Chromatography Syringes
Syringes for manual or autosampler injections, in a variety of sizes, needle gauges, point styles, and terminations; includes electronic and manual gas tight syringes, HPLC general syringes, and replacement parts and accessories. Choose from leading brands for analytical gas and liquid syringes. Specialty syringes designed for unique applications are also available.
Filtered Search Results
Hamilton™ Microliter™ and Gastight™ Syringes Model 1701N For Agilent 7673, 7683, 7693 and 6850 ALS GC
Designed to work with Agilent 7673, 7683, 7693 and 6850 Automatic Liquid Sampler (ALS) gas chromatography (GC) autosamplers
| Needle Point Number | AS |
|---|---|
| Diameter (English) Inner | 0.018 in. |
| Length (Metric) | 43 mm |
| Volume (Metric) | 10 μL |
| Length (English) | 1.7 in. |
| Diameter (Metric) Inner | 0.46 mm |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger) |
| Max. Pressure | 1000 psi |
| For Use With (Equipment) | Agilent 7673, 7683, 6850 Automatic Liquid Sampler, Gas Chromatography Autosamplers |
| Product Type | Gastight Syringe |
| Diameter (Metric) Outer | 6.6 mm |
| Diameter (English) Outer | 0.26 in. |
| Needle Point Style | Cone |
| Length (English) Needle | 1.71 in. |
| Min. Temperature (Metric) | 10°C |
Hamilton™ 700 Microliter Syringes: N Termination
The 700 series syringe is the original hand-fitted Hamilton syringe. This series of syringes is ideal for dispensing volumes from 0.5 μL up to 500 μL. A variety of different terminations and needle options are available in this series.
| Product Type | Microliter Syringe |
|---|---|
| Length (English) Needle | 2 in. |
| For Use With (Application) | For dispensing low volumes to achieve the highest level of accuracy and precision possible |
| Autoclavable | Not Autoclavable |
Hamilton™ Modified 7000 Microliter™ Syringes
This series of syringes is ideal for dispensing volumes from 0.05 μL up to 5 μL. The 7000 series is the only zero dead volume syringe. The fine gauge plunger wire travels to the tip of the needle ensuring that all solvent is expelled from the needle.
| Product Type | General Purpose Syringe |
|---|---|
| Diameter (Metric) Outer | 7.82 mm |
| Connection Type | Knurled Hub, Removable |
| Max. Temperature (English) | 239°F |
| Diameter (English) Outer | 0.3 in. |
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Length (English) Needle | 2.75 in. |
| Max. Temperature (Metric) | 115°C |
| Autoclavable | Autoclavable |
| Min. Temperature (Metric) | 10°C |
| Diameter (English) Outer Needle | 0.02 in. |
Hamilton™ 1000 Series Gastight™ Syringes: Fixed-Needle Syringes, LTN Termination, 22 Gauge, 2 in. Needle Length
Mid-volume GASTIGHT syringe ideal for dispensing volumes from 100 μL up to 100 mL. A variety of different terminations and needle options are available in this series.
| Diameter (Metric) Inner Needle | 0.41 mm |
|---|---|
| Product Type | Gastight Syringe |
| Connection Type | Luer Tip, Cemented |
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Diameter (Metric) Outer Needle | 0.72 mm |
| Material | Borosilicate Glass (Barrel),PTFE (Tip),Stainless Steel (Plunger) |
| Length (English) Needle | 2 in. |
| For Use With (Application) | Ideal for manual and automated HPLC injections, commonly used in syringe pumps and other liquid handling instruments |
| Needle Gauge | 22 G |
| Max. Pressure | 200 psi |
| Diameter (English) Outer Needle | 0.028 in. |
| Diameter (English) Inner Needle | 0.016 in. |
Hamilton™ 1000 Series Gastight™ Syringes: Luer Lock Syringes, TLL Termination
Mid-volume GASTIGHT syringe ideal for dispensing volumes from 100 μL up to 100 mL.
| Needle Point Number | No Needle Included |
|---|---|
| Product Type | Gastight Syringe |
| Quantity | Ea. |
| For Use With (Application) | Ideal for manual and automated HPLC injections, commonly used in syringe pumps and other liquid handling instruments |
Hamilton™ 700 7000/1700 1000 Series Microliter™/Gastight™: TLL Termination
Syringes have built-in Chaney Adapters
| Needle Point Number | No Needle Included |
|---|
Hamilton™ 1001LTN Syringes, Sold by MilliporeSigma™ Supelco™
A 1 mL Gastight syringe, available in a variety of different terminations and needle options
| Product Type | Gastight™ Syringe |
|---|---|
| Connection Type | Luer Tip, Cemented |
| Max. Temperature (English) | 122°F |
| Volume (Metric) | 1 mL |
| Packaging | Individually Packaged |
| Model | 1001 LTN |
| Quantity | 1 Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),PTFE (Plunger),Stainless Steel (Tip) |
| Max. Temperature (Metric) | 50°C |
| Autoclavable | Not Autoclavable |
| Min. Temperature (Metric) | 10°C |
| Product Line | Hamilton |
Thermo Scientific™ Manual, Removable-Needle, Gas Tight Syringes for GC Instruments
Use Thermo Scientific™ Removable Needle Syringes for accurate and reproducible manual sample introduction into GC instruments, with or without the needle.
