General Spectrometer Accessories
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (5)
- (5)
- (5)
- (1)
- (14)
- (1)
- (2)
- (4)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (10)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (3)
Filtered Search Results
Glass Expansion Contour Flared End PVC Pump Tube 2tag, 152mm spacing, 0.44mm ID, Green/Yellow (PKT 6)
Contour Flared End PVC Pump Tube 2tag 0.44mm ID Green/Yellow (PKT 6).Tag Colors: Green/YellowID mm: 0.44Wall Thickness mm: 0.91OD mm: 2.26Overall Length: 455mm (152mm spacing between tags)Number of Tubes Per Pack: 6Physical Properties: Thermoplastic, PVC based material with plasticizerMaterial: Made from Tygon R3603/R3607 or equivalent.Special Properties: Inexpensive all-around tubing for general laboratory applicationsChemical Compatibility: Excellent for aqueous solutions of the following acids and concentrations, up to 35% Nitric Acid, up to 37% Hydrochloric Acid, up to 25% Hydrofluoric Acid, up to 30% Hydrogen Peroxide.Limitations: Potential leaching of plasticizersGlass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Nickel Skimmer Cone for PerkinElmer NexION 300/350/1000/2000 ICP-MS (W1026356)
Nickel Skimmer Cone (W1026356) ¿ Standard skimmer cone for PerkinElmer NexION 1000/2000/300/350 ICP-MS. Suitable for most common applications (e.g., routine aqueous samples, <5% acid matrix, non-HF, non-organic). Not recommended for samples containing HF. Use 10x Magnifier Inspection Tool with Built-In LED Illumination (NC2042261) to inspect cone orifice condition. When not in use, keep cones stored in original packaging for protection. Use skimmer ConeGuard to protect cone threads during cleaning, 70-803-1026.For corrosive samples, including HF, we recommend Platinum Skimmer Cones, see catalog number 501907688.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Nickel Skimmer Cone for x-lens Agilent 7900/8900 ICP-MS (G8400-67200)
Nickel Skimmer Cone for x-lens (G8400-67200) ¿ For Agilent 7900/8900 ICP-MS. Standard cone used with x-lens and suitable for most common applications (e.g., routine aqueous environmental samples, <5% acid matrix, non-HF, non-organic). Not for samples containing hydrofluoric acid (HF). Use 10x Magnifier Inspection Tool with Built-In LED Illumination (NC2042261) to inspect cone orifice condition. Use Skimmer ConeGuard (70-803-1004) to protect cone threads during cleaning. When not in use, keep cones stored in original packaging for protection.For corrosive acids, including HF, use Pt Skimmer with Cu Base for x-lens, P/N 501907594, must be mounted on brass adaptor skimmer base. For organic analysis, use Pt Skimmer with Ni Base for x-lens, P/N 501907595, which must be mounted on brass adaptor skimmer base.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Tracey Spray Chamber with Helix CT, 50ml cyclonic, Borosilicate glass. Includes UFT-16-75 and UFT-2-700 UniFit Connectors (1 each), and 70-803-1439 Helix CT locking screw with seal (1 unit)
Tracey spray chamber, includes Helix CT locking screw & seal (1 pc), UniFit with 1.6mm (1/16") OD x 0.75mm ID x 700mm long tube, & 13mm ball joint clip (1ea). Made from borosilicate glass, 50mL volume. Compatible with Agilent 5000 Series, Agilent MP-AES, PE Avio 200/500 & Spectro Genesis.The Tracey is a cyclonic design providing the highest sensitivity and fastest washout performance for ICP analyses. Ideal choice for most ICP applications, especially for those requiring the highest sample throughput and performance.The unique Helix CT interface consists of two parts, a ConstantTorque Locking Screw & chemically inert PressFit ferrule. The main feature of the Helix CT is the built-in, ratcheting torque control mechanism that allows for a consistent, zero dead volume, inert seal of the nebulizer.Replacement parts include NC1943061 & NC2081825, suggested to replace every 6 months.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Nickel Sampler Cone with Nickel Plated Base for Agilent 7700/7800/7850/7900/8800/8900 ICP-MS (G3280-67061)
