Thermo Scientific™ GuardGOLD™ Capillary Columns Available on GSA/VA Contract for Federal Government customers only.

Protect your analytical column from damage and contamination from nonvolatile materials.

Manufacturer: Thermo Scientific™ 260500253

 View more versions of this product

Catalog No. 26-050-0253

  Check Availability
Add to Cart

    Specifications

    For Use With GC
    Length (Metric) 2m
    Item Description 2m L; 0.53mm nominal ID
    Diameter (Metric) 0.53mm

    Protect your analytical column from damage and contamination from nonvolatile materials using the ThermoScientific™ GuardGOLD™ Capillary columns. Facilitates Superior Analytic Performance Protects against column contamination caused by nonvolatile materials, extending the column lifetime Focuses target analytes at the head of the analytical column, leading to better chromatographic peak shape Highly deactivated to provide superior inertness, essential for analysis of active compounds High maximum operating temperature of 360°C

    Ideal for High-Throughput, High-Resolution LC

    The UltiMate 3000 Rapid Separation Well Plate Autosampler is strongly recommended for high-pressure, high-resolution applications. Short injection cycle times make it ideal for high-throughput applications. It is available in both nonthermostatted (WPS-3000RS) and thermostatted (WPS-3000TRS) versions.

    Performance and Features

    • Injection volume precision typically <0.15% RSD for 5µL injections
    • High-precision drive mechanism to deliver superior injection linearity of r2 >0.9999 (5–90µL)
    • Wide injection volume range from 0.2 to 500µL using three syringe and loop combinations for maximum injection flexibility
    • Low gradient delay volume of 140µL (default) or 50µL (with 25µL sample loop)
    • Volumetric accuracy better than ±0.5% for 20µL injections allow easy method transfer from HPLC to UHPLC
    • Sample thermostatting to protect thermally-sensitive analytes (WPS-3000TRS)

  • Description & Specifications

Related Products


Product Content Feedback

We continue to work to improve your shopping experience and your feedback regarding this content is very important to us. Please use the form below to provide feedback related to the content on this product.

Product Title

By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.

Cancel Submit