Industrial Hygiene and Environmental Monitoring
Filtered Search Results
Labconco™ Inflow and Downflow Sensor Kit
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Allows display of inflow and downflow velocities on the LCD information center on MyLogic™ Digital Display.
Thermo Scientific™ RAP Regulated Air Pumps
Compact, portable system containing an oilless vacuum pump, motor and airflow regulator ideal for collecting sampling media onto filters, or pulling airborne gases through active sampling systems, for radiological detection applications
Thermo Scientific™ AMS-4 Continuous Beta Air Monitors
Provides early warning to workers exposed to potential airborne releases of beta emitting particulates; lightweight and robust design accommodates both fixed and portable use applications
Mettler Toledo™ InLab™ 605-ISM Dissolved Oxygen Sensors
For use with the SevenExcellence™ bench meter and the SevenGo Pro™ portable instrument.
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID with Enhanced & Sampling Probes
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Width (English) | 9 in. |
|---|---|
| Response Time | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
| Detection Limits | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
| Width (Metric) | 22.9 cm |
| Detector Type | Dual Configured with FID and PID |
| Flow Rate | 1 L/min., nominal at sample probe inlet |
| Components Measured | Most Organic and Inorganic Compounds |
| Accuracy | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
| Battery Life | 10 hours at 0°C |
| Voltage | 120 V |
| Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Height (English) | 11.5 in. |
| Height (Metric) | 29.2 cm |
| Warranty | One year from date of shipment |
| Depth (English) | 4 in. |
| Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
| Battery Type | Lithium-ion |
| Repeatability | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
| Serial Interface | USB |
| Computer Requirements | USB port, Windows XP operating system or higher |
| Depth (Metric) | 10.2 cm |
| Fuel | 99.99% H2 for FID |
| Temperature Range (English) | 14°F to 113°F |
| Frequency | 50/60 Hz |
| Portable Operation Time | Minimum 10 hours |
| Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID (No Probes)
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Width (English) | 9 in. |
|---|---|
| Response Time | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
| Detection Limits | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
| Width (Metric) | 22.9 cm |
| Detector Type | Dual Configured with FID and PID |
| Flow Rate | 1 L/min., nominal at sample probe inlet |
| Components Measured | Most Organic and Inorganic Compounds |
| Accuracy | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
| Battery Life | 10 hours at 0°C |
| Voltage | 120 V |
| Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Height (English) | 11.5 in. |
| Height (Metric) | 29.2 cm |
| Warranty | One year from date of shipment |
| Depth (English) | 4 in. |
| Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
| Battery Type | Lithium-ion |
| Repeatability | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
| Serial Interface | USB |
| Computer Requirements | USB port, Windows XP operating system or higher |
| Depth (Metric) | 10.2 cm |
| Fuel | 99.99% H2 for FID |
| Temperature Range (English) | 14°F to 113°F |
| Frequency | 50/60 Hz |
| Portable Operation Time | Minimum 10 hours |
| Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID with Sampling Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Width (English) | 9 in. |
|---|---|
| Response Time | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
| Detection Limits | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
| Width (Metric) | 22.9 cm |
| Detector Type | Dual Configured with FID and PID |
| Flow Rate | 1 L/min., nominal at sample probe inlet |
| Components Measured | Most Organic and Inorganic Compounds |
| Accuracy | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
| Battery Life | 10 hours at 0°C |
| Voltage | 120 V |
| Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Height (English) | 11.5 in. |
| Height (Metric) | 29.2 cm |
| Warranty | One year from date of shipment |
| Depth (English) | 4 in. |
| Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
| Battery Type | Lithium-ion |
| Repeatability | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
| Serial Interface | USB |
| Computer Requirements | USB port, Windows XP operating system or higher |
| Depth (Metric) | 10.2 cm |
| Fuel | 99.99% H2 for FID |
| Temperature Range (English) | 14°F to 113°F |
| Frequency | 50/60 Hz |
| Portable Operation Time | Minimum 10 hours |
| Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only (No Probes)
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Width (English) | 9 in. |
|---|---|
| Response Time | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
| Detection Limits | 0.5 ppm of methane |
| Width (Metric) | 22.9 cm |
| Detector Type | Flame Ionization Detector (FID) |
| Flow Rate | 1 L/min., nominal at sample probe inlet |
| Components Measured | Most Organic and Inorganic Compounds |
| Accuracy | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
| Battery Life | 10 hours at 0°C |
| Voltage | 120 V |
| Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Height (English) | 11.5 in. |
| Height (Metric) | 29.2 cm |
| Warranty | One year from date of shipment |
| Depth (English) | 4 in. |
| Concentration | 0 to 30,000 ppm (methane) |
| Battery Type | Lithium-ion |
| Repeatability | ±2% at 500 ppm of methane |
| Serial Interface | USB |
| Computer Requirements | USB port, Windows XP operating system or higher |
| Depth (Metric) | 10.2 cm |
| Fuel | 99.99% H2 for FID |
| Temperature Range (English) | 14°F to 113°F |
| Frequency | 50/60 Hz |
| Portable Operation Time | Minimum 10 hours |
| Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ RadEye SPRD with Large Display
Pocket-sized Personal Radiation Detector includes CSI gamma detector with integral SPM.