Nickel Sampler Cone with Nickel Plated Base (G3280-67061) ¿ For Agilent 7700/7800/7850/7900/8800/8900 ICP-MS. For samples with >0.5% HCL or when using maximum HMI dilution. Not for samples containing hydrofluoric acid (HF). Use 10x Magnifier Inspection Tool with Built-In LED Illumination (NC2042261) to inspect cone orifice condition. When not in use, keep cones stored in original packaging for protection.For corrosive acids, including HF, use Pt Sampler with Ni Base, P/N 501907586. For high TDS samples causing rapid cone deposition, use Pt Sampler with Ni Base, P/N 501907585. For lowest Ni background & laser ablation applications, use Al Sampler, see AT7701-Al.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Contour Flared End Solva Flex Pump Tube 2tag, 140mm spacing, 0.51mm ID, Orange/Yellow (PKT 6)
Contour Flared End Solva Flex Pump Tube 2tag, 140mm spacing, 0.51mm ID Orange/Yellow (PKT 6).Tag Colors: Orange/YellowID mm: 0.51Wall Thickness mm: 0.91OD mm: 2.33Overall Length: 455mm (140mm spacing between tags)Number of Tubes Per Pack: 6Physical Properties: Thermoplastic, PVC based material with plasticizerMaterial: Made from Tygon 4040 or equivalent.Special Properties: Special tubing for hydrocarbons, petroleum products and distillates.Chemical Compatibility: Ideal for gasoline, kerosene, heating oils, cutting liquids and coolants based on glycols.Limitations: Not recommended for strong acids and alkalis, foodstuffs, beverages and medicines. Potential leaching of plasticizersGlass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Contour Flared End PVC Pump Tube 3tag, 72mm spacing, 0.76mm ID, Black/Black (PKT 6)
Contour Flared End PVC Pump Tube 3tag 0.76mm ID Black/Black (PKT 6).Tag Colors: Black/BlackID mm: 0.76Wall Thickness mm: 0.86OD mm 2.48Overall Length: 455mm (72mm spacing between tags)Number of Tubes Per Pack: 6Physical Properties: Thermoplastic, PVC based material with plasticizerMaterial: Made from Tygon R3603/R3607 or equivalent.Special Properties: Inexpensive all-around tubing for general laboratory applicationsChemical Compatibility: Excellent for aqueous solutions of the following acids and concentrations, up to 35% Nitric Acid, up to 37% Hydrochloric Acid, up to 25% Hydrofluoric Acid, up to 30% Hydrogen Peroxide.Limitations: Potential leaching of plasticizersGlass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Long Life Shield Plate for Agilent 7500/7700/7800/7850/7900/8800/8900 (G1833-65419)
Long Life Shield Plate (G1833-65419) - For Agilent 7500/7700/7800/7850/7900/8800/8900.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Nickel Skimmer Cone for Thermo Scientific Element 1/Element 2/Neptune/Neoma ICP-MS (1067600)
Nickel Skimmer Cone (1067600) ¿ Suitable for Thermo/Finnigan Neoma MC-ICP-MS, Element 1, 2 & Neptune. For lowest copper backgrounds. Not recommended for samples containing hydrofluoric acid (HF). Use 10x Magnifier Inspection Tool with Built-In LED Illumination (NC2042261) to inspect cone orifice condition. When not in use, keep cones stored in original packaging for protection.For lowest boron background, semiconductor applications, and samples containing HF along with other highly corrosive samples where acid concentration begin to exceed 5%, we recommend a platinum cone, see catalog number 501907714.For high sensitivity applications, we recommend 501907707.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Aluminum Hyper Skimmer Cone for PerkinElmer NexION 300/350/1000/1100/2000 (W1033995)
Aluminum Hyper Skimmer Cone (W1033995) ¿ Standard hyper skimmer cone for PerkinElmer NexION 1000/2000/300/350 ICP-MS. Suitable for most common applications (e.g., routine aqueous samples, <5% acid matrix, non-HF, non-organic). Not recommended for samples containing HF. Use 10x Magnifier Inspection Tool with Built-In LED Illumination (NC2042261) to inspect cone orifice condition. When not in use, keep cones stored in original packaging for protection.For corrosive samples, including HF, we recommend Platinum/Nickel Hyper Skimmer Cones, PE3015-Pt/Ni.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Tracey TFE Spray Chamber with Helix CT 50ml cyclonic, PTFE. Includes UFT-16-75 and UFT-2-700 UniFit Connectors (1 each) and 70-803-1439 Helix CT locking screw with seal (1 unit)
