Slide Mounting Media
- (30)
- (1)
- (1)
- (1)
- (1)
- (4)
- (2)
- (1)
- (1)
- (2)
- (1)
- (23)
- (2)
- (1)
- (1)
- (3)
- (6)
- (1)
- (3)
- (1)
- (2)
- (8)
- (6)
- (1)
- (2)
- (1)
- (17)
- (7)
- (1)
- (1)
- (1)
- (1)
- (4)
- (2)
- (3)
- (3)
- (2)
- (12)
- (1)
- (1)
- (2)
- (1)
- (16)
- (2)
- (21)
- (12)
- (1)
- (2)
- (23)
- (10)
- (2)
Filtered Search Results
BIOHIPPO AAV-hSyn-DIO-mito-EGFP-P2A-tdTomato-WPRE-hGH-polyA
Recombinant adeno associated virus expressing EGFP mito-EGFP tdTomato under the hSyn promoter with WPRE and hGH polyA elements. The Cre dependent configuration enables expression only after recombination, providing precise targeted control of targeted neurons. Offered under the Biohippo AAVX Series with multiple serotypes available including AAV2/1, AAV2/2, AAV2/5, AAV2/6, AAV2/6m, AAV2/6.2FF, AAV2/7m8, AAV2/8, AAV2/9, AAV2/DJ, AAV2/DJ8, AAV2/Retro, AAV2/PHP.eB, AAV2/PHP.B, AAV2/rh10, AAV2/PHP.S, AAV2/anc80, AAV2/B10, AAV2/olig001, AAV2/BI30, AAV2/BR1, AAV2/MG1.2, AAV1/2, AAV2/MaCPNS1, and AAV2/MaCPNS2. Regular titer is greater than or equal to 2.00E+12 vg per mL, with high titer greater than or equal to 1.00E+13 vg per mL available upon request at no additional cost. Customers may specify preferred serotype and titer when placing orders.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences EUKITT Mounting Medium 100 ML
Eukitt is a mounting medium (5% Acrylic Resin and 55% Xylenes) that is used in microscopy. It is an adhesive and specimen preservative that can be used manually and in automated coverslipping equipment. Special purpose adhesive and sealant for use with glass, non plastic and other non-reactive materials. It spreads quickly and evenly withoutforming any air bubbles. It is fast-drying (20 minutes) with a refractive index close to glass. Chemically neutral and has no reaction to staining.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Citifluor™ Mountant Solution AF3, Glycerol Free, Non Hardening 25 ML
Citifluor mounting medium for immunofluorescence is designed to reduce the fading of the fluorescence of dyes used for labeling biological specimens. In the technique of fluorescence microscopy, the fluorescence is stimulated by high intensity UV and/or visible light. Absorption of the light populates an excited state of the dye (usually a singlet state) and this leads to fluorescence. However, the excited state of the dye may undergo chemical reaction, which leads to destruction as evidenced by the fading of the fluorescence and consequent loss of the image. PBS solution containing an amine-based antifadent.
Material: Glycerol Free
Type: Non Hardening
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
AdipoGen DAPI 2HCl Solution 10mM water
Chemical. CAS 28718-90-3. Formula C16H15N5 . 2HCl. MW 350.25. DAPI 4,6-Diamidino-2-phenylindole dihydrochloride is a cell permeable, fluorescent dye that is a minor groove-binding probe for DNA. Binds to the minor groove of double-stranded DNA preferentially to AT rich DNA, forming a stable complex which fluoresces approximately 20 times greater than DAPI alone. DAPI is several times more sensitive than ethidium bromide for staining DNA in agarose gels. It may be used for photofootprinting of DNA, to detect annealed probes in blotting applications by specifically visualizing the double-stranded complex, and to study the changes in DNA and analyze DNA content during apoptosis using flow cytometry. DAPI staining has also been shown to be a sensitive and specific detection method for mycoplasma. Spectral Data Excitation lambdaex 340 nm Emission lambdaem 488 nm only DAPI. Excitation lambdaex 360nm Emission lambdaem 460nm DAPI-DNA complex.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Abcam Anti-Fade Fluorescence Mounting Medium - Aqueous, Fluoroshield
Anti-Fade Fluorescence Mounting Medium - Aqueous, Fluoroshield
The product is subject to the following: Abcam Restricted Use Statement
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences EMS CCC Carbon Adhesive 30 GR
An electrically Carbon Conductive Cement for specimen mounting in all SEM work. After drying of the cement, immediate investigation of conductive specimens is possible. Non-conductive specimens need only to be coated with carbon or metal. Thinner is available if the cement viscosity is too thick.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Fluoro-Gel with Anti-Fading Agent 20 ML
Fluoro-Gel Mounting Medium with a strong anti-fading agent 1,4-phenylenediamine is an aqueous mounting medium for preserving fluorescence of tissue and cell smears. This unique formula preserves rapid photobleaching of FITC, Texas Red, AMCA, Cy2, Cy3, Cy5, Alexa Fluoro 388, Alexa Fluoro 594 tetramethyly rhodamine, and Redox. The fluorescence is retained during prolong storage at 4 degree C in the dark.
