Hamilton™ Microliter 700 Cemented Autosampler Syringes, Model 1701 N
The 700 series syringe is the original hand-fitted Hamilton syringe. This series of syringes is ideal for dispensing volumes from 0.5 μL up to 500 μL. A variety of different terminations and needle options are available in this series.

Hamilton™ Microliter™ and Gastight™ Syringes: Model 701 for Agilent 7673, 7683, 7693 and 6850 ALS GC
Designed to work with Agilent 7673, 7683, 7693 and 6850 Automatic Liquid Sampler (ALS) gas chromatography (GC) autosamplers

For Use With (Equipment) | Agilent 7673, 7683, 6850 Automatic Liquid Sampler, Gas Chromatography Autosamplers |
---|---|
Product Type | Microliter Syringe |
Diameter (Metric) Outer | 6.6 mm |
Diameter (English) Outer | 0.26 in. |
Volume (Metric) | 10 μL |
Min. Temperature (English) | 50°F |
Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger) |
Length (English) Needle | 1.71 in. |
Min. Temperature (Metric) | 10°C |
Hamilton™ Kel-F Hub Sharp Non-Coring Needles (Luer Lock)
Kel-F hub (KF) needles can be used with Luer Tip (LT) and PTFE Luer Lock (TLL) syringes and connectors. Standard needle length is 2 in. (51 mm). Custom lengths and point styles are available.

For Use With (Equipment) | Luer-tip and PTFE Luer-lock Syringes and Connectors |
---|---|
Product Type | Kel-F Hub Needle |
Material | Stainless Steel |
Length (English) Needle | 2 in. |
Autoclavable | Not Autoclavable |
Hamilton™ Modified 7000 Microliter™ Syringes
This series of syringes is ideal for dispensing volumes from 0.05 μL up to 5 μL. The 7000 series is the only zero dead volume syringe. The fine gauge plunger wire travels to the tip of the needle ensuring that all solvent is expelled from the needle.

Product Type | General Purpose Syringe |
---|---|
Diameter (Metric) Outer | 7.82 mm |
Connection Type | Knurled Hub, Removable |
Max. Temperature (English) | 239°F |
Diameter (English) Outer | 0.3 in. |
Quantity | Ea. |
Min. Temperature (English) | 50°F |
Length (English) Needle | 2.75 in. |
Max. Temperature (Metric) | 115°C |
Autoclavable | Autoclavable |
Min. Temperature (Metric) | 10°C |
Diameter (English) Outer Needle | 0.02 in. |
Hamilton™ Microliter™ and Gastight™ Syringes Model 1701N For Agilent 7673, 7683, 7693 and 6850 ALS GC
Designed to work with Agilent 7673, 7683, 7693 and 6850 Automatic Liquid Sampler (ALS) gas chromatography (GC) autosamplers

Needle Point Number | AS |
---|---|
Diameter (English) Inner | 0.018 in. |
Length (Metric) | 43 mm |
Volume (Metric) | 10 μL |
Length (English) | 1.7 in. |
Diameter (Metric) Inner | 0.46 mm |
Min. Temperature (English) | 50°F |
Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger) |
Max. Pressure | 1000 psi |
For Use With (Equipment) | Agilent 7673, 7683, 6850 Automatic Liquid Sampler, Gas Chromatography Autosamplers |
Product Type | Gastight Syringe |
Diameter (Metric) Outer | 6.6 mm |
Diameter (English) Outer | 0.26 in. |
Needle Point Style | Cone |
Length (English) Needle | 1.71 in. |
Min. Temperature (Metric) | 10°C |
Hamilton™ 1000 Series Gastight™ Syringes: Luer Lock Syringes, TLL Termination
Mid-volume GASTIGHT syringe ideal for dispensing volumes from 100 μL up to 100 mL.

Needle Point Number | No Needle Included |
---|---|
Product Type | Gastight Syringe |
Quantity | Ea. |
For Use With (Application) | Ideal for manual and automated HPLC injections, commonly used in syringe pumps and other liquid handling instruments |
Hamilton™ 1700 Series Gastight™ Syringes: N Termination
Gastight version of the original 700 series syringes, ideal for dispensing volumes from 1 up to 500μL

Length (Metric) | 51 mm |
---|---|
Connection Type | Cemented |
Length (English) | 2 in. |
Length (English) Needle | 2 in. |
Length (Metric) | 17.78 cm |
---|---|
Product Type | Cleaning Wire |
Length (English) | 7 in. |
Material | Tungsten |
Hamilton™ Metal Hub Sharp Non-Coring Needles (Luer Lock)
Metal hub (nickel plated brass) needles can be used with TLL syringes and LT or TLL connectors. Needles are 304 stainless steel (sst.). Standard needle length is 2 in. (51mm). Custom needle lengths and point styles are available.

Product Type | Replacement Needle |
---|---|
Needle Point Style | Sharp, Bevel, Curved |
Length (English) Needle | 2 in. |
Hamilton™ 1700 Series Gastight™ Syringes: LTN Termination
Gastight version of the original 700 series syringes, ideal for dispensing volumes from 1 up to 500μL

