Hamilton Company
Browse a range of Hamilton Company liquid handling, sample management, syringes, and other products to support your HPLC and other analytical testing needs.
Filtered Search Results
Hamilton™ Microliter™ and Gastight™ Syringes: Model 75 for Agilent 7673, 7683, 7693 and 6850 ALS GC
Designed to work with Agilent 7673, 7683, 7693 and 6850 Automatic Liquid Sampler (ALS) gas chromatography (GC) autosamplers
| Length (Metric) | 43 mm |
|---|---|
| For Use With (Equipment) | Agilent 7673, 7683, 6850 Automatic Liquid Sampler, Gas Chromatography Autosamplers |
| Product Type | Microliter Syringe |
| Volume (Metric) | 5 μL |
| Length (English) | 1.7 in. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger) |
| Length (English) Needle | 1.71 in. |
| Min. Temperature (Metric) | 10°C |
| Max. Pressure | 2000 psi |
Hamilton™ 1700 Series Gastight™ Syringes: N Termination
Gastight version of the original 700 series syringes, ideal for dispensing volumes from 1 up to 500μL
| Length (Metric) | 51 mm |
|---|---|
| Connection Type | Cemented |
| Length (English) | 2 in. |
| Length (English) Needle | 2 in. |
Hamilton™ Microliter 700 Cemented Autosampler Syringes, Model 1701 N
The 700 series syringe is the original hand-fitted Hamilton syringe. This series of syringes is ideal for dispensing volumes from 0.5 μL up to 500 μL. A variety of different terminations and needle options are available in this series.
Hamilton™ 701N Microliter Syringes
The 700 series syringe is the original hand-fitted Hamilton syringe. This series of syringes is ideal for dispensing volumes from 0.5 μL up to 500 μL. A variety of different terminations and needle options are available in this series.
| Needle Point Number | 2 |
|---|---|
| Diameter (English) Inner | 0.019 in. |
| Length (Metric) | 51 mm |
| Volume (Metric) | 10 μL |
| Length (English) | 2 in. |
| Diameter (Metric) Inner | 0.048 cm |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger) |
| Max. Temperature (Metric) | 50°C |
| Max. Pressure | 137.9 bar |
| Diameter (Metric) Inner Needle | 0.013 cm |
| For Use With (Equipment) | Agilent 7670, 7671, and 7672 Automatic Liquid Sampler, Gas Chromatography Autosamplers |
| Product Type | Microliter Autosampler Syringe |
| Diameter (Metric) Outer | 0.66 cm |
| Connection Type | Cemented |
| Max. Temperature (English) | 122°F |
| Diameter (English) Outer | 0.26 in. |
| Model | 701 N |
| Needle Point Style | Sharp, Bevel, Curved, Non-coring |
| Diameter (Metric) Outer Needle | 0.047 cm |
| Length (English) Needle | 2 in. |
| Min. Temperature (Metric) | 10°C |
| Needle Gauge | 26s G |
| Diameter (English) Outer Needle | 0.018 in. |
| Diameter (English) Inner Needle | 0.005 in. |
Hamilton™ 700 Microliter Syringes: N Termination
The 700 series syringe is the original hand-fitted Hamilton syringe. This series of syringes is ideal for dispensing volumes from 0.5 μL up to 500 μL. A variety of different terminations and needle options are available in this series.
| Product Type | Microliter Syringe |
|---|---|
| Length (English) Needle | 2 in. |
| For Use With (Application) | For dispensing low volumes to achieve the highest level of accuracy and precision possible |
| Autoclavable | Not Autoclavable |
Hamilton™ Microliter™ and Gastight™ Syringes: Model 701 for Agilent 7673, 7683, 7693 and 6850 ALS GC
Designed to work with Agilent 7673, 7683, 7693 and 6850 Automatic Liquid Sampler (ALS) gas chromatography (GC) autosamplers
| For Use With (Equipment) | Agilent 7673, 7683, 6850 Automatic Liquid Sampler, Gas Chromatography Autosamplers |
|---|---|
| Product Type | Microliter Syringe |
| Diameter (Metric) Outer | 6.6 mm |
| Diameter (English) Outer | 0.26 in. |
| Volume (Metric) | 10 μL |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger) |
| Length (English) Needle | 1.71 in. |
| Min. Temperature (Metric) | 10°C |
Hamilton™ 1000 Series Gastight™ Syringes: Fixed-Needle Syringes, LTN Termination, 22 Gauge, 2 in. Needle Length
Mid-volume GASTIGHT syringe ideal for dispensing volumes from 100 μL up to 100 mL. A variety of different terminations and needle options are available in this series.
