GC Columns
Filtered Search Results
MilliporeSigma™ Supelco™ SPB™-624 Capillary GC Column, df 3 μm
Designed for purge-and-trap analyses of volatile halogenated, non-halogenated, and aromatic contaminants from environmental samples.
MilliporeSigma™ Supelco™ Carboxen™-1010 PLOT Capillary GC Column, df 15 μm
Porous-layer open-tubular (PLOT) columns are a powerful tool used in gas chromatography for analysis of fixed gases, light hydrocarbons and volatile solvents. They are mostly preferred over traditional columns.
MilliporeSigma™ Supelco™ β-DEX™ 110 Capillary GC Column, df 0.25 μm
Recommended for the enantiomeric separation of a wide range of chiral compounds (ketones, esters, alkanes, alkenes, alcohols, acids, ethers, etc.).
| Type | GC Accessories & Adsorbents |
|---|---|
| Packing Material | 10% permethylated β-cyclodextrin in SPB-35 poly(35% diphenyl/65% dimethylsiloxane) |
| Diameter (Metric) Inner | 0.25 mm |
| Material | Fused Silica |
| For Use With (Application) | Gas Chromatography (GC) |
| Film Thickness | 0.25 μm |
| Product Line | DEX |
MilliporeSigma™ Supelco™ Empty Glass GC Column, for Agilent™ 5880, 5890, 6890, 7820, and 7890 (Configuration A)
Empty column may be used for packing adsorbents for temperature-programmed desorption (TPD) instrumentation.
| Type | Empty GC |
|---|---|
| Packing Material | None |
| Material | Glass Column |
| For Use With (Application) | Gas Chromatography (GC) |
MilliporeSigma™ Supelco™ OVI-G43 Capillary GC Column, df 3 μm
Meets the requirements of United States Pharmacopoeia and European Pharmacopoeia methods for determining residual solvents in pharmaceutical preparations.
MilliporeSigma™ Supelco™ SPB™-5 Capillary GC Column, df 0.25 μm
This non-polar, general purpose column primarily provides a boiling point elution order with a slight increase in selectivity, especially for aromatic compounds.
Restek™ Rxi™-XLB Secondary Columns, Length: 2 m
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Convenient length is ideal for use as a secondary column in GCxGC analyses
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
| Stationary Phase | Rxi™-XLB |
|---|---|
| Length (Metric) | 2 m |
| Quantity | 1/Pk. |
| Polarity | Low |
| Coating | Fused Silica |
| Temperature Range (Metric) | 30°C to 360°C |
| For Use With (Application) | GCxGC Analyses |
Restek™ Rt-XLSulfur Micropacked Columns
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Optimized columns for low ppbv sulfur analyses. Restek Rt-XLSulfur Micropacked Columns eliminate the need for PTFE tubing.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
| Max. Temperature | 290°C |
|---|---|
| Stationary Phase | Rt™-XLSulfur |
| Packing Material | Rt™-XLSulfur |
| For Use With (Application) | GC |
Restek™ Rxi™-1301Sil MS Capillary Columns
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Columns with the highest thermal stability in the industry ensure dependable, accurate MS results and increased uptime
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
| Stationary Phase | Rxi™-1301Sil MS |
|---|---|
| Quantity | 1/Pk. |
| Polarity | Midpolar |
| Coating | Fused Silica |
| For Use With (Application) | Solvents, Glycols, and Other Polar Compounds Analysis |
| Max. Temperature (Metric) | 320°C |
Restek™ Rtx™-200 Secondary Columns, Length: 2 m
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Convenient length is ideal for use as a secondary column in GCxGC analyses
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
| Stationary Phase | Rtx™-200 |
|---|---|
| Length (Metric) | 2 m |
| Quantity | 1 |
| Polarity | Midpolar |
| Coating | Fused Silica |
| Temperature Range (Metric) | -20°C to +340°C |
| For Use With (Application) | GCxGC Analyses |
Restek™ GCxGC Selectivity Kits
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Wide range of stationary phases offers orthogonal separations
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
| Includes | Rxi™-1 MS Column, Rxi™-5Sil MS Column, Rxi™-XLB Column, Rxi™-17Sil MS Column, Rtx™-200 Column, Stabilwax™ Column, and Deactivated Universal Press-Tight Connectors (5/Pk.) |
|---|---|
| Stationary Phase | Various |
| Packing Material | Various |
| Quantity | 1 Kit |
| Coating | Fused Silica |
| For Use With (Application) | Orthogonal Separations Analysis |
Restek™ Stabilwax™ Secondary Columns, Length: 2 m
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Convenient length is ideal for use as a secondary column in GCxGC analyses
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
| Stationary Phase | Stabilwax™ |
|---|---|
| Length (Metric) | 2 m |
| Quantity | 1/Pk. |
| Polarity | Polar |
| Coating | Fused Silica |
| Temperature Range (Metric) | 40°C to 260°C |
| For Use With (Application) | GCxGC Analyses |
Restek™ Rtx™-1701 Capillary Columns - 60m Length
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
General-purpose, fused silica column for alcohols, oxygenates, PCB congeners, pesticides, and fragrance compounds.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
| Stationary Phase | Rtx™-1701 |
|---|---|
| Length (Metric) | 60 m |
| Polarity | Mid polar |
| Material | Stainless Steel |
| Coating | Fused Silica |
| Max. Temperature (Metric) | 350°C |
| Functionality/Interaction Type | Cyano and Phenyl |
| USP Type | G46 |
Restek™ Stabilwax™-DA Capillary Columns
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Similar in polarity to DB-FFAP, OV-351, NUKOL FFAP, HP FFAP
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
| Stationary Phase | Stabilwax™-DA |
|---|---|
| Polarity | Polar |
| Coating | Fused Silica |
| USP Type | G25, G35 |
Restek™ Rxi™-17Sil MS Secondary Columns, Length: 2 m
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Convenient length is ideal for use as a secondary column in GCxGC analyses
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
| Stationary Phase | Rxi™-17Sil MS |
|---|---|
| Length (Metric) | 2 m |
| Quantity | 1/Pk. |
| Polarity | Midpolar |
| Coating | Fused Silica |
| For Use With (Application) | Sensitive Detectors, Such as MS Analysis |
| Max. Temperature (Metric) | 340/360°C |