Thin, precut membrane rounds for high-throughput, fast filtration of liquid and gas samples. Gridded and non-gridded discs. Various materials including mixed cellulose ester, polycarbonate, PTFE, nylon, and PVDF. For air monitoring/analytical research.
Sizes
Filter membranes are made in a range of diameters, typically designed to fit a specific holder or manifold.
Materials
Filter membrane can be made from cellulose, mixed cellulose esters (MCE), polyvinylidene fluoride (PVDF), polyethersulfone (PES), polyvinyl chloride (PVC), polytetrafluoroethylene (PTFE), nylon, polycarbonate (PC), polyester, polyethylene terephthalate (PET), and polypropylene (PP). Other membrane materials include aluminum oxide, gelatin, porcelain, and glass.
Pore Size
The size of membrane pores determines which particles will be retained by the filter. A pore size of 0.2 µm is small enough to remove microbes from solutions; a 0.45 µm ore size can remove larger particulates.
Color and Grids
White membrane filters may be plain or marked with square grids (outlined in black) that can help with enumerating particles. Gridded or plain black membrane filters may be helpful when filtering light-colored particulates.
Sterility
Filter membranes may be pre-sterilized or may be sterilized using ethylene oxide, gamma irradiation, or autoclaves. The need for sterility is determined by the application, which are many and varied:
- Light microscopy samples
- Cytology sample preparation
- Electron microscopy samples
- Air quality and other environmental monitoring
- Water analysis and water quality testing
- Microbiology colony counting and quality control
- Chemotaxis
- Sterile preparation of buffers, tissue culture media, microbiological media, and other biological fluids
- (11)
- (1)
- (5)
- (99)
- (8)
- (150)
- (9)
- (1)
- (8)
- (4)
- (6)
- (194)
- (1)
- (3)
- (22)
- (76)
- (185)
- (51)
- (126)
- (1)
- (1)
- (46)
- (14)
- (95)
- (18)
- (2)
- (22)
- (26)
- (6)
- (1)
- (4)
- (3)
- (4)
- (4)
- (11)
- (18)
- (8)
- (55)
- (145)
- (62)
- (3)
- (40)
- (225)
- (46)
- (18)
- (28)
- (8)
- (111)
- (31)
- (20)
- (55)
- (1)
- (32)
- (2)
- (13)
- (4)
- (1)
- (16)
- (1)
- (6)
- (25)
- (28)
- (1)
- (1)
- (2)
- (80)
- (5)
- (1)
- (1)
- (36)
- (1)
- (1)
- (810)
- (146)
- (1)
- (1)
- (3)
- (1)
- (3)
- (1)
- (389)
- (309)
- (6)
- (3)
- (134)
- (633)
- (59)
Filtered Search Results
Cytiva Whatman™ Nuclepore™ Hydrophilic Membrane
A highly defined pore size cutoff in the sub-micron range enables particle deformity measurements, and the capture of extremely small particles
| Type | Track Etched Hydrophilic Membrane Filters |
|---|---|
| Shape | Circle |
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | Bioassays, Cell Biology and Environment Analysis |
| Membrane Type | Polycarbonate Film Track-Etched (PFTE) |
Cytiva Whatman™ 1.2μm Pore Size (ME 28) Mixed Cellulose Ester Membranes
Cytiva Whatman 1.2um Pore Size (ME 28) Mixed Cellulose Ester Membranes, Diameter Filter: 47mm, Pore Size: 0.2um
| Pore Size | 1.2 μm |
|---|
MilliporeSigma™ Isopore™ Membrane Filters, 0.6 μm
Use for analyses of airborne contaminants and other particles using optical or electron microscopy. Isopore™ Polycarbonate Membrane Filters have a smooth, glass-like surface for clearer sample observation. Available in a variety of pore sizes/flow rates, diameters and colors.
| Pore Size | 0.6 μm |
|---|---|
| Color | White |
| No. per Case | 100Pack |
| Quantity | 100/Pk. |
| Material | Polycarbonate |
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | Air Analysis; Cell Biology; Cell Culture; Bioassays; Cytology; Environmental Analysis; Epifluorescence. |
| Sterility | Non-sterile |
| Bubble Point | 8.5 psi |
| Flow Rate | Avg. 43 mL/min x cm2 (typical results (at 10 psi);62 mL/min x cm2/psi) |
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Filter Type | Screen Filter |
| Autoclavable | Not Autoclavable |
| Gas Flow Rate | 10.0 L/min/cm2 |
Sartorius Gridded Nonsterile Cellulose Nitrate Membrane Filters: 1.2μm Pore Size
The non-sterile membrane filters are made of cellulose nitrate (cellulose mixed ester), cellulose acetate or regenerated cellulose. They can be used for colony counting, particle testing and microscopy. Choose between gridded or non-gridded, membranes, either with or without hydrophobic edge.
