Thermo Scientific™ Hypersil™ CPS-2 Cyano LC Columns Available on GSA/VA Contract for Federal Government customers only.

Use these cyano columns when you need different selectivity in normal phase or a complementary selectivity to alkyl chain bonded phases in reverse phase.

Manufacturer: Thermo Scientific™ 31805014001

 View more versions of this product

Catalog No. 31-805-014001

  Check Availability
Add to Cart

    Specifications

    Column Type Normal Phase
    Type Guard Cartridge, 4 PK
    Carbon Load 4%
    USP Type L10
    Endcapped Yes
    Max. Pressure 400bar
    Particle Size 5µm
    Temperature 60°C
    Pore Size 120Å
    pH 2 to 8
    Stationary Phase Cyano
    Surface Area 170m²/g
    Length (Metric) 10mm
    Column Format Guard Cartridge, 4 PK
    Diameter (Metric) 4mm

    When you need different selectivity in normal phase or a complementary selectivity to alkyl chain bonded phases in reverse phase, use Thermo Scientific™ Hypersil™ CPS-2 Cyano LC Columns. Hypersil stationary phases are recognized as an industry standard in HPLC. Proven as an effective analytical tool, classical Hypersil phases are well established and referenced in HPLC methods. Quality is assured by manufacture under ISO 9001-2000 quality guidelines. For challenging separations requiring improved chromatographic performance, use Hypersil GOLD™ CN columns as an alternative.

    Features of CPS-2 Solid Phase

    • Operates in both normal and reversed phase modes
    • More rapid mobile phase equilibration compared with silica in normal phase
    • Not deactivated by traces of water in normal phase
    • When used as a reversed phase material, cyano selectivity complements the alkyl chain bonded phases, but with lower hydrophobicity
    • One of the least retentive of reversed phase materials and, therefore, useful to separate polar compounds