General Spectrometer Accessories
- (1)
- (1)
- (1)
- (1)
- (2)
- (5)
- (5)
- (5)
- (14)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (10)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (3)
Filtered Search Results
Glass Expansion RF Coil Gold for Varian Series 2 Axial.
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
RF Coil Gold for Agilent (Varian) Liberty Series 2 and Vista Axial ICP-OES. Compatible with Agilent (Varian) Liberty Series 2 and Vista Axial ICP-OES. The RF coil is susceptible to corrosion in the torch box, which eventually lowers the conductivity of the coil. The greater the corrosion, the larger amount of energy is needed to produce a plasma of the same power. Coils in a corroded condition, increases the stress applied to other components in the RF generating system, and can shorten the lifetime of your torch. Copper is used as the base material of most commercially available coils but different plating materials are available. Silver has the best conductance & gold the best corrosion resistance. For Silver 501907309 and PTFE Coated Silver 501907310.To install your coil and ensure proper alignment, we highly recommend our re-useable RF Coil Installation Tool Kit (501907311).Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion RF Coil Installation Tool for Varian Series 2 Axial, Suitable for: Liberty Series 2 and Vista.
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
RF Coil Installation Tool for Agilent (Varian) Liberty Series 2 and Vista Axial ICP-OES. This tool is for use with all Glass Expansion’s replacement RF Coils for Agilent (Varian) Liberty Series 2 and Vista Axial ICP-OES, P/Ns 501907308, 501907309 and 501907310. To install your RF coil and ensure proper alignment, we highly recommend using our re-useable RF Coil Installation Tool Kit.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion DuraMist DC Nebulizer 1mL/min, Includes NFT-050 UniFit Connector with 0.50mm ID x 1.3mm OD x 700mm long tubing (1 piece) and 70-803-0969 Gas Fitting with Ratchet Nebulizer connector
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
DuraMist DC Nebulizer 1.0mL/min, includes UniFit Connector with 0.50mm ID x 1.3mm OD x 700mm long tubing (1 pc) and DC Gas Fitting Type 11 with ratchet connector (1 pc). Compatible with Analytik Jena ICP-MS and Leeman.Optimum nebulizer gas flow rate is 1.0L/min & sample flow rate is 1.0mL/min. Recommended not to exceed optimum 1.0mL/min sample flow rate; however, lower gas & sample flow rates are OK. The backpressure should read ~40 psi at 1.0L/min gas flow rate. DuraMist is an economical inert nebulizer for high-precision analysis & the highest tolerance to TDS, up to 30%. Made from PEEK, it tolerates up to 5% HF.Replacement parts include P/Ns NC1625341 and 502703076.Recommend nebulizer maintenance tools are Fluka RBS25 (P/N NC9000117) & Eluo Nebulizer Cleaning Tool (P/N 501907353). When nebulizer is not in use, best to store in the provided hard plastic case.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion RF Coil Gold for Optima 2000/4000/5000/7000. To ensure correct installation, the Installation Kit 70-900-2003T is required. This is not included and must be ordered separately. It is re-useable so only needs to be ordered once.
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
RF Coil Gold for PerkinElmer Optima 2000/4000/5000/7000 DV Series ICP-OES. Compatible with PerkinElmer Optima 2000/4000/5000/7000 DV Series ICP-OES. The RF coil is susceptible to corrosion in the torch box, which eventually lowers the conductivity of the coil. The greater the corrosion, the larger amount of energy is needed to produce a plasma of the same power. Coils in a corroded condition, increases the stress applied to other components in the RF generating system, and can shorten the lifetime of your torch. Copper is used as the base material of most commercially available coils but different plating materials are available. Silver has the best conductance & gold the best corrosion resistance. For Silver 501907328.To install your coil and ensure proper alignment, we highly recommend our re-useable RF Coil Installation Tool Kit (501907329).Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion RF Coil Silver for 700-ES Series Axial
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
RF Coil Silver for Agilent (Varian) 700-ES Series Axial ICP-OES. Compatible with Agilent (Varian) 700-ES Series Axial ICP-OES. The RF coil is susceptible to corrosion in the torch box, which eventually lowers the conductivity of the coil. The greater the corrosion, the larger amount of energy is needed to produce a plasma of the same power. Coils in a corroded condition, increases the stress applied to other components in the RF generating system, and can shorten the lifetime of your torch. Copper is used as the base material of most commercially available coils but different plating materials are available. Silver has the best conductance & gold the best corrosion resistance. For Gold 501907319, PTFE Coated Silver 501907321.To install your coil and ensure proper alignment, we highly recommend our re-useable RF Coil Installation Tool Kit (501907322).Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion MicroMist DC Nebulizer 0.4mL/min, Includes NFT-16-50 UniFit Connector with 0.50mm ID x 1.6mm OD x 700mm long tubing (1 piece) and 70-803-1086 Gas Fitting with Ratchet Nebulizer connector