This medium contains Phynylenediamine and is not suitable for immunofluorescence of Cy dyes, Phycoerythrin (R-PR) phycocyanin (PC), and allophycocyanin (APC). Prepared from TRIS buffer. Ready-to-use mounting medium with dark coffee color, this is normal, and does not interfere with immuno-fluorescence.
Storage in temperature of 2-8 degree C is recommended. Protect from light. DO NOT FREEZE.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Citifluor™ Mountant Solution AF4, Glycerol Based, Non Hardening 25 ML
Citifluor mounting medium for immunofluorescence is designed to reduce the fading of the fluorescence of dyes used for labeling biological specimens. In the technique of fluorescence microscopy, the fluorescence is stimulated by high intensity UV and/or visible light. Absorption of the light populates an excited state of the dye (usually a singlet state) and this leads to fluorescence. However, the excited state of the dye may undergo chemical reaction, which leads to destruction as evidenced by the fading of the fluorescence and consequent loss of the image. A glycerol solution of n-propyl gallate.
Material: Glycerol Based
Type: Non Hardening
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Fluoro Gel with Dabco 100 ML
Fluoro Gel with antifading agent 1, 4-Diazobicyclo-(2,2,2-octane (DABCO) is an aqueous mounting medium for preserving fluorescence of tissue and cell smears. This unique formula prevents rapid photobleaching of FITC, Texas Red, AMCA, Alexa fluoro 488, Alexa fluoro 594, Cy dyes, tetramethyly rhodamine, and Redox. The fluorescence is retained during prolonged storage at 4 degree C in the dark. Use for immunofluorescence and confocal microscopy. Storage at 2-8 degree C is recommended
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Clear-Mount, (with Tris Buffer), 30 mL
Clear-Mount is a water based mounting medium designed for the permanent mounting of hydrated tissues, which may be damaged with organic solvents. Such samples include cell smears, with peroxidase and alkaline phosphatase chromogens. This mounting medium preserves Fast Red, Aminoethylycarbazole (AEC), NBT/BCIP, INT/BCIP chromogens and is also compatible with counter-stain such as Hematoxylin and Nuclear Fast Red. It is also suitable for chromogens like DAB and DAB with Nickel and Cobalt. It is not compatible with H and E staining. Application: Mounting of Immunohisto slides.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences JB-4™ Embedding Kit 1 GR
A water soluble embedding media which is based on Glycol Methacrylate (GMA) plastic embedding. It is intended for use in preparing samples for high resolution microscopes (HRLM). The catalyzed monomer acts as a dehydration and infiltration agent; therefore, complete dehydration through 100% ethanol is not necessary (although recommended for large or dense tissues). Conventional paraffin sections have a greater degree of shrinkage and produce inadequate morphology when compared to JB-4. Kit includes 800 ml Solution A, 30 ml Solution B, 12 g catalyst.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Research Products International Corp HybriWell Sealing Covers, 21 x 40mm Chamber, 50-100ul Chamber Volume, 100 per Package
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
HybriWell covers seal securely to a microscope slide surface in seconds and can be easily removed after heating. These RNase free, hydrophobic covers eliminate the need for silanizing agents. Access ports allow convenient addition and removal of sample.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Citifluor™ Mountant Solution CFM-3, Glycerol Based, Non Hardening 25 ML
Citifluor mounting medium for immunofluorescence is designed to reduce the fading of the fluorescence of dyes used for labeling biological specimens. In the technique of fluorescence microscopy, the fluorescence is stimulated by high intensity UV and/or visible light. Absorption of the light populates an excited state of the dye (usually a singlet state) and this leads to fluorescence. However, the excited state of the dye may undergo chemical reaction, which leads to destruction as evidenced by the fading of the fluorescence and consequent loss of the image. Glycerol-based antifadent contains a phoenlic antifadent of neutral pH and a refractive index of ~1.52. Acts as a Clearing Solution.
Material: Glycerol Based
Type: Non Hardening
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Abcam Mounting Medium With DAPI - Aqueous, Fluoroshield, 100ML
DAPI mounting medium (previously called Fluoroshield Mounting Medium With DAPI) is an aqueous anti-fade mounting medium designed to preserve fluorescence when imaging tissues and cell samples. - Cited in over 325 publications - Suitable for immunohistochemistry (IHC), immunocytochemistry/immunofluorescence (ICC/IF) and more - Contains 84% water, 0.0002% 4',6-Diamidino-2-phenylindole dihydrochloride
The product is subject to the following: Abcam Restricted Use Statement
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Sigma Aldrich Fine Chemicals Biosciences Eukitt Quick-Hardening Mounting Medium | 25608-33-7 | MFCD00145620 | 100ml
Eukitt Quick-Hardening Mounting Medium | 25608-33-7 | MFCD00145620 | 100ml
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More