Filtration Membrane Discs
Thin, precut membrane rounds for high-throughput, fast filtration of liquid and gas samples. Gridded and non-gridded discs. Various materials including mixed cellulose ester, polycarbonate, PTFE, nylon, and PVDF. For air monitoring/analytical research.
Sizes
Filter membranes are made in a range of diameters, typically designed to fit a specific holder or manifold.
Materials
Filter membrane can be made from cellulose, mixed cellulose esters (MCE), polyvinylidene fluoride (PVDF), polyethersulfone (PES), polyvinyl chloride (PVC), polytetrafluoroethylene (PTFE), nylon, polycarbonate (PC), polyester, polyethylene terephthalate (PET), and polypropylene (PP). Other membrane materials include aluminum oxide, gelatin, porcelain, and glass.
Pore Size
The size of membrane pores determines which particles will be retained by the filter. A pore size of 0.2 µm is small enough to remove microbes from solutions; a 0.45 µm ore size can remove larger particulates.
Color and Grids
White membrane filters may be plain or marked with square grids (outlined in black) that can help with enumerating particles. Gridded or plain black membrane filters may be helpful when filtering light-colored particulates.
Sterility
Filter membranes may be pre-sterilized or may be sterilized using ethylene oxide, gamma irradiation, or autoclaves. The need for sterility is determined by the application, which are many and varied:
- Light microscopy samples
- Cytology sample preparation
- Electron microscopy samples
- Air quality and other environmental monitoring
- Water analysis and water quality testing
- Microbiology colony counting and quality control
- Chemotaxis
- Sterile preparation of buffers, tissue culture media, microbiological media, and other biological fluids
- (11)
- (1)
- (5)
- (99)
- (8)
- (150)
- (9)
- (1)
- (8)
- (4)
- (6)
- (194)
- (1)
- (3)
- (22)
- (78)
- (185)
- (51)
- (126)
- (1)
- (1)
- (46)
- (14)
- (95)
- (18)
- (2)
- (22)
- (26)
- (6)
- (1)
- (4)
- (3)
- (4)
- (4)
- (11)
- (18)
- (8)
- (55)
- (145)
- (62)
- (3)
- (40)
- (225)
- (46)
- (18)
- (28)
- (8)
- (111)
- (31)
- (20)
- (55)
- (1)
- (32)
- (2)
- (13)
- (4)
- (1)
- (1)
- (16)
- (1)
- (6)
- (25)
- (28)
- (1)
- (1)
- (2)
- (80)
- (5)
- (1)
- (1)
- (1)
- (36)
- (1)
- (1)
- (810)
- (146)
- (1)
- (1)
- (3)
- (1)
- (3)
- (1)
- (389)
- (309)
- (6)
- (2)
- (3)
- (134)
- (633)
- (59)
Filtered Search Results
Cytiva Whatman™ 0.6 μm Pore Size (ME 26) Mixed Cellulose Ester Membranes, Plain
Whatman™ (ME 26) Mixed Cellulose Ester Membranes are particularly effective in applications requiring higher flow rates and larger volume filtration, including clarification or sterilization of aqueous solutions, particulate analysis and removal, air monitoring, and microbial analysis.
| Pore Size | 0.6 μm |
|---|---|
| Disposable | Single-use |
| Bubble Point | 3.7 bar |
| Flow Rate | 4.8 sec./100 mL/12.5cm² (at Δp = 0.9 bar) |
| Material (Membrane) | ME 26 |
| Grid Color | Plain |
| Material | MCE |
| Surface Type | Plain |
| For Use With (Application) | Filtration, cytology, air monitoring, aqueous HPLC samples, biological assays |
| Autoclavable | Autoclavable |
| Sterility | Non-sterile |
| Gas Flow Rate | 21 sec./100 mL (at Δp = 3 mbar) |
Cytiva Whatman™ ME 24 Plain Mixed Cellulose Ester Membranes
Enables the uptake of growth media to the bacterial colonies without chemically inhibiting their growth. Whatman™ ME 24 Plain Mixed Cellulose Ester Membranes are composed of cellulose acetate and cellulose nitrate, which provides a more uniform surface.
| Thickness (Metric) | 135 μm |
|---|---|
| Includes | Interleaving paper |
| Pore Size | 0.2 μm |
| Bubble Point | 3.7bar |
| Flow Rate | 20s/100mL/12.5cm2 |
| Grid Color | Plain |
| Material | MCE |
| Autoclavable | Autoclavable |
| Membrane Type | ME24 |
MilliporeSigma™ PVC Membrane Filters, 5 μm
For air monitoring applications to analyze silica, carbon black or quartz particulates
| Thickness (Metric) | 190 μm |
|---|---|
| Pore Size | 1.2 μm |
| Bubble Point | ≥0.4 bar, air with water |
| Flow Rate | Avg. 175 mL/min x cm2 (typical results @ 10 psi);687 mL/min x cm2/psi |
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Color | White |
| Material | Nylon |
| Filter Type | Screen Filter |
| No. per Pack | 100Pack. |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
Sartorius Gridded Nonsterile Cellulose Nitrate Membrane Filters: 0.45μm Pore Size
The Nonsterile Membrane Filters are made of cellulose nitrate (cellulose mixed ester), cellulose acetate or regenerated cellulose. They can be used for colony counting, particle testing and microscopy. Choose between gridded or non-gridded, membranes, either with or without hydrophobic edge.