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
MicroMist DC Nebulizer 0.4 mL/min, includes UniFit Connector with 0.50mm ID x 1.6mm OD x 700mm long tubing (1 pc.) and DC Gas Fitting Type 12 with ratchet connector (1 pc.). Compatible with Agilent 4500/7500 ICP-MS.Optimum nebulizer gas flow rate is 1.0L/min and sample flow rate is 0.4mL/min. Recommended not to exceed optimum 0.4mL/min sample flow rate; however, lower gas and sample flow rates are OK. The backpressure should read ~40 psi at 1.0L/min gas flow rate. Can tolerate up to 15% TDS. MicroMist is the standard configuration for many ICP manufacturers due to its excellent sensitivity and precision at low flow rates. Replacement parts include P/Ns 502702959 and 501907288.Recommend maintenance tools are Fluka RBS25 (P/N NC9000117) and Eluo Nebulizer Cleaning Tool (P/N NC9462559). When not in use, best to store in the provided hard plastic case.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion SeaSpray DC Nebulizer 0.4mL/min, Includes NFT-050 UniFit Connector with 0.50mm ID x 1.3mm OD x 700mm long tubing (1 piece) and 70-803-0969 Gas Fitting with Ratchet Nebulizer connector
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
SeaSpray DC Nebulizer 0.4 mL/min, includes UniFit Connector with 0.50mm ID x 1.3mm OD x 700mm long tubing (1 piece) and DC Gas Fitting Type 11 with ratchet connector (1 pc.). Compatible with Analytik Jena ICP-MS and Leeman.Optimum nebulizer gas flow rate is 1.0 L/min and sample flow rate is 0.4 mL/min. Recommended not to exceed optimum 0.4 mL/min sample flow rate; however, lower gas and sample flow rates are OK. The backpressure should read approximately 40 psi at 1.0 L/min gas flow rate. Can tolerate up to 20% TDS. We recommend the use of the Elegra Argon Humidifier to achieve best performance with high TDS.Replacement parts include P/Ns NC1625341 and 502703076.Recommend nebulizer maintenance tools are Fluka RBS25 (P/N NC9000117) and Eluo Nebulizer Cleaning Tool (P/N NC9462559). When nebulizer is not in use, best to store in the provided hard plastic case.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Shimadzu ICPE 9800 Installation Tool
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
RF Coil Installation Tool for Shimadzu ICPE 9800 ICP-OES. This tool is for use with all Glass Expansion’s replacement RF Coils for Shimadzu ICPE 9800 ICP-OES, P/Ns 501907340, 501907341 and 501907342. To install your RF coil and ensure proper alignment, we highly recommend using our re-useable RF Coil Installation Tool Kit.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion RF Coil Gold for 700-ES Series Radial
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
RF Coil Gold for Agilent (Varian) 700-ES Series Radial ICP-OES. Compatible with Agilent (Varian) 700-ES Series Radial ICP-OES. The RF coil is susceptible to corrosion in the torch box, which eventually lowers the conductivity of the coil. The greater the corrosion, the larger amount of energy is needed to produce a plasma of the same power. Coils in a corroded condition, increases the stress applied to other components in the RF generating system, and can shorten the lifetime of your torch. Copper is used as the base material of most commercially available coils but different plating materials are available. Silver has the best conductance & gold the best corrosion resistance. For Silver 501907324, PTFE Coated Silver 501907325.To install your coil and ensure proper alignment, we highly recommend our re-useable RF Coil Installation Tool Kit (501907326).Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion MicroMist DC Nebulizer 0.4mL/min, Includes NFT-050 UniFit Connector with 0.50mm ID x 1.3mm OD x 700mm long tubing (1 piece) and 70-803-0969 Gas Fitting with Ratchet Nebulizer connector
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
MicroMist DC Nebulizer 0.4 mL/min, includes UniFit Connector with 0.50mm ID x 1.3mm OD x 700mm long tubing (1 pc.) and DC Gas Fitting Type 11 with ratchet connector (1 pc.). Compatible with Analytik Jena ICP-MS and Leeman.Optimum nebulizer gas flow rate is 1.0L/min and sample flow rate is 0.4mL/min. Recommended not to exceed optimum 0.4mL/min sample flow rate; however, lower gas and sample flow rates are OK. The backpressure should read ~40 psi at 1.0L/min gas flow rate. Can tolerate up to 15% TDS. MicroMist is the standard configuration for many ICP manufacturers due to its excellent sensitivity and precision at low flow rates. Replacement parts include P/Ns NC1625341 and 502703076.Recommend maintenance tools are Fluka RBS25 (P/N NC9000117) and Eluo Nebulizer Cleaning Tool (P/N NC9462559). When not in use, best to store in the provided hard plastic case.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion RF Coil Silver PTFE Coated for Varian Series 2 Axial rdered once.
