Syringes for manual or autosampler injections, in a variety of sizes, needle gauges, point styles, and terminations; includes electronic and manual gas tight syringes, HPLC general syringes, and replacement parts and accessories. Choose from leading brands for analytical gas and liquid syringes. Specialty syringes designed for unique applications are also available.
Filtered Search Results
Hamilton™ 700 Microliter Syringes: N Termination
The 700 series syringe is the original hand-fitted Hamilton syringe. This series of syringes is ideal for dispensing volumes from 0.5 μL up to 500 μL. A variety of different terminations and needle options are available in this series.
| Product Type | Microliter Syringe |
|---|---|
| Length (English) Needle | 2 in. |
| For Use With (Application) | For dispensing low volumes to achieve the highest level of accuracy and precision possible |
| Autoclavable | Not Autoclavable |
Hamilton™ Microliter™ and Gastight™ Syringes Model 1701N For Agilent 7673, 7683, 7693 and 6850 ALS GC
Designed to work with Agilent 7673, 7683, 7693 and 6850 Automatic Liquid Sampler (ALS) gas chromatography (GC) autosamplers
| Needle Point Number | AS |
|---|---|
| Diameter (English) Inner | 0.018 in. |
| Length (Metric) | 43 mm |
| Volume (Metric) | 10 μL |
| Length (English) | 1.7 in. |
| Diameter (Metric) Inner | 0.46 mm |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger) |
| Max. Pressure | 1000 psi |
| For Use With (Equipment) | Agilent 7673, 7683, 6850 Automatic Liquid Sampler, Gas Chromatography Autosamplers |
| Product Type | Gastight Syringe |
| Diameter (Metric) Outer | 6.6 mm |
| Diameter (English) Outer | 0.26 in. |
| Needle Point Style | Cone |
| Length (English) Needle | 1.71 in. |
| Min. Temperature (Metric) | 10°C |
Hamilton™ 800 Microliter™ Syringes, N Termination
Attached to the flange of the 700 series syringe is a blue Syringe Holder that provides a spot to hold the syringe that will not heat up the barrel causing dispense inaccuracies. Additionally it provides support to small volume plungers that are prone to bending during injection. This series of syringes is ideal for dispensing volumes from 0.5 μL up to 250 μL.
| Needle Point Number | 2 |
|---|---|
| Length (Metric) | 51 mm |
| Length (English) | 2 in. |
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger) |
| Max. Temperature (Metric) | 50°C |
| For Use With (Application) | Ideal for dispensing liquid to achieve the highest level of accuracy and precision possible, recommended for septum penetration |
| Max. Pressure | 2000 psi |
| Includes | Removable blue syringe holder |
| Product Type | Microliter Syringe |
| Connection Type | Cemented |
| Max. Temperature (English) | 122°F |
| Needle Point Style | Sharp, Bevel, Curved, Non-coring |
| Length (English) Needle | 2 in. |
| Autoclavable | Not Autoclavable |
| Min. Temperature (Metric) | 10°C |
Hamilton™ 1000 Series Gastight™ Syringes: Luer Lock Syringes, TLL Termination
Mid-volume GASTIGHT syringe ideal for dispensing volumes from 100 μL up to 100 mL.
| Needle Point Number | No Needle Included |
|---|---|
| Product Type | Gastight Syringe |
| Quantity | Ea. |
| For Use With (Application) | Ideal for manual and automated HPLC injections, commonly used in syringe pumps and other liquid handling instruments |
Hamilton™ Large Hub Removable Needles (250μL - 10mL Syringes)
Large Hub Removable (RN) needles can be used with removable needle (RN)-style syringes that are 250μL and larger. Standard needle length is 2 in. (51mm). Custom gauges, lengths, and point styles are available.
| For Use With (Equipment) | Removable Syringes (250μL and larger) |
|---|---|
| Product Type | Replacement Syringe Needle |
| Material | Stainless Steel (Hub) |
| Length (English) Needle | 2 in. |
| Autoclavable | Autoclavable |
Hamilton™ CTC LEAP PAL COMBI-xt HDHT Headspace Syringes
Operate leak-free thanks to a dynamic seal created by a spring-in-plunger design. Hamilton™ CTC LEAP PAL COMBI HDHT Headspace Syringes feature the high dynamic HD plunger which compensates for different expansion coefficients, creating a better seal over a larger range of temperatures.
| Length (Metric) | 50.8 mm |
|---|---|
| For Use With (Equipment) | CTC LEAP CombiPAL Autosampler |
| Product Type | Gastight, Headspace Syringe |
| Connection Type | Glue-Free |
| Max. Temperature (English) | 392°F |
| Length (English) | 2 in. |
| Needle Point Style | 5 |
| Quantity | 1/Pk. |
| Min. Temperature (English) | 68°F |
| Max. Temperature (Metric) | 200°C |
| Autoclavable | Not Autoclavable |
| Min. Temperature (Metric) | 20°C |
| Max. Pressure | 29 psig (2 bar) |
Thermo Scientific™ TriPlus RSH Autosampler Fixed Needle Syringe, 5μL
Thermo Scientific™ TriPlus RSH Autosampler Fixed Needle Syringes are accurate and reproducible over a range of volumes.
