The BioTek Synergy LX multi-mode reader automates many common microplate assays. NOTE: Fluorescence filter cubes are required for fluorescence measurements (sold separately). For Research Use Only. Not for use in diagnostic procedures.
Width (English) | 15 in. |
---|---|
Shaking | Linear, Orbital, Double Orbital |
Absorbance Range | 200 to 900 nm |
Light Source | Xenon Flash |
For Use With (Application) | Nucleic acid and protein quantification, ELISA, BCA, Bradford and cell viability |
Width (Metric) | 38.1 cm |
USB Connections | 2 |
Detector Type | Photodiode,PMT |
Reading Options | End Point,Kinetic,Area Scanning,Absorbance Spectral Scanning |
Filters | Monochromator Bandpass |
Accuracy | Wavelength: ±2 nm; Optical Density: <1% at 2.0 OD, <3% at 2.5 OD |
Voltage | 100/240 V |
Bandwidth | ≤5 nm |
Certifications/Compliance | CE and TUV marked. RoHS compliant. |
Weight (Metric) | 12.3 kg |
Warranty | 1 year |
Depth (English) | 15 in. |
Software Language Versions | English |
Sensitivity | Fluorescence Intensity: Fluorescein 2 pM; Luminesence: 10 amol ATP |
Product Type | Multi-mode Microplate Reader |
Linearity | <1% from 0 to 2.5 OD |
Depth (Metric) | 38.1 cm |
Measurement Speed | 24 sec. (96 wells), 76 sec. (384 wells) |
Frequency | 50/60 Hz |
Weight (English) | 27 lb. |
Power Consumption | 24 VDC power supply compatible with 100/240 VAC at 50/60 Hz, 60 W (max.) |
Resolution | 0.001 OD |
Agilent BioTek Synergy HTX Multi-Mode Microplate Reader, IVD
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More

Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
The BioTek Synergy HTX is a compact, economical multi-mode reader for 6- to 384-well microplates and Take3 microvolume plates. For In Vitro Diagnostic Use.
Width (English) | 16 in. |
---|---|
Shaking | Linear, Orbital |
Software Type | Gen5 Microplate Reader and Imager Software,Gen5 Secure for 21 CFR Part 11 compliance (option) |
Absorbance Range | 200 to 999 nm, 1 nm increments |
Light Source | Xenon Flash,Tungsten Halogen (Alpha Detection/Fluorescence Intensity) |
Width (Metric) | 40.6 cm |
USB Connections | 2 |
Detector Type | Photodiode,PMT |
Reading Options | End Point,Kinetic,Spectral Scanning,Well Area Scanning |
Accuracy | Absorbance: ±2 nm; <1% at 2.0 OD, <3% at 3.0 OD; Dispense: ±1 μL or 2% |
No. of Dispensers | 2 Syringe Pumps |
Voltage | 100/240 V |
Certifications/Compliance | CE and TUV marked. RoHS compliant. |
Weight (Metric) | 18 kg |
Height (English) | 10 in. |
Height (Metric) | 25.4 cm |
Depth (English) | 15 in. |
Incubator Temperature | 4-Zone Incubation to 50°C with Condensation Control (±0.2°C at 37°C) |
Dynamic Range | Absorbance: 0 to 4 OD; Fluorescence Intensity/Luminesence: >6 decades |
Product Type | Multi-Mode Microplate Reader |
Depth (Metric) | 38 cm |
Measurement Speed | 31 sec. (96 wells), 80 sec. (384 wells) |
Frequency | 50/60 Hz |
Weight (English) | 40 lb. |
Compatibility | BioStack and Third Party Automation Compatible |
Plate Type | 6- to 384-well Plates |
Agilent BioTek 405LS Microplate Washer
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More


Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
The BioTek 405 LS washer has a well earned reputation as an economical plate washer that offers excellent performance and reliability.
Height (Metric) | 25.4 cm |
---|---|
Depth (English) | 17 in. |
Width (English) | 14 in. |
Width (Metric) | 35.6 cm |
Flow Rate | High to Low Flow; Optimized rates for cell assays |
Type | Microplate Washer |
Bottles | Optional (4 or 10 L) |
Washing Speed | 96-wells: 300 μL/well, 3 cycles: <30 s; 384-wells: 100 μL/well, 3 cycles: <80 s; 384-wells: 400 μL/well, 1 cycle: <20 s |
Dispense Volume | 25 to 3000 μL/well |
Precision | <3% CV: 300 μL/well (96-well washing); <4% CV: 80 μL/well (384-well washing) |
Depth (Metric) | 43.2 cm |
Wash Cycles | 1 to 250 |
Voltage | 100/240 V |
Humidity | 10 to 85%, noncondensing |
Soak Time | Programmable in minutes and seconds, up to 60 min. |
Increments | 1 μL |
Frequency | 50/60 Hz |
Residual Volume | <2 μL/well (96- and 384-well plates), 96-tube manifold for 96 wells, 192-tube for 384 wells |
Weight (English) | With internal buffer switching - 36 lb.; Without - 30 lb. |
Certifications/Compliance | CE and TUV marked. RoHS compliant. |
Height (English) | 10 in. |
Weight (Metric) | With internal buffer switching - 16.5 kg; Without - 13.5 kg |
Plate Type | 96- and 384-well, Low Profile and Standard, Solid and Filter Bottom (Pore Sizes 0.45 to 1.2 μm) Plates |
Agilent BioTek Seahorse Normalization
Seahorse Normalization for use with Cytation 1 and Cytation 5.
Agilent BioTek Cytation 5 Cell Imaging Only Reader
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More


Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Cytation 5 combines automated microscopy and conventional microplate detection in a configurable, upgradable platform. For Research Use Only. Not for use in diagnostic procedures.
Height (Metric) | 44.5 cm |
---|---|
Depth (English) | 20.2 in. |
Width (English) | 16.4 in. |
Contrast Methods | Fluorescence, phase contrast, brightfield, high contrast brightfield, color brightfield and phase contrast |
Shaking | Linear, Orbital, Double Orbital |
Wattage | 250 W max. |
Objectives | 1.25x, 2.5x (2.25x eff), 2.5x (2.75x eff), 4x, 10x, 20x, 40x, 60x |
Width (Metric) | 41.6 cm |
Dynamic Range | Absorbance: 0 to 4 OD; Fluorescence Intensity: 7 decades; Luminesence: >6 decades |
Type | Cell Imaging Only Microplate Reader |
For Use With (Equipment) | BioStack and Third Party Automation Compatible; BioSpa 8 Automated Incubator Compatible |
Depth (Metric) | 51.4 cm |
Weight (English) | 80 lb. |
Certifications/Compliance | CE and TUV marked. RoHS compliant. |
Camera | Sony CMOS, 16-bit Gray Scale, Standard or WFOV |
Temperature Range (Metric) | 4-Zone incubation to 65°C with Condensation Control (±0.2°C at 37°C) |
CO2 Concentration Range | 0 to 20% |
Weight (Metric) | 36.3 kg |
Height (English) | 17.5 in. |
Plate Type | Monochromator: 6- to 384-well plates; Filters: 6-to 1536 well plates; Imaging: 6-to 1536 well plates |
Agilent BioTek Cytation 1 Cell Imaging Multi-Mode Reader
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More


Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
BioTek Cytation 1 cell imaging multi-mode reader combines fluorescence and high contrast brightfield imaging with conventional multi-mode detection. For Research Use Only. Not for use in diagnostic procedures.
Height (Metric) | 44.5 cm |
---|---|
Depth (English) | 20 in. |
Width (English) | 16.5 in. |
Shaking | Linear, Orbital, Double Orbital |
Light Source | Xenon Flash |
Width (Metric) | 41.9 cm |
Reading Options | Endpoint, kinetic, area scanning, plate mode inject/read process and well mode inject/read process |
Type | Cell Imaging Multi-Mode Microplate Reader |
Depth (Metric) | 50.8 cm |
Software | Gen5 Microplate Reader and Imager Software |
Certifications/Compliance | CE and TUV marked. RoHS compliant. |
Temperature Range (Metric) | Incubation to 45°C |
O2 Concentration Range | 0 to 19% |
CO2 Concentration Range | 0 to 20% |
Height (English) | 17.5 in. |
Resolution | 0.3 μm/pixel at 20X |
Plate Type | 6-well to 384-well plates |
Agilent BioTek Lionheart FX Automated Microscope
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More


Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Lionheart FX automated microscope is a compact system for a broad range of imaging workflows. For Research Use Only. Not for use in diagnostic procedures.
Agilent BioTek MultiFlo FX Multi-Mode Dispenser
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More


Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
MultiFlo FX is an automated multi-mode reagent dispenser for 6- to 1536-well microplates.
Height (Metric) | 20.3 cm |
---|---|
Speed | 96 wells, 5 μL cass, 10 μL/ well: 3 s, 96 wells, 5 μL cass, 20 μL/ well: 3.5 s, 384 wells, 5 μL cass, 5 μL/ well: 6.5 s, 384 wells, 10 μL cass, 10 μL/ well: 8 s, 384 wells, 1 μL cass, 1 μL/ well: 6 s, 1536 wells, 1 μL cass, 1 μL/ well: 21 s |
Electrical Requirements | 90 W max. |
Depth (English) | 11.8 in. |
Width (English) | 17.2 in. |
For Use With (Application) | Primary/secondary screening assays, compound storage, genomics and proteomics research, ELISA, cell based washing, fixing, staining, volume or concentration normalization |
Width (Metric) | 43.5 cm |
Accuracy | ±5% at 1 μL, ±2.0% at 5 μL, ±2.0% at 10 μL |
Precision | <5% CV at 1 μL, <2.5% CV at 5 μL, <2.0% CV at 10 μL |
For Use With (Equipment) | BioStack and third party automation compatible; BioSpa 8 Automated Incubator compatible |
Product Type | Microplate Dispenser |
Depth (Metric) | 29.2 cm |
Voltage | 100/240 V |
Weight (English) | 14.3 lb. |
Software | LHC2 Software; LHC2 Secure for 21 CFR Part 11 compliance (option); SiLA Compliant driver (option) |
Certifications/Compliance | CE and TUV marked. RoHS compliant. |
Interface | Color touch screen; Create, edit or run multiple protocols onboard |
Weight (Metric) | 6.5 kg |
Height (English) | 8 in. |
Plate Type | Dispensing (peri pump and syringe): 96-, 384- and 1536-well standard, deep and PCR plates; 6-. 12-, 24- and 48-well plates (dispense tip configurable); Washing: 96-. 384-well standard plates; 6-, 12-, 24-,and 48-well plates (with compatible manifold configuration) |
Agilent BioTek Epoch Microplate Spectrophotometer
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More


Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Epoch microplate spectrophotometer has monochromator-based optics, for a filter-free, wide wavelength range for UV-Vis absorbance measurements. For Research Use Only. Not for use in diagnostic procedures.
Height (Metric) | 19.6 cm |
---|---|
Cuvette Size | 0.5 mm |
Width (English) | 12 in. |
Absorbance Range | 200 to 999 nm, 1 nm increments |
Light Source | Xenon Flash Lamp |
Width (Metric) | 30.5 cm |
Accuracy | ±2 nm |
Precision | ±0.2 nm |
Product Type | Microplate Reader |
Voltage | 100/240 V |
Bandwidth | 5 nm |
Weight (English) | <15 lb. |
Certifications/Compliance | CE and TUV marked. RoHS compliant. |
Hertz | 50/60 Hz |
Wavelength Range | 200 to 999 nm |
Weight (Metric) | 6.8 kg |
Resolution | 0.0001 OD |
Height (English) | 7.7 in. |
Plate Type | 6 to 384-well Plates |
Agilent BioTek 405LS Microplate Washer, IVD
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More


Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
The BioTek 405 LS washer has a well earned reputation as an economical plate washer that offers excellent performance and reliability. For In Vitro Diagnostic Use.
Height (Metric) | 25.4 cm |
---|---|
Depth (English) | 17 in. |
Width (English) | 14 in. |
Width (Metric) | 35.6 cm |
Flow Rate | High to Low Flow; Optimized rates for cell assays |
Type | Microplate Washer |
Bottles | Optional (4 or 10 L) |
Washing Speed | 96-wells: 300 μL/well, 3 cycles: <30 s; 384-wells: 100 μL/well, 3 cycles: <80 s; 384-wells: 400 μL/well, 1 cycle: <20 s |
Dispense Volume | 25 to 3000 μL/well |
Precision | <3% CV: 300 μL/well (96-well washing); <4% CV: 80 μL/well (384-well washing) |
Depth (Metric) | 43.2 cm |
Wash Cycles | 1 to 250 |
Voltage | 100/240 V |
Humidity | 10 to 85%, noncondensing |
Soak Time | Programmable in minutes and seconds, up to 60 min. |
Increments | 1 μL |
Frequency | 50/60 Hz |
Weight (English) | With internal buffer switching - 36 lb.; Without - 30 lb. |
Certifications/Compliance | CE and TUV marked. RoHS compliant. |
Height (English) | 10 in. |
Weight (Metric) | With internal buffer switching - 16.5 kg; Without - 13.5 kg |
Plate Type | 96- and 384-well, Low Profile and Standard, Solid and Filter Bottom (Pore Sizes 0.45 to 1.2 μm) Plates |
Agilent BioTek Epoch 2 Microplate Spectrophotometer, IVD
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More

Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
The BioTek Epoch 2 microplate spectrophotometer delivers excellent performance for UV-Vis absorbance measurements. For In Vitro Diagnostic Use.
Detector Type | Photodiode |
---|---|
Accuracy | ±2 nm |
Measurement Speed | 96 wells: 8 sec., 384 wells: 14 sec. |
Certifications/Compliance | CE and TUV marked. RoHS compliant. |
For Use With (Application) | Nucleic acid and protein quantification to ELISA and microbial growth assays |
Light Source | Xenon Flash Lamp |
Hertz | 50/60 Hz |
Wavelength Range | 200 to 999 nm, 1 nm increments |
Height (English) | 22 in. |
Agilent BioTek ELx405 Select Microplate Washer, IVD
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More

Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
The BioTek ELx405 Select is the first deep well plate washer that aspirates and dispenses into 96- and 384-well deep well and standard height microplates. For In Vitro Diagnostic Use.
Height (Metric) | 25.4 cm |
---|---|
Depth (English) | 17 in. |
Fluid Delivery Type | One positive displacement pump |
Width (English) | 14 in. |
Temperature (English) Operating | 59°F to 86°F |
Width (Metric) | 35.6 cm |
Type | Microplate Washer |
Precision | ≤3% CV |
Depth (Metric) | 43.2 cm |
Wash Cycles | 1 to 10 |
Voltage | 100/240 V |
Humidity | 10 to 80%, noncondensing |
Soak Time | Programmable in minutes and seconds, up to 60 min. |
Amperage | <8 A |
Frequency | 50/60 Hz |
Residual Volume | ≤2 μL/well |
Weight (English) | 30 lb. |
Certifications/Compliance | CE and TUV marked. RoHS compliant. |
Temperature (Metric) Operating | 15°C to 30°C |
Height (English) | 10 in. |
Display | Backlit LCD |
Weight (Metric) | 13.5 kg |
Agilent BioTek Cytation 5 Multi-Mode Only Reader
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More


Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Cytation 5 combines automated microscopy and conventional microplate detection in a configurable, upgradable platform. For Research Use Only. Not for use in diagnostic procedures.
Height (Metric) | 44.5 cm |
---|---|
Depth (English) | 20.2 in. |
Width (English) | 16.4 in. |
Shaking | Linear, Orbital, Double Orbital |
Wattage | 250 W max. |
Absorbance Range | 230 to 999 nm, 1 nm increments |
Light Source | Xenon Flash; 100 mW 680 nm laser (Alpha Detection) |
Width (Metric) | 41.6 cm |
Dynamic Range | Absorbance: 0 to 4 OD; Fluorescence Intensity: 7 decades; Luminesence: >6 decades |
Reading Options | End point, kinetic, spectral scanning and well area scanning |
Accuracy | Monochromator: ±2 nm; Dispenser: ±1 μL or 2% |
Type | Multi-Mode Only Microplate Reader |
No. of Dispensers | 2 Syringe Pumps |
Dispense Volume | 5 to 1000 μL, 1 μL increments |
For Use With (Equipment) | BioStack and Third Party Automation Compatible; BioSpa 8 Automated Incubator Compatible |
Depth (Metric) | 51.4 cm |
Weight (English) | 80 lb. |
Software | Gen5 Microplate Reader and Imager Software included; Gen5 Image+ and Image Prime software available for full image analysis; Gen5 Secure for 21 CFR Part 11 compliance (option) |
Certifications/Compliance | CE and TUV marked. RoHS compliant. |
Temperature Range (Metric) | 4-Zone incubation to 65°C with Condensation Control (±0.2°C at 37°C) |
CO2 Concentration Range | 0 to 20% |
Weight (Metric) | 36.3 kg |
Height (English) | 17.5 in. |
Agilent BioTek Epoch 2 Microplate Spectrophotometer
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More


Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
The BioTek Epoch 2 microplate spectrophotometer delivers excellent performance for UV-Vis absorbance measurements. For Research Use Only. Not for use in diagnostic procedures.
Detector Type | Photodiode |
---|---|
Accuracy | ±2 nm |
Measurement Speed | 96 wells: 8 sec., 384 wells: 14 sec. |
Certifications/Compliance | CE and TUV marked. RoHS compliant. |
For Use With (Application) | Nucleic acid and protein quantification to ELISA and microbial growth assays |
Light Source | Xenon Flash Lamp |
Hertz | 50/60 Hz |
Wavelength Range | 200 to 999 nm, 1 nm increments |
Height (English) | 22 in. |
Agilent BioTek Epoch Microplate Spectrophotometer, IVD
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More

Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Epoch microplate spectrophotometer has monochromator-based optics, for a filter-free, wide wavelength range for UV-Vis absorbance measurements. For In Vitro Diagnostic Use.
Height (Metric) | 19.6 cm |
---|---|
Cuvette Size | 0.5 mm |
Width (English) | 12 in. |
Software Type | Gen5 Data Analysis Software |
Absorbance Range | 200 to 999 nm, 1 nm increments |
Light Source | Xenon Flash Lamp |
Width (Metric) | 30.5 cm |
Accuracy | ±2 nm |
Precision | ±0.2 nm |
Product Type | Microplate Reader |
Voltage | 100/240 V |
Bandwidth | 5 nm |
Weight (English) | <15 lb. |
Certifications/Compliance | CE and TUV marked. RoHS compliant. |
Hertz | 50/60 Hz |
Wavelength Range | 200 to 999 nm |
Weight (Metric) | 6.8 kg |
Resolution | 0.0001 OD |
Height (English) | 7.7 in. |
Plate Type | 6 to 384-well Plates |