Tracey PTFE spray chamber, includes Helix CT locking screw & seal, UniFit 1.6mm OD x 0.75mm ID x 700mm long tube, & UniFit 2.0mm OD x 0.86mm ID x 700mm long tube (1 ea). Made from PTFE, 50mL volume. Compatible with Horiba 24, 38 & 138 Series, Ultima, Activa ICP-OES.The Tracey PTFE is a HF-resistant cyclonic design with a proprietary Stediflow surface treatment that significantly improves sensitivity & precision, in addition to enhancing washout efficiency compared to other inert spray chamber designs. The interior surface can be refurbished at a nominal cost, average lifespan of treatment is 12 months when well cared for.The main feature of the Helix CT interface is the built-in, ratcheting torque control mechanism that allows for a consistent, zero dead volume & chemically inert seal of the nebulizer.Replacement parts include NC1943061, UFT-2-700, NC2081825 & V-044, suggested to replace every 6 months.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion SeaSpray DC Nebulizer 0.4mL/min (N8151070)
SeaSpray DC Nebulizer 0.4 mL/min, includes UniFit Connector with 0.50mm ID x 1.6mm OD x 700mm long tubing (1 piece) and DC Gas Fitting Type 23 with ratchet connector (1 piece). Compatible with PerkinElmer NexION 1000/2000/5000.Optimum nebulizer gas flow rate is 1.0 L/min and sample flow rate is 0.4 mL/min. Recommended not to exceed optimum 0.4 mL/min sample flow rate; however, lower gas and sample flow rates are OK. The backpressure should read approximately 40 psi at 1.0 L/min gas flow rate. Can tolerate up to 20% TDS. We recommend the use of the Elegra Argon Humidifier to achieve best performance with high TDS.Replacement parts include P/Ns 502702959 and 501907305.Recommend nebulizer maintenance tools are Fluka RBS25 (P/N NC9000117) and Eluo Nebulizer Cleaning Tool (P/N NC9462559). When nebulizer is not in use, best to store in the provided hard plastic case.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Twister TFE Spray Chamber with Helix CT, 50ml cyclonic, PTFE. Includes UFT-075 UniFit Connector (1 unit) and 70-803-1439 Helix CT locking screw with seal (1 unit)
Twister PTFE spray chamber, includes Helix CT locking screw & seal (1 pc) & UniFit with 1.3mm OD x 0.75mm ID x 700mm long tube (1 pc). Made from PTFE for HF resistance, 50mL volume. Compatible with Agilent 5000 series and PE Avio 200/500 series ICP-OES.The Twister PTFE is a HF-resistant, baffled cyclonic design with a proprietary Stediflow surface treatment that significantly improves sensitivity & precision, in addition to enhancing washout efficiency compared to other inert spray chamber designs. The PTFE Twister is an excellent choice for high matrix samples with HF. The interior surface can be refurbished at a nominal cost.The main feature of the Helix CT interface is the built-in, ratcheting torque control mechanism that allows for a consistent, zero dead volume & chemically inert seal of the nebulizer.Replacement parts include UFT-075, NC2081825 & V-044, suggested to replace every 6 months.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Graphite Gasket for Agilent 7700/7900/8800/8900 Sampler Cone, PKT 3 (G3280-67009)
Graphite Sampler Cone Gasket, PKT 3 (G3280-67009). For Agilent 7700/7900/8800/8900 ICP-MS. Use a new gasket each time the cone is installed, even if it is the same cone.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Platinum Sampler Cone (Boron-Free) for PerkinElmer NexION 300/350/1000/1100/2000/2200/5000 ICP-MS
Platinum Sampler Cone, Boron-Free ¿ For PerkinElmer NexION 1000/2000/5000/300/350 ICP-MS. Suitable for applications requiring low boron background, including corrosive samples (e.g., routine aqueous environmental samples, >5% acid matrix, HF, organic). Replace Sampler Cone Gasket each time the cone is installed, even if it is the same cone (501907691). Use 10x Magnifier Inspection Tool with Built-In LED Illumination (NC2042261) to inspect cone orifice condition. When not in use, keep cones stored in original packaging for protection. Use Sampler ConeGuard to protect cone threads during cleaning, 70-803-1024.For most common applications (e.g., routine aqueous samples, <5% acid matrix, non-HF, non-organic) we recommend Nickel Sampler Cones, see catalog number 501907684. For corrosive samples use Platinum Sampler Cones, see catalog number 501907686.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More