| Pore Size | 0.45 μm |
|---|---|
| Disposable | Single-use |
| Type | Membrane Filter |
| Format | Disc |
| Material (Membrane) | Cellulose Nitrate |
| Material | Cellulose Nitrate |
| Filter Type | Membrane Filter |
| For Use With (Application) | For Colony Count, Sterility Testing, Particle Count, Microscopy |
| Sterility | Non-sterile |
Sartorius Polyamide (Nylon) Membrane Filters
Recommended for particle-removing filtration of water, aqueous solutions and solvents for analytical determination. Sartorius Polyamide (Nylon) Membrane Filters are white, non-sterile filters without grids. Choose from two pore sizes in four diameters. Bulk packed for space and cost savings.
| Thickness (Metric) | 115 μm |
|---|---|
| Disposable | Single-use |
| Type | Membrane Filter |
| Format | Disc |
| Color | White |
| Material | Polyamide |
| Filter Type | Membrane Filter |
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | Recommended for particle removing filtration of water; aqueous solutions and solvents for analytical determination. |
| Autoclavable | Autoclavable |
| Sterility | Non-sterile |
Cytiva Whatman™ 1.2μm Pore Size (ME 28) Mixed Cellulose Ester Membranes
Cytiva Whatman 1.2um Pore Size (ME 28) Mixed Cellulose Ester Membranes, Diameter Filter: 47mm, Pore Size: 0.2um
| Pore Size | 1.2 μm |
|---|
Cytiva Whatman™ Polyamide Membranes
Universal filter made from pure polyamide for clarification and sterile filtration
| Thickness (Metric) | 110 μm |
|---|---|
| Material | Polyamide |
| Hydrophobicity | Hydrophilic |
Cytiva Whatman™ Cyclopore PC Polycarbonate Membrane Filters
Microporous membranes featuring sharp cut-off and reproducible lab microfiltration characteristics of track-etched membrane filters
| Type | Membrane filters |
|---|---|
| Temperature (English) Operating | 284 °F |
| Pore Density | Min: 105 pores/cm2, Max: 6 x 108 pores/cm2 |
| Quantity | 100 Pk. |
| Material | Polycarbonate |
| Porosity | Min: 4%, Max: 20% |
| Temperature (Metric) Operating | 140 °C |
| For Use With (Application) | For general filtration, Cross-flow filtration, Air and water monitoring, Microorganism analysis, Healthcare applications, Immunodiagnostics |
| Autoclavable | Autoclavable |
Sartorius Hydrophobic edged Sterile Cellulose Nitrate and Acetate Membrane Filters
Membrane Filters for Colony Counting and Sterility Testing - Cellulose nitrate (cellulose ester), Cellulose acetate and regenerated Cellulose, hydrophobic edged, individually, sterile packaged
| Disposable | Single-use |
|---|---|
| Type | Membrane Filter |
| Format | Disc |
| Color | White |
| Grid Color | Black |
| Quantity | 100/Pk. |
| Filter Type | Membrane Filter |
| Hydrophobicity | Hydrophobic |
| Sterility | Sterile |
Cytiva Whatman™ 90 mm Nuclepore™ Polycarbonate Track-Etched Membranes
Manufactured from high-quality polycarbonate film and track-etched for high pore size precision. Whatman™ Polycarbonate Hydrophilic Membranes combine high flow rates and chemical and thermal resistance with sharply defined pores, making them suitable for microscopy, cytology, parasitology, and certain air and oceanography analyses.
| Flow Rate | High |
|---|---|
| Diameter (Metric) | 90 mm |
| Material | Nucleopore Polycarbonate |
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | Epifluorescence microscopy, environmental analysis, cell biology |
Cytiva Whatman™ Sterile Mixed Cellulose Ester Gridded Membranes
Composed of cellulose acetate and cellulose nitrate.
Sartorius Microsart™ @Filter 250 in Bags
Membrane filters suitable for use in the Microsart @Filter units
| Disposable | Single-use |
|---|---|
| Type | Filter Tip |
| Format | Disc |
| Diameter (Metric) | 47 mm |
| Material (Membrane) | Cellulose Nitrate |
| Sample Volume | 250 mL |
| Material | Cellulose Nitrate |
| Sterility | Sterile |