Manual Gas Tight Syringes
Gas tight syringes for manual injections on GC instruments; includes fixed-needle, removable-needle formats in various sizes, needle gauges, needle point styles, and terminations; includes zero dead-volume and headspace syringes.
- (16)
- (10)
- (30)
- (7)
- (85)
- (21)
- (25)
- (1)
- (60)
- (6)
- (1)
- (2)
- (9)
- (1)
- (1)
- (2)
- (23)
- (1)
- (2)
- (42)
- (1)
- (8)
- (57)
- (42)
- (23)
- (5)
- (57)
- (7)
- (45)
- (3)
- (4)
- (5)
- (1)
- (3)
- (102)
- (16)
- (110)
- (1)
- (44)
- (12)
- (2)
- (2)
- (16)
- (7)
- (7)
- (36)
- (15)
- (38)
- (57)
- (1)
- (2)
- (13)
- (11)
- (1)
- (90)
- (10)
- (56)
- (23)
- (12)
- (14)
- (48)
- (10)
- (1)
- (3)
- (10)
- (23)
- (1)
- (1)
- (132)
- (11)
- (1)
- (4)
- (4)
- (208)
- (1)
- (8)
- (1)
- (8)
- (7)
- (297)
- (13)
- (10)
- (15)
- (6)
- (183)
- (1)
- (2)
- (14)
- (1)
- (2)
- (1)
- (2)
- (1)
- (4)
- (2)
- (24)
- (4)
- (12)
- (9)
- (2)
- (12)
- (11)
- (3)
- (9)
- (5)
- (2)
- (6)
- (2)
- (25)
- (1)
- (3)
- (17)
- (2)
- (1)
- (1)
- (2)
- (1)
- (8)
- (1)
- (7)
- (5)
Filtered Search Results
Hamilton™ 701N Microliter Syringes
The 700 series syringe is the original hand-fitted Hamilton syringe. This series of syringes is ideal for dispensing volumes from 0.5 μL up to 500 μL. A variety of different terminations and needle options are available in this series.
| Needle Point Number | 2 |
|---|---|
| Diameter (English) Inner | 0.019 in. |
| Length (Metric) | 51 mm |
| Volume (Metric) | 10 μL |
| Length (English) | 2 in. |
| Diameter (Metric) Inner | 0.048 cm |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger) |
| Max. Temperature (Metric) | 50°C |
| Max. Pressure | 137.9 bar |
| Diameter (Metric) Inner Needle | 0.013 cm |
| For Use With (Equipment) | Agilent 7670, 7671, and 7672 Automatic Liquid Sampler, Gas Chromatography Autosamplers |
| Product Type | Microliter Autosampler Syringe |
| Diameter (Metric) Outer | 0.66 cm |
| Connection Type | Cemented |
| Max. Temperature (English) | 122°F |
| Diameter (English) Outer | 0.26 in. |
| Model | 701 N |
| Needle Point Style | Sharp, Bevel, Curved, Non-coring |
| Diameter (Metric) Outer Needle | 0.047 cm |
| Length (English) Needle | 2 in. |
| Min. Temperature (Metric) | 10°C |
| Needle Gauge | 26s G |
| Diameter (English) Outer Needle | 0.018 in. |
| Diameter (English) Inner Needle | 0.005 in. |
Hamilton™ 800 Microliter™ Syringes, RN Termination
Attached to the flange of the 700 series syringe is a blue Syringe Holder that provides a spot to hold the syringe that will not heat up the barrel causing dispense inaccuracies. Additionally it provides support to small volume plungers that are prone to bending during injection. This series of syringes is ideal for dispensing volumes from 0.5 μL up to 250 μL.
| Needle Point Number | 2 |
|---|---|
| Length (Metric) | 51 mm |
| Connection Type | Removable |
| Length (English) | 2 in. |
| Needle Point Style | Sharp, Bevel, Curved, Non-coring |
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger) |
| Length (English) Needle | 2 in. |
| For Use With (Application) | Ideal for dispensing liquid to achieve the highest level of accuracy and precision possible, recommended for septum penetration |
| Autoclavable | Autoclavable |
| Min. Temperature (Metric) | 10°C |
| Max. Pressure | 2000 psi |
Hamilton™ 1700/1000 Series Gastight™ Instrument Syringes: C Termination
Syringes are designed to fit into, or with, various different instruments such as the MICROLAB™ 500 and MICROLAB 1000
| Needle Point Number | No Needle Included |
|---|---|
| Product Type | Gastight Syringe |
| Connection Type | ChemSeal |
| Max. Temperature (English) | 239°F |
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),PTFE (Tip) |
| Max. Temperature (Metric) | 115°C |
| For Use With (Application) | For dispensing volumes from 100μL up to 100mL |
| Autoclavable | Autoclavable |
Hamilton™ 1700 Series Gastight™ Syringes: RN Termination
Gastight version of the original 700 series syringes, ideal for dispensing volumes from 1 up to 500μL
| Length (Metric) | 51 mm |
|---|---|
| Product Type | Gastight Syringe |
| Connection Type | Removable |
| Max. Temperature (English) | 239°F |
| Length (English) | 2 in. |
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),PTFE (Tip),Stainless Steel (Plunger) |
| Length (English) Needle | 2 in. |
| Max. Temperature (Metric) | 115°C |
| For Use With (Application) | Ideal for dispensing both liquids and gases, useful for samples with dissolved or suspended molecules |
| Autoclavable | Autoclavable |
| Min. Temperature (Metric) | 10°C |
Hamilton™ 1800 Series Gastight™ Removable-Needle Syringes
Reinforced plunger version of the 1700 series syringes is ideal for dispensing volumes from 1 μL up to 500 μL.