MilliporeSigma™ Supelco™ SGE Syringes, Cone Tip
For use with Agilent/HP 7673, 7683 and 6850 ALS Autosamplers
| Needle Point Number | 1 |
|---|---|
| For Use With (Equipment) | Agilent 7673, 7683, 6850 ALS Autosampler |
| Product Type | SGE Syringe |
| Needle Point Style | Cone |
| Material | Stainless Steel (Tip) |
| Length (Metric) Needle | 42 mm |
Valco™ Precision Sampling Syringe, Magnum Series, Sold by MilliporeSigma™ Supelco™
Ideal for collection, trace analysis, and sample concentration of environmental contaminants
| Description | Magnum Series |
|---|---|
| Product Type | Precision Sampling Syringe |
| Connection Type | Removable |
| Needle Point Style | Bevel |
| Quantity | 1 Ea. |
| Material | Borosilicate Glass (Barrel) |
| Length (English) Needle | 2 in. |
| For Use With (Application) | Collection, Trace Analysis and Sample Concentration of Environmental Contaminants |
| Diameter (English) Outer Needle | 0.035 in. |
| Diameter (English) Inner Needle | 0.023 in. |
| Product Line | Valco |
Hamilton™ 1000 Series Syringe, 5 mL, Sold by MilliporeSigma™ Supelco™
Designed for analyzing drinking water samples according US EPA Purge and Trap Concentration Techniques (EPA Methods 502.1, 502.2, 503.1, 524.1, and 524.2)
| Diameter (English) Inner | 0.406 in. |
|---|---|
| Volume (Metric) | 5 mL |
| Diameter (Metric) Inner | 10.3 mm |
| Quantity | 1 Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),PTFE (Plunger) |
| Max. Temperature (Metric) | 115°C |
| For Use With (Application) | Analyzing Drinking Water Samples |
| Max. Pressure | 200 psig (13.8 bar) |
| Product Type | Gastight™ Syringe |
| Diameter (Metric) Outer | 13.5 mm |
| Max. Temperature (English) | 239°F |
| Diameter (English) Outer | 0.530 in. |
| Autoclavable | Autoclavable |
| Min. Temperature (Metric) | 10°C |
| Product Line | Hamilton |
Hamilton™ 1000 Series Syringe, Fixed Needle with Side Port, Sold by MilliporeSigma™ Supelco™
Gas-tight design minimizes gas exchange during GC analysis. Syringes provide accurate volume delivery with a plunger that is mostly unsurpassed.
| Needle Point Number | 5 |
|---|---|
| Quantity | 1 Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),PTFE (Plunger),Stainless Steel (Tip) |
| Max. Temperature (Metric) | 50°C |
| Length (Metric) Needle | 51 mm |
| Max. Pressure | 200 psig (13.8 bar) |
| Diameter (Metric) Inner Needle | 0.41 mm |
| Product Type | Gastight™ Syringe |
| Connection Type | Luer Tip, Cemented |
| Max. Temperature (English) | 122°F |
| Needle Point Style | Cone with Side Port |
| Diameter (Metric) Outer Needle | 0.72 mm |
| Length (English) Needle | 2 in. |
| Autoclavable | Not Autoclavable |
| Min. Temperature (Metric) | 10°C |
| Needle Gauge | 22 G |
| Diameter (English) Outer Needle | 0.0283 in. |
| Diameter (English) Inner Needle | 0.0161 in. |
| Product Line | Hamilton |
Hamilton™ TLC Syringes, PTFE-Coated Tip, Sold by MilliporeSigma™ Supelco™
PTFE coats the final 3/4 in. of this 2 in. cemented needle to allow for more reproducible sample spotting on TLC plates
| Needle Point Number | 3 T |
|---|---|
| Quantity | 1 Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),PTFE-coated Stainless Steel (Tip) |
| Max. Temperature (Metric) | 50°C |
| Length (Metric) Needle | 51 mm |
| Max. Pressure | 1000 psig (68.9 bar) |
| Product Type | Gastight™ Syringe |
| Connection Type | Cemented |
| Max. Temperature (English) | 122°F |
| Needle Point Style | Coated Tip |
| Length (English) Needle | 2 in. |
| Autoclavable | Not Autoclavable |
| Min. Temperature (Metric) | 10°C |
| Product Line | Hamilton |
Hamilton™ 1000 Series Syringe, Without Needle, Sold by MilliporeSigma™ Supelco™
Gas-tight design minimizes the gas exchange in GC analysis. Syringes provide accurate volume delivery with a plunger that is mostly unsurpassed. Tip is threaded in a luer lock syringe which allows the needle to be tightly screwed to the tip.
| Product Type | Gastight™ Syringe |
|---|---|
| Quantity | 1 Ea. |
| Product Line | Hamilton |
Synthware™ Microliter Sample Syringes - Liquid Phase
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Borosilicate syringes with a blunt tip, for precise sample delivery in volumes ranging from 0.5 μL to 1 mL.
| Disposable | Reusable |
|---|---|
| For Use With (Equipment) | Syringe Needles |
| Product Type | Syringe |
| Connection Type | Slip Tip |
| Color | Clear |
| Graduated | Yes |
| Needle Point Style | Blunt |
| Latex Free | Yes |
| Material | Borosilicate Glass (3.3) |
| For Use With (Application) | Precise Sampling |
| Sterility | Non-sterile |
Thermo Scientific™ GC Syringes for TriPlus™ RSH Autosampler
Easily accomplish accurate, precise, and reproducible injections with Thermo Scientific™ GC Syringes for Thermo Scientific™ TriPlus™ RSH Autosampler.