| Length (Metric) | 50 mm |
|---|---|
| Quantity | 1/Ea. |
| Length (Metric) Needle | 50 mm |
Hamilton™ Gastight™ Syringe, 500 μL, Sold by MilliporeSigma™ Supelco™
Gas-tight design minimizes gas exchange during GC analysis. Syringes provide accurate volume delivery with a plunger that is mostly unsurpassed.
| Product Type | Gastight™ Syringe |
|---|---|
| Quantity | 1 Ea. |
| Max. Pressure | 700 psig (48.3 bar) |
| Product Line | Hamilton |
Hamilton™ 1000 Series Gastight™ Syringes: Removable-Needle, RN Termination, 22 Gauge, 2 in. Needle Length
Mid-volume GASTIGHT syringe ideal for dispensing volumes from 100 μL up to 100 mL.
| Quantity | Ea. |
|---|---|
| Min. Temperature (English) | 50°F |
| Max. Temperature (Metric) | 115°C |
| For Use With (Application) | Ideal for manual and automated HPLC injections, commonly used in syringe pumps and other liquid handling instruments |
| Max. Pressure | 200 psi |
| Diameter (Metric) Inner Needle | 0.41 mm |
| Product Type | Gastight Syringe |
| Connection Type | Removable |
| Max. Temperature (English) | 239°F |
| Diameter (Metric) Outer Needle | 0.72 mm |
| Length (English) Needle | 2 in. |
| Autoclavable | Autoclavable |
| Needle Gauge | 22 G |
| Diameter (English) Outer Needle | 0.028 in. |
| Diameter (English) Inner Needle | 0.016 in. |
| Connection Type | Fixed |
|---|
Hamilton™ Microliter™ Syringe, 10 μL, Sold by MilliporeSigma™ Supelco™
For use with Agilent/HP 7673 and 7683 Autosamplers
| Volume (Metric) | 10 μL |
|---|---|
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger),Stainless Steel (Tip) |
| Max. Temperature (Metric) | 50°C |
| Length (Metric) Needle | 43 mm |
| Max. Pressure | 2000 psig (137.9 bar) |
| For Use With (Equipment) | Agilent/HP 7673 and 7683 Autosamplers |
| Product Type | Microliter™ Syringe |
| Connection Type | Cemented |
| Max. Temperature (English) | 122°F |
| Length (English) Needle | 1.71 in. |
| Autoclavable | Not Autoclavable |
| Min. Temperature (Metric) | 10°C |
| Product Line | Hamilton |
Hamilton™ Gastight™ Syringe, 10 μL, Sold by MilliporeSigma™ Supelco™
For use with Agilent GC Autosamplers 7693A, 7673, 7683, and 6850 ALS
| Needle Point Number | 1 |
|---|---|
| For Use With (Equipment) | Agilent 7673, 7683, 7693A and 6850 Autosamplers |
| Product Type | Gastight™ Syringe |
| Volume (Metric) | 10 μL |
| Needle Point Style | Cone |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),PTFE (Plunger),Stainless Steel (Tip) |
| Length (English) Needle | 1.71 in. |
| Length (Metric) Needle | 43 mm |
| Min. Temperature (Metric) | 10°C |
| Max. Pressure | 1000 psig (68.9 bar) |
| Product Line | Hamilton |
MilliporeSigma™ Supelco™ Needle Cleaning Kit
Formulated specifically for GC syringes. Perfect for cleaning small orifices such as FID jets and syringe needles.
Hamilton™ 700 Series Syringe, Knurled Hub (KH), Sold by MilliporeSigma™ Supelco™
Gas-tight design minimizes the gas exchange in GC analysis. Syringes provide accurate volume delivery with a plunger that is mostly unsurpassed. A knurled hub is used to make a leak-tight seal between the barrel and needle.
| Description | Sample Contained in Needle (No Dead Volume) |
|---|---|
| Quantity | 1 Ea. |
| Min. Temperature (English) | 50°F |
| Max. Temperature (Metric) | 115°C |
| Length (Metric) Needle | 70 mm |
| Max. Pressure | 6000 psig (413.7 bar) |
| Product Type | Microliter™ Syringe |
| Connection Type | Knurled Hub |
| Max. Temperature (English) | 239°F |
| Diameter (English) Outer | 0.308 in. |
| Length (English) Needle | 2.75 in. |
| Autoclavable | Autoclavable |
| Min. Temperature (Metric) | 10°C |
| Product Line | Hamilton |