Diameter (English) Inner | 0.12 in. |
---|---|
Length (Metric) | 51 mm |
Volume (Metric) | 500 μL |
Length (English) | 2 in. |
Diameter (Metric) Inner | 3.26 mm |
Quantity | Ea. |
Min. Temperature (English) | 50°F |
Material | Borosilicate Glass (Barrel),PTFE (Tip),Stainless Steel (Plunger) |
Max. Temperature (Metric) | 50°C |
For Use With (Application) | Ideal for dispensing both liquids and gases, useful for samples with dissolved or suspended molecules |
Max. Pressure | 700 psi |
Diameter (Metric) Inner Needle | 0.41 mm |
Product Type | Gastight Syringe |
Diameter (Metric) Outer | 7.75 mm |
Connection Type | Luer Tip, Cemented |
Max. Temperature (English) | 122°F |
Diameter (English) Outer | 0.3 in. |
Model | 1750 |
Diameter (Metric) Outer Needle | 0.72 mm |
Length (English) Needle | 2 in. |
Autoclavable | Not Autoclavable |
Min. Temperature (Metric) | 10°C |
Needle Gauge | 22 G |
Diameter (English) Outer Needle | 0.02 in. |
Diameter (English) Inner Needle | 0.01 in. |
Hamilton™ Microliter™ and Gastight™ Syringes: Model 75 for Agilent 7673, 7683, 7693 and 6850 ALS GC
Designed to work with Agilent 7673, 7683, 7693 and 6850 Automatic Liquid Sampler (ALS) gas chromatography (GC) autosamplers

Length (Metric) | 43 mm |
---|---|
For Use With (Equipment) | Agilent 7673, 7683, 6850 Automatic Liquid Sampler, Gas Chromatography Autosamplers |
Product Type | Microliter Syringe |
Volume (Metric) | 5 μL |
Length (English) | 1.7 in. |
Min. Temperature (English) | 50°F |
Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger) |
Length (English) Needle | 1.71 in. |
Min. Temperature (Metric) | 10°C |
Max. Pressure | 2000 psi |
Hamilton™ 701N Microliter Syringes
The 700 series syringe is the original hand-fitted Hamilton syringe. This series of syringes is ideal for dispensing volumes from 0.5 μL up to 500 μL. A variety of different terminations and needle options are available in this series.

Needle Point Number | 2 |
---|---|
Diameter (English) Inner | 0.019 in. |
Length (Metric) | 51 mm |
Volume (Metric) | 10 μL |
Length (English) | 2 in. |
Diameter (Metric) Inner | 0.048 cm |
Min. Temperature (English) | 50°F |
Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger) |
Max. Temperature (Metric) | 50°C |
Max. Pressure | 137.9 bar |
Diameter (Metric) Inner Needle | 0.013 cm |
For Use With (Equipment) | Agilent 7670, 7671, and 7672 Automatic Liquid Sampler, Gas Chromatography Autosamplers |
Product Type | Microliter Autosampler Syringe |
Diameter (Metric) Outer | 0.66 cm |
Connection Type | Cemented |
Max. Temperature (English) | 122°F |
Diameter (English) Outer | 0.26 in. |
Model | 701 N |
Needle Point Style | Sharp, Bevel, Curved, Non-coring |
Diameter (Metric) Outer Needle | 0.047 cm |
Length (English) Needle | 2 in. |
Min. Temperature (Metric) | 10°C |
Needle Gauge | 26s G |
Diameter (English) Outer Needle | 0.018 in. |
Diameter (English) Inner Needle | 0.005 in. |
Hamilton™ 1000 Series Gastight™ Syringes: Fixed-Needle Syringes, LTN Termination, 22 Gauge, 2 in. Needle Length
Mid-volume GASTIGHT syringe ideal for dispensing volumes from 100 μL up to 100 mL. A variety of different terminations and needle options are available in this series.

Diameter (Metric) Inner Needle | 0.41 mm |
---|---|
Product Type | Gastight Syringe |
Connection Type | Luer Tip, Cemented |
Quantity | Ea. |
Min. Temperature (English) | 50°F |
Diameter (Metric) Outer Needle | 0.72 mm |
Material | Borosilicate Glass (Barrel),PTFE (Tip),Stainless Steel (Plunger) |
Length (English) Needle | 2 in. |
For Use With (Application) | Ideal for manual and automated HPLC injections, commonly used in syringe pumps and other liquid handling instruments |
Needle Gauge | 22 G |
Max. Pressure | 200 psi |
Diameter (English) Outer Needle | 0.028 in. |
Diameter (English) Inner Needle | 0.016 in. |
Hamilton™ Microliter™ and Gastight™Model 7001 GC Syringes: For Agilent 7673, 7683, 7693 and 6850 ALS
Designed to work with Agilent 7673, 7683, 7693 and 6850 Automatic Liquid Sampler (ALS) gas chromatography (GC) autosamplers
Needle Point Number | AS |
---|---|
Diameter (English) Inner | 0.049 in. |
Length (Metric) | 43 mm |
Volume (Metric) | 1 μL |
Length (English) | 1.7 in. |
Diameter (Metric) Inner | 1.24 mm |
Quantity | Ea. |
Min. Temperature (English) | 50°F |
Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger) |
Max. Temperature (Metric) | 155°C |
Max. Pressure | 6000 psi |
For Use With (Equipment) | Agilent 7673, 7683, 6850 Automatic Liquid Sampler, Gas Chromatography Autosamplers |
Product Type | Microliter Syringe |
Diameter (Metric) Outer | 6.6 mm |
Connection Type | Removable |
Max. Temperature (English) | 239°F |
Diameter (English) Outer | 0.26 in. |
Model | 7001 |
Needle Point Style | Cone |
Length (English) Needle | 1.71 in. |
Min. Temperature (Metric) | 10°C |
Hamilton™ Gastight™ Waters WISP Autosampler Syringes
Designed for use with Waters WISP HPLC autosamplers
For Use With (Equipment) | Waters WISP HPLC Autosamplers |
---|---|
Product Type | Gastight Syringe |
Diameter (Metric) Outer | 7.75 mm |
Max. Temperature (English) | 239°F |
Diameter (English) Outer | 0.305 in. |
Quantity | Ea. |
Min. Temperature (English) | 50°F |
Max. Temperature (Metric) | 115°C |
Autoclavable | Autoclavable |
Min. Temperature (Metric) | 10°C |