| Needle Point Number | 2 |
|---|---|
| Connection Type | Removable |
| Max. Temperature (English) | 239°F |
| Needle Point Style | Sharp, Bevel, Curved, Non-coring |
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),PTFE (Tip),Stainless Steel (Plunger) |
| Length (English) Needle | 2 in. |
| Max. Temperature (Metric) | 115°C |
| For Use With (Application) | Dispensing volumes from 1μL up to 500μL |
| Autoclavable | Autoclavable |
| Min. Temperature (Metric) | 10°C |
| Diameter (English) Inner Needle | 0.005 in. |
Hamilton™ Microliter 700 Cemented Autosampler Syringes, Model 75 N
The 700 series syringe is the original hand-fitted Hamilton syringe. This series of syringes is ideal for dispensing volumes from 0.5 μL up to 500 μL. A variety of different terminations and needle options are available in this series.
Hamilton™ 1700/1000 Series Gastight™ Instrument Syringes: TLLX Termination
Syringes are designed to fit into, or with, various different instruments such as the MICROLAB™ 500 and MICROLAB 1000
| Includes | Instrument plunger stop |
|---|---|
| Needle Point Number | No Needle Included |
| For Use With (Equipment) | Microlab 500 Instruments |
| Product Type | Gastight Syringe |
| Connection Type | Luer Lock |
| Max. Temperature (English) | 239°F |
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),PTFE (Tip) |
| Max. Temperature (Metric) | 115°C |
Thermo Scientific™ Removable-Needle Autosampler Syringes for GC Instruments
Thermo Scientific™ Removable-Needle Autosampler Syringes for GC Instruments are accurate and reproducible over a range of volumes.
Hamilton™ 700 7000/1700 1000 Series Microliter™/Gastight™: KH Termination
Syringes have built-in Chaney Adapters
| Needle Point Number | 3 |
|---|---|
| Length (Metric) | 70 mm |
| Length (English) | 2.75 in. |
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger) |
| Max. Temperature (Metric) | 115°C |
| For Use With (Application) | Designed for liquid sampling to achieve the highest level of accuracy and precision possible, for use with HPLC injection valves and for sample pipetting |
| Max. Pressure | 6000 psi |
| Product Type | Microliter Syringe |
| Connection Type | Knurled Hub |
| Max. Temperature (English) | 239°F |
| Needle Point Style | Blunt |
| Length (English) Needle | 2.75 in. |
| Autoclavable | Autoclavable |
| Min. Temperature (Metric) | 10°C |
Thermo Scientific™ TriPlus RSH Autosampler Fixed GT Needle Syringe
Thermo Scientific™ TriPlus RSH Autosampler Fixed GT Needle Syringes are accurate and reproducible over a range of volumes.
| Connection Type | Fixed |
|---|---|
| Material | Stainless Steel (Needle),Stainless Steel (Plunger) |
| Length (Metric) Needle | 57 mm |
Thermo Scientific™ GC Syringe for CTC
Thermo Scientific™ Gastight GC Syringes are accurate and reproducible over a range of volumes.
Synthware™ Cannula
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Cannula for the transfer and handling of air sensitive materials.
| Color | Silver |
|---|---|
| Graduated | No |
| Quantity | 1 Ea. |
| Material | Stainless Steel |
| For Use With (Application) | Organic Synthesis |
| Sterility | Non-sterile |
| Connection Type | Fixed |
|---|
Hamilton™ 700 7000/1700 1000 Series Microliter™/Gastight™: TLL Termination
Syringes have built-in Chaney Adapters
| Needle Point Number | No Needle Included |
|---|
Hamilton™ 700 Series Cemented Needle Syringes
This series of syringes is ideal for dispensing volumes from 0.5 up to 500μL.
| Connection Type | Cemented |
|---|---|
| Material | Borosilicate Glass,Stainless Steel |