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
RF Coil Silver PTFE Coated for Agilent (Varian) Liberty Series 2 and Vista Axial ICP-OES. Compatible with Agilent (Varian) Liberty Series 2 and Vista Axial ICP-OES. The RF coil is susceptible to corrosion in the torch box, which eventually lowers the conductivity of the coil. The greater the corrosion, the larger amount of energy is needed to produce a plasma of the same power. Coils in a corroded condition, increases the stress applied to other components in the RF generating system, and can shorten the lifetime of your torch. Copper is used as the base material of most commercially available coils but different plating materials are available. Silver has the best conductance & gold the best corrosion resistance. For Gold 501907308 and Silver 501907309.To install your coil and ensure proper alignment, we highly recommend our re-useable RF Coil Installation Tool Kit (501907311).Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion OpalMist Nebulizer 2mL/min, Includes NFT-16-75 UniFit Connector with 0.75mm ID x 1.6mm OD x 700mm long tubing (1 piece), EL-1 EzyLok Connector Kit, and 70-803-0911 Ratchet EzyLok Connector
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
OpalMist U-Series Nebulizer 2.0mL/min, includes UniFit Connector with 0.75mm ID x 1.6mm OD x 700mm long tubing (1 pc) & EzyLok Connector (1 pc).Optimum nebulizer gas flow rate is 1.0L/min & sample flow rate is 2.0mL/min. Recommended not to exceed optimum 2.0mL/min sample flow rate; however, lower gas & sample flow rates are OK. The backpressure should read ~40 psi at 1.0L/min gas flow rate. OpalMist is made from high purity PFA resulting in the lowest background & exceptional resistance to HF. Tolerates up to 15% TDS & 75um particulates.Replacement parts include P/Ns NFT-16-75, 502702994 & 501907289.Recommended nebulizer maintenance tools, Fluka RBS25 (P/N NC9000117) & Eluo Nebulizer Cleaning Tool (P/N 501907353). When nebulizer is not in use, store in the provided hard plastic case.Consider upgrading to our new Direct Connect (DC) OpalMist to take advantage of the cost-effective design improvements.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion MicroMist DC Nebulizer 0.4mL/min, Includes NFT-16-50 UniFit Connector with 0.50mm ID x 1.6mm OD x 700mm long tubing (1 piece) and 70-803-1449 Gas Fitting with Ratchet Nebulizer connector
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
MicroMist DC Nebulizer 0.4 mL/min, includes UniFit Connector with 0.50mm ID x 1.6mm OD x 700mm long tubing (1 pc.) and DC Gas Fitting Type 23 with ratchet connector (1 pc.). Compatible with Perkin Elmer NexION 1000/2000/5000.Optimum nebulizer gas flow rate is 1.0L/min and sample flow rate is 0.4mL/min. Recommended not to exceed optimum 0.4mL/min sample flow rate; however, lower gas and sample flow rates are OK. The backpressure should read ~40 psi at 1.0L/min gas flow rate. Can tolerate up to 15% TDS. MicroMist is the standard configuration for many ICP manufacturers due to its excellent sensitivity and precision at low flow rates. Replacement parts include P/Ns 502702959 and 501907305.Recommend maintenance tools are Fluka RBS25 (P/N NC9000117) and Eluo Nebulizer Cleaning Tool (P/N NC9462559). When not in use, best to store in the provided hard plastic case.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
MilliporeSigma Direct Detect Assay-free Cards, 50/pk
50 Membrane cards used for protein quantitation in the Direct Detect Infrared Spectrometer.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
MSC CTN/POLY CARPET BONNET
17" LOOP W/SCRUB STRIP CTN/POLY CARPET BONNET
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More