| Diameter (Metric) Inner Needle | 0.41 mm |
|---|---|
| Product Type | Gastight Syringe |
| Connection Type | Luer Tip, Cemented |
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Diameter (Metric) Outer Needle | 0.72 mm |
| Material | Borosilicate Glass (Barrel),PTFE (Tip),Stainless Steel (Plunger) |
| Length (English) Needle | 2 in. |
| For Use With (Application) | Ideal for manual and automated HPLC injections, commonly used in syringe pumps and other liquid handling instruments |
| Needle Gauge | 22 G |
| Max. Pressure | 200 psi |
| Diameter (English) Outer Needle | 0.028 in. |
| Diameter (English) Inner Needle | 0.016 in. |
Hamilton™ Microliter™ and Gastight™ Syringes Model 1701N For Agilent 7673, 7683, 7693 and 6850 ALS GC
Designed to work with Agilent 7673, 7683, 7693 and 6850 Automatic Liquid Sampler (ALS) gas chromatography (GC) autosamplers
| Needle Point Number | AS |
|---|---|
| Diameter (English) Inner | 0.018 in. |
| Length (Metric) | 43 mm |
| Volume (Metric) | 10 μL |
| Length (English) | 1.7 in. |
| Diameter (Metric) Inner | 0.46 mm |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger) |
| Max. Pressure | 1000 psi |
| For Use With (Equipment) | Agilent 7673, 7683, 6850 Automatic Liquid Sampler, Gas Chromatography Autosamplers |
| Product Type | Gastight Syringe |
| Diameter (Metric) Outer | 6.6 mm |
| Diameter (English) Outer | 0.26 in. |
| Needle Point Style | Cone |
| Length (English) Needle | 1.71 in. |
| Min. Temperature (Metric) | 10°C |
Hamilton™ 1000 Series Gastight™ Syringes: Removable-Needle, RN Termination, 22 Gauge, 2 in. Needle Length
Mid-volume GASTIGHT syringe ideal for dispensing volumes from 100 μL up to 100 mL.
| Quantity | Ea. |
|---|---|
| Min. Temperature (English) | 50°F |
| Max. Temperature (Metric) | 115°C |
| For Use With (Application) | Ideal for manual and automated HPLC injections, commonly used in syringe pumps and other liquid handling instruments |
| Max. Pressure | 200 psi |
| Diameter (Metric) Inner Needle | 0.41 mm |
| Product Type | Gastight Syringe |
| Connection Type | Removable |
| Max. Temperature (English) | 239°F |
| Diameter (Metric) Outer Needle | 0.72 mm |
| Length (English) Needle | 2 in. |
| Autoclavable | Autoclavable |
| Needle Gauge | 22 G |
| Diameter (English) Outer Needle | 0.028 in. |
| Diameter (English) Inner Needle | 0.016 in. |
Hamilton™ Metal Hub Custom Needles (Luer Lock)
Metal hub (nickel plated brass) needles can be used with TLL syringes and LT or TLL connectors. Needles are 304 stainless steel (sst.). Custom needle lengths and point styles are available.
Hamilton™ 700 Microliter™ Syringes: RN Termination
The 700 series syringe is the original hand-fitted Hamilton syringe. This series of syringes is ideal for dispensing volumes from 0.5 μL up to 500 μL. A variety of different terminations and needle options are available in this series.
| Needle Point Number | 2 |
|---|---|
| Length (Metric) | 51 mm |
| Product Type | Microliter Syringe |
| Connection Type | Removable |
| Max. Temperature (English) | 239°F |
| Length (English) | 2 in. |
| Needle Point Style | Sharp, Bevel, Curved, Non-coring |
| Min. Temperature (English) | 50°F |
| Material | PTFE (Tip),Stainless Steel (Plunger) |
| Length (English) Needle | 2 in. |
| Max. Temperature (Metric) | 115°C |
| For Use With (Application) | For dispensing low volumes to achieve the highest level of accuracy and precision possible |
Hamilton™ PRP-1 Reversed Phase HPLC Columns, 5um Particle Size
Stable alternative to C8 or C18 Columns
| Pore Size | 100 Å |
|---|---|
| Stationary Phase | PSDVB (Polystyrene Divinylbenzene) |
| Temperature | 5°C to 85°C |
| Phase | Reversed Phase |
| For Use With | Organic Compounds, Pharmaceuticals, Steroids, Nucleic Acids, Vitamins, Herbicides |
| Column Type | Reversed Phase |
| Max. Pressure | 5000 psi (345 bar) |
| Column Format | Analytical Column |
| Particle Size | 5 μm |
| Type | Column |
| Packing Material | PSDVB (Polystyrene Divinylbenzene) |
| Mobile Phase Compatibility | pH 1 to 13, 0 to 100% aqueous, organic modifier |
| pH | 1 to 13 |
| Film Thickness | 5 μm |
| USP Type | L21 |
Hamilton™ PRP-3 Semiprep/Preparative Guard Column
Protect analytical, semi-prep and preparative HPLC columns by removing particulate contaminants and highly adsorptive compounds from samples. Hamilton guard columns are available in stainless steel.
Hamilton™ Luer Lock Metal Hub Needles, 10 gauge, Metal Hub NDL, 2 in., point style 5
Luer Lock is an industry standard tapered termination utilized by most syringe manufacturers including medical Hypodermic syringes. Luer Lock needles are common because their design is controlled by a series of universal standards which guarantees compatibility between manufacturers.
Hamilton™ 1700 and 1000 Series Gastight™ SampleLock™ Syringes, 22 Gauge
Hamilton SampleLock syringes allow you to collect, store, transport and analyze liquid or gaseous samples without the danger of evaporative loss or environmental contamination.
| Needle Point Number | 2 |
|---|---|
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| For Use With (Application) | To collect, store, transport and analyze liquid or gaseous samples without the danger of evaporative loss or environmental contamination |
| Diameter (Metric) Inner Needle | 0.41 mm |
| Product Type | General Purpose Syringe |
| Connection Type | Sample Lock, Removable |
| Needle Point Style | Sharp, Bevel, Curved, Non-coring |
| Diameter (Metric) Outer Needle | 0.72 mm |
| Length (English) Needle | 2 in. |
| Autoclavable | Not Autoclavable |
| Min. Temperature (Metric) | 10°C |
| Needle Gauge | 22 G |
| Diameter (English) Outer Needle | 0.02 in. |
| Diameter (English) Inner Needle | 0.01 in. |