| Pore Size | 1.2 μm |
|---|---|
| Disposable | Single-use |
| Type | Membrane Filter |
| Format | Disc |
| Material (Membrane) | Cellulose Nitrate |
| Color | White |
| Grid Color | Black |
| Quantity | 100/Pk. |
| Material | Cellulose Nitrate |
| Filter Type | Membrane Filter |
| For Use With (Application) | For colony count; sterility testing; particle count; microscopy |
| Sterility | Non-sterile |
Sartorius Microsart™ @Filter 250 in Trays
Membrane filters suitable for use in the Microsart @Filter units
| Disposable | Single-use |
|---|---|
| Type | Filter Tip |
| Format | Disc |
| Diameter (Metric) | 47 mm |
| Material (Membrane) | Cellulose Nitrate |
| Sample Volume | 250 mL |
| Material | Cellulose Nitrate |
| Sterility | Sterile |
Sartorius Microsart™ @Filter 100 in Bags
Membrane filters suitable for use in the Microsart @Filter units
| Disposable | Single-use |
|---|---|
| Format | Disc |
| Diameter (Metric) | 47 mm |
| Sample Volume | 100 ml |
| Material | Cellulose Nitrate |
| Sterility | Sterile |
MilliporeSigma™ Omnipore™ Membrane Filters, 0.45 μm
Hydrophilic PTFE polymer membrane filter compatible with virtually all solvents, acids, and alkaline solutions. Omnipore™ Membrane Filters are biologically and chemically inert.
MilliporeSigma™ PVC Membrane Filters, 5 μm
For air monitoring applications to analyze silica, carbon black or quartz particulates
3M Zeta Plus™ LP Series Filter Media Disc
Filter media is composed of inorganic filter aid cationic resin and is designed to be very low in extractables. This LP media is completely free of asbestos and glass microfibre.
| Disposable | Single-use |
|---|---|
| Type | Filtration Disc |
| Format | Disc |
| Length (English) | 11.5 in. |
| Quantity | 100/Cs. |
| Material | Cellulose |
| Sterility | Non-sterile |
Sartorius Cellulose Nitrate Membrane Filter
Cellulose nitrate membrane filters with 293 mm diameters are hydrophilic, have high flow rates thanks to their symmetrical structure and are compatible with aqueous solutions, hydrocarbons and several other organic solvents.
| Disposable | Single-use |
|---|---|
| Type | Membrane Filter |
| Format | Disc |
| Diameter (Metric) | 293 mm |
| Quantity | 100/Cs. |
| Material | Cellulose Nitrate |
| Filter Type | Membrane Filter |
| Sterility | Non-sterile |
Sartorius Cellulose Acetate Membrane Filter
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Cellulose acetate membrane filters with 142 mm diameter combine thermal stability with exceptionally low adsorption characteristics.
| Disposable | Single-use |
|---|---|
| Type | Membrane Filter |
| Format | Disc |
| Diameter (Metric) | 142 mm |
| Quantity | 25/Cs. |
| Material | Cellulose Acetate |
| Filter Type | Membrane Filter |
| Sterility | Non-sterile |
Cytiva Whatman™ 0.8 μm Pore Size (ME 27) Mixed Cellulose Ester Membranes, White/Black Grid
Whatman™ (ME 27) Mixed Cellulose Ester Membranes, White/Black Grid are particularly effective in applications requiring higher flow rates and larger volume filtration. Supplied with clearly defined grid lines at regularly spaced intervals to assist in microbiological colony counting.
| Pore Size | 0.8 μm |
|---|---|
| Diameter (English) | 1.85 in. |
| Material (Membrane) | ME 27 |
| Color | White |
| Grid Color | Black |
| Quantity | 100 Pk. |
| Material | MCE |
| For Use With (Application) | Filtration, cytology, air monitoring, aqueous HPLC samples, biological assays |
| Sterility | Sterile |
| Thickness (Metric) | 140 μm |
| Bubble Point | 1.3 bar |
| Flow Rate | 2.8 sec./100 mL/12.5 cm2 (at Δp = 0.9 bar) |
| Diameter (Metric) | 47 mm |
| Thickness (English) | 0.006 in. |
| Autoclavable | Autoclavable |
| Size (Metric) Grid | 3.1 mm |
| Gas Flow Rate | 11.6 sec./100 mL (at Δp = 3 mbar) |
MilliporeSigma™ Fluoropore™ Membrane Filters, 0.5 μm
Hydrophobic membrane with laminated backing for easier handling
| Pore Size | 0.45 μm |
|---|---|
| Bubble Point | 7 psi |
| Flow Rate | 60 mL/min x cm2 |
| Wettability | Hydrophobic |
| Type | Filter Membranes |
| Color | White |
| Material | PTFE |
| Hydrophobicity | Hydrophobic |
| For Use With (Application) | Clarification of Acids, Bases and Solvents; Clarification of Alcohol Solutions; UV Spectroscopy. |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
| Gas Flow Rate | 8.0 L/min/cm2 |
MilliporeSigma™ Isopore™ Membrane Filters, 2 μm
Use for analyses of airborne contaminants and other particles using optical or electron microscopy. Isopore™ Polycarbonate Membrane Filters have a smooth, glass-like surface for clearer sample observation. Available in a variety of por
| Flow Rate | Avg. 180 mL/min x cm2 (typical results (at 10 psi);932 mL/min x cm2/psi) |
|---|---|
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Color | White |
| No. per Case | 100Pack |
| Quantity | 100/Pk. |
| Material | Polycarbonate |
| Filter Type | Screen Filter |
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | Air Analysis; Cell Biology; Cell Culture; Bioassays; Cytology; Environmental Analysis; Epifluorescence. |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |