Test
Used for traditional general purpose applications, where a non-polar column is required.
Max. Temperature | -60°C to +300°C (isothermal or programmed) |
---|---|
Type | Capillary GC |
Packing Material | Poly(dimethyl siloxane) |
Diameter (Metric) Inner | 0.53 mm |
Polarity | Non-Polar |
Material | Fused Silica |
For Use With (Application) | Gas Chromatography (GC) |
Film Thickness | 1.5 μm |
USP Type | G1, G2, G9 |
Product Line | SPB |
Use Thermo Scientific™ TracePLOT TG-BOND Alumina GC Columns for linear and quantitative analysis of polar unsaturated hydrocarbons.
Max. Temperature | Up to 200°C |
---|---|
Stationary Phase | TracePLOT™ TG-BOND Alumina |
For Use With (Application) | Polar Unsaturated Hydrocarbons Analysis,GC for Unsaturated Hydrocarbon Isomers,Linear and Quantitative Analysis of Polar Unsaturated Hydrocarbons |
Choose these colums that feature a popular GCMS phase for many applications.
Stationary Phase | Trace™ TR-5 MS |
---|---|
Polarity | Non-Polar |
USP Type | G27, G36 |
Separate ethane, ethylene and acetylene consistently with the intermediate polarity PLOT column with essentially no particle release.
Max. Temperature | Up to 250°C |
---|---|
Stationary Phase | TracePLOT™ TG-BOND Q+ |
Polarity | Mid-Polar |
For Use With (Application) | GC for the Separation of Ethane, Ethylene, and Acetylene to Baseline |
Thermo Scientific™ TraceGOLD TG-XLBMS GC Columns offer a low polarity, low bleed column suitable for a wide range of applications.
Max. Temperature | 340/360°C |
---|---|
Stationary Phase | TraceGOLD™ TG-XLBMS |
Polarity | Low-Polar |
Analyze a wide range of polar compounds with this low-bleed, general purpose, high polarity GC column.
Stationary Phase | Trace™ TR-WAX |
---|---|
Polarity | Polar |
USP Type | G16, G20 |
Greater stability and inertness at elevated temperatures and when working with highly active compounds.
Max. Temperature | 330/350°C (Standard Columns), 430°C (Metal Columns) |
---|---|
Stationary Phase | TraceGOLD™ TG-5 MT |
Polarity | Low-Polar |
USP Type | G27, G36 |
An economical metal column should be used for less demanding applications where the inertness of glass is not required. This column is of a general configuration, and can be carefully bent to fit most instruments.
Max. Temperature | 330/360°C |
---|---|
Polarity | Mid-Polar |
USP Type | G42 |
Optimize volatile organics analysis with this low-bleed, midpolarity GC column with high thermal stability.
Useful for the analyses of volatile acidic compounds.
For Use With (Application) | Gas Chromatography (GC) |
---|---|
Film Thickness | 1 μm |
Product Line | Nukol |
Useful for analyses of polar analytes and provides useful confirmational information.
Max. Temperature | 30°C to 310°C (isothermal or programmed) |
---|---|
Type | Capillary GC |
Length (Metric) | 30 m |
Packing Material | Poly(50% diphenyl/50% dimethyl siloxane) |
Polarity | Polar |
Material | Fused Silica |
For Use With (Application) | Gas Chromatography (GC) |
Film Thickness | 0.25 μm |
USP Type | G3 |
Product Line | SPB |
Capillary column coated with SP™-2340 stationary phase may be used in gas chromatographic analysis and separation of cis/trans isomeric fatty acids.
Max. Temperature | Subambient to 250°C (isothermal or programmed) |
---|---|
Type | Capillary GC |
Packing Material | Poly(biscyanopropyl siloxane) |
Material | Fused Silica |
For Use With (Application) | Gas Chromatography (GC) |
Film Thickness | 0.20 μm |
USP Type | G5 |
Product Line | SP |
Capillary GC column is also known as open tubular column. The carrier gas flows through the central aperture and is unrestricted throughout the length of the column.
Useful for the analyses of volatile acidic compounds.
Type | Capillary GC |
---|---|
Packing Material | Acid-modified poly(ethylene glycol) |
Diameter (Metric) Inner | 0.53 mm |
Material | Fused Silica |
For Use With (Application) | Gas Chromatography (GC) |
Film Thickness | 0.50 μm |
Product Line | Nukol |