high-resolution polishing of monoclonal antibodies (MAbs) and other biomolecules
| Particle Size | 40 μm |
|---|---|
| Ligand Type | Multimodal Weak CatIon Exchanger |
| Matrix | High-flow Agarose |
| Stability | 1 M Acetic Acid, 1 M NaOH, 2 M NaCl, 5% 1-Propanol, 30% Isopropanol, 70% Ethanol |
| Storage Buffer | 20% Ethanol, 0.2 M Sodium Acetate |
| pH Range | 3 to 12 |
| Product Type | Capto MMC ImpRes Media |
| Binding Capacity | 60 to 90 mg Mab/mL |
| Anion Exchange Capacity | 25 to 39 μM/mL |
| Storage Requirements | 4°C to 30°C |
| For Use With (Application) | For High Resolution Polishing of Monoclonal Antibodies (MAbs) and Other Biomolecules |
| Max. Pressure | 300 kPa |
Cytiva Strep-Tactin™ XT Sepharose™ Chromatography Resin
Chromatography resin for purification of recombinant proteins tagged with a Strep-tag™ II and Twin-Strep-tag™.
| Particle Size | 34 μm |
|---|---|
| Ligand Type | Strep-Tactin XT |
| Density (Metric) | Approx. 5 mg/mL resin |
| Matrix | Rigid, cross-linked agarose, spherical |
| Stability | Stable in all commonly used aqueous buffers |
| pH Range | 6 to 10 pH |
| Binding Capacity | Approx. 10 mg protein with Strep-tag II or Twin-Strep-tag/mL of resin |
| Storage Requirements | 2 to 8°C in 20% ethanol |
| For Use With (Application) | Purification of recombinant proteins tagged with Strep-tag II and Twin-Strep-tag |
Cytiva SOURCE™ 30S Chromatography Media
Chemically stable cation exchanger for high resolution polishing purification of proteins, peptides and oligonucleotides
Cytiva Q Sepharose™ XL
Hydrophilic base matrix ensures low levels of non-specific binding leading to low levels of host cell-derived impurities in elution pool
Cytiva His SpinTrap™ TALON™
Single-use spin column for high purity purification of histidine-tagged proteins
Cytiva His MultiTrap™ TALON™
For high-throughput screening of histidine-tagged proteins from clarified cell lysates
Cytiva Capto™ SP ImpRes BioProcess Media
A strong cation exchange BioProcess medium for efficient and cost-effective protein purification.
Cytiva Butyl-S Sepharose™ 6 Fast Flow Chromatography Media
The least hydrophobic medium in the Sepharose Fast Flow hydrophobic interaction chromatography (HIC) range and is particularly useful during the initial stages of purification process
Cytiva Q Sepharose™ High Performance Chromatography Media
Designed for high intermediate and polishing steps in downstream processing
Cytiva Capto™ Q Chromatography Media
Designed for capture and intermediate purification of proteins from large feed volumes. Cytiva CaptoTM Q Chromatography Media is a strong anion exchange BioProcess medium, designed to meet the demands of modern large-scale manufacturers.