HPLC Columns
- (4)
- (1)
- (20)
- (8)
- (3)
- (5)
- (5)
- (17)
- (6)
- (1)
- (6)
- (2)
- (1)
- (381)
- (1)
- (6)
- (306)
- (12)
- (4)
- (1)
- (3)
- (1)
- (163)
- (203)
- (2,034)
- (2)
- (2)
- (161)
- (1)
- (1)
- (83)
- (30)
- (9)
- (80)
- (3)
- (1,472)
- (6)
- (2)
- (32)
- (303)
- (13)
- (4)
- (437)
- (16)
- (2,197)
- (2)
- (1)
- (1)
- (1)
- (7)
- (1)
- (179)
- (7)
- (84)
- (2)
- (9)
- (4)
- (38)
- (9)
- (116)
- (25)
- (1)
- (1)
- (9)
- (10)
- (11)
- (5)
- (323)
- (228)
- (1)
- (1,400)
- (3)
- (7)
- (1)
- (1)
- (143)
- (469)
- (1,533)
- (1)
- (55)
- (1)
- (165)
- (53)
- (1)
- (350)
- (25)
- (988)
- (114)
- (1)
- (21)
- (101)
- (1)
- (483)
- (28)
- (2)
- (3)
- (10)
- (4)
- (2)
- (10)
- (17)
- (2)
- (248)
- (56)
- (1)
- (1,287)
- (16)
- (1)
- (12)
- (15)
- (2)
- (3)
- (130)
- (1)
- (200)
- (4)
- (16)
- (2)
- (3)
- (5)
- (363)
- (14)
- (6)
- (163)
- (10)
- (5)
- (89)
- (614)
- (25)
- (2)
- (43)
- (10)
- (3)
- (14)
- (167)
- (29)
- (15)
- (12)
- (443)
- (138)
- (464)
- (62)
- (8)
- (1,197)
- (30)
- (514)
- (15)
- (2)
- (96)
- (24)
- (3,707)
- (3)
- (10)
- (34)
- (2)
- (25)
- (3)
- (21)
- (30)
- (4)
- (5)
- (4)
- (1)
- (1)
- (4)
- (2,166)
- (1)
- (2)
- (10)
- (482)
- (1)
- (2)
- (20)
- (1)
- (670)
- (258)
- (1,481)
- (1)
- (4)
- (21)
- (3)
- (147)
- (245)
- (5)
- (144)
- (3)
- (13)
- (136)
- (441)
- (49)
- (124)
- (6)
- (75)
- (54)
- (3)
- (67)
- (5)
- (294)
- (2)
- (30)
- (18)
- (34)
- (9)
- (5)
- (3)
- (110)
- (3)
- (2)
- (1)
- (1)
- (5)
- (172)
- (1)
- (1)
- (629)
- (1)
- (8)
- (22)
- (90)
- (6)
- (11)
- (10)
- (2)
- (56)
- (31)
- (21)
- (413)
- (41)
- (156)
- (34)
- (24)
- (129)
- (12)
- (2)
- (2)
- (13)
- (179)
- (114)
- (11)
- (1)
- (313)
- (2)
- (8)
- (7)
- (3,787)
- (124)
- (14)
- (3)
- (1)
- (10)
- (7)
- (4)
- (36)
- (1)
- (83)
- (31)
- (2)
- (11)
- (5)
- (163)
- (1)
- (6)
- (9)
- (1)
- (9)
Filtered Search Results
Thermo Scientific™ BioBasic™ 8 HPLC Columns
Use this column for reversed-phase separation of proteins and other biomolecules.
| Pore Size | 300 Å |
|---|---|
| Particle Size | 5 μm |
| Carbon Load | 5% |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| pH | 2 to 9 |
| Surface Area | 100 m²/g |
| Max. Pressure | 5800 psi (400 bar) |
| Product Line | BioBasic |
| USP Type | L7 |
MilliporeSigma™ Supelco™ Ascentis™ Express C18 UHPLC Column, 2 μm Particle Size
Ascentis™ Express HPLC columns, through the use of Fused-Core™ particle technology, can provide you with both the high speed and high efficiencies of sub-2 μm particles while maintaining lower back pressures.
| Pore Size | 90 Å |
|---|---|
| Particle Size | 2 μm |
| Stationary Phase | C18 (octadecyl) |
| Phase | Reversed Phase |
| Matrix | C18 (octadecyl) Phase/Fused-Core Particle Platform |
| Endcapped | Yes |
| pH | 2 to 9 |
| Technique | Fused-Core UHPLC |
| Product Line | Ascentis |
MilliporeSigma™ Supelco™ Astec™ CHIROBIOTIC™ T2 Chiral HPLC Column, 5 μm Particle Size
CHIROBIOTIC™ T2 utilizes teicoplanin as a chiral selector.
| Pore Size | 200 Å |
|---|---|
| Particle Size | 5 μm |
| Stationary Phase | Teicoplanin Glycopeptide |
| Phase | Chiral |
| Matrix | Teicoplanin Glycopeptide Phase/High-Purity Silica Gel Particle Platform |
| pH | 3.8 to 6.8 |
| Technique | Chiral HPLC |
| Product Line | Astec CHIROBIOTIC |
MilliporeSigma™ Supelco™ Astec™ CHIROBIOTIC™ R Chiral HPLC Column, 5 μm Particle Size
CHIROBIOTIC™ R, based on the ristocetin A glycopeptide covalently bonded to high purity silica particles, has shown particular applicability to enantiomers of anionic compounds.