Thermo Scientific™ RadEye™ GN+ Gamma Neutron Pager
Be warned of rising levels of gamma and neutron radiation as soon as it occurs with radiation detection devices for nuclear search and emergency response operations.
| Height (Metric) | 96 mm |
|---|---|
| Depth (English) | 1.2 in. |
| Width (English) | 2.4 in. |
| Width (Metric) | 61 mm |
| Sensitivity | Gamma (0.01μSv/h-250μSv/h), Neutron (0.1-1000 cps) |
| Battery Life | >300 hr. |
| Product Type | Gamma Neutron Pager |
| Depth (Metric) | 31 mm |
| Neutron Response | Neutron count-rate: from 0,1 to 1000 cps; Neutron efficiency: 4.3 cps/20,000 n/s Cf-252; shielded in 1cm lead 25cm in front of instrument with 30 x 30 x 15cm PMMA phantom |
| Weight (English) | 5.6 oz. |
| Certifications/Compliance | Exceeds ANSI 42.32 and IEC 62401 alarm requirements |
| Radiation Type | Gamma, Neutron |
| Weight (Metric) | 160 g |
| Height (English) | 3.8 in. |
Thermo Scientific™ RadEye™ AB100 Alpha-Beta Contamination Monitor
Quickly detect alpha and beta radiation contamination in nuclear power plants, hospitals, medical centers and in security and first responder applications.
Thermo Scientific™ RadEye™ B20 and B20-ER Multi-Purpose Survey Meters
Quickly characterize mixed surface contamination from gamma radiation, x-ray radiation, alpha radiation and beta radiation with dose rate measurement survey meters.
| Height (Metric) | 13 cm |
|---|---|
| Depth (English) | 2.4 in. |
| Diameter (Metric) Window | 44 mm |
| Length (Metric) | 13 cm |
| Width (English) | 2.8 in. |
| Length (English) | 5.2 in. |
| Width (Metric) | 7 cm |
| Battery Type | 2 AAA |
| Units | cps, cpm. Bq, dpm, dps, Sv/h, rem/h |
| Alarm Types | LED, sound, vibrator |
| Battery Life | >500 hr.s on two AAA batteries |
| Diameter (English) Window | 1.7 in. |
| Dimensions (L x W x H) | 5.2 x 2.8 x 5.2 in. (13 x 7 x 13 cm) |
| Efficiency | 2p Efficiency (ref. to 50 mm diameter without rubber sleeve): Am-241; Co-60: 25%; Sr/Y-90: 36%; C-14: 19% |
| Product Type | Survey Meter |
| Depth (Metric) | 6 mm |
| Weight (English) | 0.7 lb. |
| Radiation Type | Gamma |
| Weight (Metric) | 0.3 kg |
| Height (English) | 5.2 in. |
| Measurement Range | Contamination B-20: 0 - 10 kcps; B20ER: 0 - 500 kcps |
Thermo Scientific™ FH 40 G Multi-Purpose Digital Survey Meter
Use one convenient, versatile instrument for multiple radiation detection applications including personal radiation protection and beta, x-ray and gamma radiation detection.