Manual Gas Tight Syringes
Gas tight syringes for manual injections on GC instruments; includes fixed-needle, removable-needle formats in various sizes, needle gauges, needle point styles, and terminations; includes zero dead-volume and headspace syringes.
- (16)
- (10)
- (30)
- (7)
- (87)
- (21)
- (25)
- (1)
- (60)
- (6)
- (1)
- (2)
- (9)
- (1)
- (1)
- (2)
- (23)
- (1)
- (2)
- (42)
- (1)
- (8)
- (57)
- (41)
- (23)
- (5)
- (57)
- (7)
- (45)
- (3)
- (4)
- (5)
- (1)
- (3)
- (102)
- (16)
- (110)
- (1)
- (45)
- (12)
- (2)
- (2)
- (16)
- (7)
- (7)
- (36)
- (15)
- (39)
- (56)
- (1)
- (2)
- (13)
- (11)
- (1)
- (89)
- (10)
- (58)
- (23)
- (12)
- (14)
- (48)
- (10)
- (1)
- (3)
- (10)
- (23)
- (1)
- (1)
- (132)
- (11)
- (1)
- (4)
- (4)
- (207)
- (1)
- (8)
- (1)
- (8)
- (7)
- (297)
- (13)
- (10)
- (15)
- (6)
- (182)
- (1)
- (2)
- (14)
- (1)
- (2)
- (1)
- (2)
- (1)
- (4)
- (2)
- (24)
- (4)
- (12)
- (9)
- (2)
- (2)
- (12)
- (11)
- (3)
- (9)
- (5)
- (2)
- (6)
- (2)
- (25)
- (1)
- (3)
- (17)
- (2)
- (1)
- (1)
- (2)
- (1)
- (8)
- (1)
- (7)
- (5)
Filtered Search Results
Hamilton™ Super Syringe Gastight™ Syringes
Large volume GASTIGHT syringe ideal for dispensing volumes from 50mL up to 2L. The Super Syringe is the only Hamilton syringe that is made with an acrylic barrel instead of a glass barrel.
| Product Type | General Purpose Syringe |
|---|---|
| Material | Acrylic (Barrel) |
| For Use With (Application) | For air sampling, preparing gas standards, calibrating reservoirs, pneumographs and spirometers |
Hamilton™ 701N Microliter Syringes
The 700 series syringe is the original hand-fitted Hamilton syringe. This series of syringes is ideal for dispensing volumes from 0.5 μL up to 500 μL. A variety of different terminations and needle options are available in this series.
| Needle Point Number | 2 |
|---|---|
| Diameter (English) Inner | 0.019 in. |
| Length (Metric) | 51 mm |
| Volume (Metric) | 10 μL |
| Length (English) | 2 in. |
| Diameter (Metric) Inner | 0.048 cm |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger) |
| Max. Temperature (Metric) | 50°C |
| Max. Pressure | 137.9 bar |
| Diameter (Metric) Inner Needle | 0.013 cm |
| For Use With (Equipment) | Agilent 7670, 7671, and 7672 Automatic Liquid Sampler, Gas Chromatography Autosamplers |
| Product Type | Microliter Autosampler Syringe |
| Diameter (Metric) Outer | 0.66 cm |
| Connection Type | Cemented |
| Max. Temperature (English) | 122°F |
| Diameter (English) Outer | 0.26 in. |
| Model | 701 N |
| Needle Point Style | Sharp, Bevel, Curved, Non-coring |
| Diameter (Metric) Outer Needle | 0.047 cm |
| Length (English) Needle | 2 in. |
| Min. Temperature (Metric) | 10°C |
| Needle Gauge | 26s G |
| Diameter (English) Outer Needle | 0.018 in. |
| Diameter (English) Inner Needle | 0.005 in. |
| Connection Type | Fixed |
|---|
Hamilton™ 1700/1000 Series Gastight™ Instrument Syringes: TLLX Termination
Syringes are designed to fit into, or with, various different instruments such as the MICROLAB™ 500 and MICROLAB 1000
| Includes | Instrument plunger stop |
|---|---|
| Needle Point Number | No Needle Included |
| For Use With (Equipment) | Microlab 500 Instruments |
| Product Type | Gastight Syringe |
| Connection Type | Luer Lock |
| Max. Temperature (English) | 239°F |
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),PTFE (Tip) |
| Max. Temperature (Metric) | 115°C |
Hamilton™ 1000 Series Gastight™ Syringes: Luer Lock Syringes, TLL Termination (No Flange)
Mid-volume GASTIGHT syringe ideal for dispensing volumes from 100 μL up to 100 mL.