| Pore Size | 100 Å |
|---|---|
| Particle Size | 5 μm |
| Stationary Phase | Ristocetin A Glycopeptide |
| Phase | Chiral |
| Matrix | Ristocetin A Glycopeptide Phase/High-Purity Silica Gel Particle Platform |
| pH | 3.5 to 6.8 |
| Technique | Chiral HPLC |
| Product Line | Astec CHIROBIOTIC |
MilliporeSigma™ Supelco™ Astec™ CHIROBIOTIC™ V Chiral HPLC Column, 5 μm Particle Size
Neutral molecules, amides, acids, esters and amines show considerable enantioselectivity on these vancomycin-based CSPs.
| Pore Size | 100 Å |
|---|---|
| Particle Size | 5 μm |
| Stationary Phase | Vancomycin |
| Phase | Chiral |
| Matrix | Vancomycin Phase/High-Purity Silica Gel Particle Platform |
| Technique | Chiral HPLC |
| Product Line | Astec CHIROBIOTIC |
MilliporeSigma™ Chromolith™ WP 300 Protein A HPLC Column
Chromolith™ WP 300 columns allow flow rate flexibility for much higher throughput and more solvent options for optimum selectivity.
| Pore Size | Monolith |
|---|---|
| Stationary Phase | Protein A bonding phase |
| Temperature | 2 to 45°C |
| Phase | Affinity Separation |
| Matrix | Monolithic silica |
| Length (Metric) | 25 mm |
| Endcapped | No |
| pH | 1.5 to 7.5 |
| Material | PEEK |
| Technique | HPLC, LC/MS |
| Surface Area | 120 m2/g |
| Max. Pressure | 200 bar |
Thermo Scientific™ POROS™ G 20 μm Protein G Affinty HPLC Columns
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Thermo Scientific™ POROS™ Protein G is based on an immobilized recombinant Protein G functional group designed for high throughput purification of antibodies.
| Particle Size | 20 μm |
|---|---|
| Stationary Phase | Recombinant Protein G |
| Binding Capacity | 9 mg/mL |
| Column Type | Affinity |
| Material | PEEK |
| Product Line | POROS |
| Pore Size | 100 Å |
|---|---|
| Particle Size | 5 μm |
| Carbon Load | 21% |
| Stationary Phase | C18 |
| Phase | Reversed Phase |
| Product Type | Cartridge |
| Packing Material | Silica |
| Column Type | Reversed Phase |
| pH | 2 to 7.5 |
| Material | Stainless Steel |
| Surface Area | 350 m²/g |
| Max. Pressure | 2175 psi (150 bar) to 2900 psi (200 bar) |
Thermo Scientific™ Hypersil™ ODS (C18) Columns, 10μm Particle Size
Provide an excellent C18 phase for a broad range of applications and a global standard for many existing methods
| Pore Size | 120 Å |
|---|---|
| Particle Size | 10 μm |
| Carbon Load | 10% |
| Stationary Phase | C18 |
| Phase | Reversed Phase |
| Packing Material | Silica |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 170 m²/g |
| USP Type | L1 |
Thermo Scientific™ Acclaim™ Mixed Mode WCX-1 HPLC Columns
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Separate cationic molecules with powerful adjustable selectivity control using this mixed-mode reversed-phase and weak cation-exchange LC column.
| Pore Size | 120 Å |
|---|---|
| Stationary Phase | Hydrophobic Alkyl Chain with a Carboxyl Terminus |
| Temperature | 50°C |
| Phase | Reversed Phase, Ion Exchange, Ion Exclusion, HILIC |
| Endcapped | Proprietary |
| Column Type | Mixed Mode |
| Green Features | FSC |
| Surface Area | 300 m²/g |
| Product Line | Acclaim |
| USP Type | L85 |
Thermo Scientific™ ProSwift™ RP-1S PSDVB Reversed Phase HPLC Column, Monolith, 4.6 mm x 50 mm
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Column Format: Analytical Column; Pore Size: Monolith; Column Phase: Reversed Phase
Thermo Scientific™ NativePac OBE-1 SEC Column for Online Sample Preparation
Perform Native-MS analysis of biomacromolecules with the NativePac OBE-1 SEC Column designed for rapid exchange of non-volatile buffer components with a volatile buffer.
Thermo Scientific™ Accucore™ C30 HPLC Columns
Use this specially designed solid core column for fast, high-resolution separations of hydrophobic, long-chain compounds.
| Pore Size | 150 Å |
|---|---|
| Particle Size | 2.6 μm |
| Carbon Load | 5% |
| Stationary Phase | C30 |
| Temperature | 70°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Packing Material | Ultrapure Silica |
| pH | 2 to 8 |
| Surface Area | 80 m²/g |
| Max. Pressure | 14500 psi (1000 bar) |
| Product Line | Accucore |
| USP Type | L62 |
Thermo Scientific™ DNAPac™ RP Columns
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Get high resolution LC and LC-MS separation of oligonucleotides, including double-stranded (ds) DNA/RNA fragments, using these DNAPac reversed phase columns.
Thermo Scientific™ Accucore™ Vanquish™ C18+ UHPLC Columns, 1.5μm
Use the 1.5μm solid core particles of these columns with the Vanquish UHPLC system for unique high-efficiency, high-resolution analyses.
| Pore Size | 80 Å |
|---|---|
| Particle Size | 1.5 μm |
| Carbon Load | 6.5% |
| Stationary Phase | C18 |
| Temperature | 70°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Diameter (Metric) | 2.1 mm |
| pH | 2 to 9 |
| Surface Area | 110 m²/g |
| USP Type | L1 |