Hamilton™ 1700/1000 Series Gastight™ Instrument Syringes: AD Termination
Syringes are designed to fit into, or with, various different instruments such as the MICROLAB™ 500 and MICROLAB 1000
| Needle Point Number | No Needle Included |
|---|---|
| For Use With (Equipment) | Microlab 1000 Diluters/Dispensers |
| Product Type | Gastight Syringe |
| Max. Temperature (English) | 122°F |
| Quantity | Ea. |
| Min. Temperature (English) | 68°F |
| Material | Borosilicate Glass (Barrel),PTFE (Tip) |
| Max. Temperature (Metric) | 50°C |
| Product Line | AccuDil |
Thermo Scientific™ Removable-Needle Autosampler Syringes for GC Instruments
Thermo Scientific™ Removable-Needle Autosampler Syringes for GC Instruments are accurate and reproducible over a range of volumes.
Hamilton™ 700 7000/1700 1000 Series Microliter™/Gastight™: KH Termination
Syringes have built-in Chaney Adapters
| Needle Point Number | 3 |
|---|---|
| Length (Metric) | 70 mm |
| Length (English) | 2.75 in. |
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger) |
| Max. Temperature (Metric) | 115°C |
| For Use With (Application) | Designed for liquid sampling to achieve the highest level of accuracy and precision possible, for use with HPLC injection valves and for sample pipetting |
| Max. Pressure | 6000 psi |
| Product Type | Microliter Syringe |
| Connection Type | Knurled Hub |
| Max. Temperature (English) | 239°F |
| Needle Point Style | Blunt |
| Length (English) Needle | 2.75 in. |
| Autoclavable | Autoclavable |
| Min. Temperature (Metric) | 10°C |
Thermo Scientific™ TriPlus RSH Autosampler Fixed GT Needle Syringe
Thermo Scientific™ TriPlus RSH Autosampler Fixed GT Needle Syringes are accurate and reproducible over a range of volumes.
| Connection Type | Fixed |
|---|---|
| Material | Stainless Steel (Needle),Stainless Steel (Plunger) |
| Length (Metric) Needle | 57 mm |
Thermo Scientific™ GC Syringe for CTC
Thermo Scientific™ Gastight GC Syringes are accurate and reproducible over a range of volumes.
Synthware™ Cannula
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Cannula for the transfer and handling of air sensitive materials.
| Color | Silver |
|---|---|
| Graduated | No |
| Quantity | 1 Ea. |
| Material | Stainless Steel |
| For Use With (Application) | Organic Synthesis |
| Sterility | Non-sterile |
SGE PTFE Fluorocarbon Resin-Tipped, Gas-Tight Syringes from Restek™
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Suitable for gases or liquids, for maximum inertness.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
| Product Type | SGE PTFE Tip, Gas-Tight Syringes |
|---|---|
| Quantity | Ea. |
| For Use With (Application) | Suitable for gases or liquids and high accuracy of dispensed volumes |
Hamilton™ 700 7000/1700 1000 Series Microliter™/Gastight™: N Termination
Syringes have built-in Chaney Adapters
| Includes | Built-in chaney adapter, small plunger wires |
|---|---|
| Needle Point Number | 2 |
| Length (Metric) | 51 mm |
| Max. Temperature (English) | 122°F |
| Length (English) | 2 in. |
| Needle Point Style | Sharp, Bevel, Curved, Non-coring |
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Length (English) Needle | 2 in. |
| Max. Temperature (Metric) | 50°C |
| For Use With (Application) | Designed for liquid sampling to achieve the highest level of accuracy and precision possible, recommended for septum penetration |
| Autoclavable | Not Autoclavable |
| Min. Temperature (Metric) | 10°C |
Hamilton™ 700/1700 Series Microliter/Gastight™ Syringes
Hamilton Company offers the most comprehensive selection of standard and custom syringes in the industry. Each is manufactured to achieve the highest level of accuracy and precision possible.
| Needle Point Number | No Needle Included |
|---|---|
| Product Type | Gastight Syringe |
| Connection Type | Removable |
| Max. Temperature (English) | 239°F |
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),PTFE (Tip),Stainless Steel (Plunger) |
| Max. Temperature (Metric) | 115°C |
| For Use With (Application) | Provides unprecedented functionality for controlled animal injections |
| Autoclavable | Autoclavable |
| Min. Temperature (Metric) | 10°C |
| Max. Pressure | 1000 psi |
Hamilton™ 700 Microliter™ Syringes: RN Termination
The 700 series syringe is the original hand-fitted Hamilton syringe. This series of syringes is ideal for dispensing volumes from 0.5 μL up to 500 μL. A variety of different terminations and needle options are available in this series.
| Needle Point Number | 2 |
|---|---|
| Length (Metric) | 51 mm |
| Product Type | Microliter Syringe |
| Connection Type | Removable |
| Max. Temperature (English) | 239°F |
| Length (English) | 2 in. |
| Needle Point Style | Sharp, Bevel, Curved, Non-coring |
| Min. Temperature (English) | 50°F |
| Material | PTFE (Tip),Stainless Steel (Plunger) |
| Length (English) Needle | 2 in. |
| Max. Temperature (Metric) | 115°C |
| For Use With (Application) | For dispensing low volumes to achieve the highest level of accuracy and precision possible |