Industrial Hygiene and Environmental Monitoring
Filtered Search Results
Thermo Scientific™ DXT-RAD Extremity Dosimeters and Accessories
Disk dosimeters with novel and permanent individual barcodes feature hot or cold sterilization with fast readout
Thermo Scientific™ RadHalo FM Fixed Spectroscopic Area Monitors
Monitor radiation with high sensitivity and accuracy
| Detector Type | Spectroscopic Detector: 3 x 3 in. NaI |
|---|
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only with Enhanced & Sampling Probes
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Width (English) | 9 in. |
|---|---|
| Response Time | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
| Detection Limits | 0.5 ppm of methane |
| Width (Metric) | 22.9 cm |
| Detector Type | Flame Ionization Detector (FID) |
| Flow Rate | 1 L/min., nominal at sample probe inlet |
| Components Measured | Most Organic and Inorganic Compounds |
| Accuracy | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
| Battery Life | 10 hours at 0°C |
| Voltage | 120 V |
| Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Height (English) | 11.5 in. |
| Height (Metric) | 29.2 cm |
| Warranty | One year from date of shipment |
| Depth (English) | 4 in. |
| Concentration | 0 to 30,000 ppm (methane) |
| Battery Type | Lithium-ion |
| Repeatability | ±2% at 500 ppm of methane |
| Serial Interface | USB |
| Computer Requirements | USB port, Windows XP operating system or higher |
| Depth (Metric) | 10.2 cm |
| Fuel | 99.99% H2 for FID |
| Temperature Range (English) | 14°F to 113°F |
| Frequency | 50/60 Hz |
| Portable Operation Time | Minimum 10 hours |
| Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only with Enhanced Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Width (English) | 9 in. |
|---|---|
| Response Time | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
| Detection Limits | 0.5 ppm of methane |
| Width (Metric) | 22.9 cm |
| Detector Type | Flame Ionization Detector (FID) |
| Flow Rate | 1 L/min., nominal at sample probe inlet |
| Components Measured | Most Organic and Inorganic Compounds |
| Accuracy | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
| Battery Life | 10 hours at 0°C |
| Voltage | 120 V |
| Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Height (English) | 11.5 in. |
| Height (Metric) | 29.2 cm |
| Warranty | One year from date of shipment |
| Depth (English) | 4 in. |
| Concentration | 0 to 30,000 ppm (methane) |
| Battery Type | Lithium-ion |
| Repeatability | ±2% at 500 ppm of methane |
| Serial Interface | USB |
| Computer Requirements | USB port, Windows XP operating system or higher |
| Depth (Metric) | 10.2 cm |
| Fuel | 99.99% H2 for FID |
| Temperature Range (English) | 14°F to 113°F |
| Frequency | 50/60 Hz |
| Portable Operation Time | Minimum 10 hours |
| Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only with Sampling Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Width (English) | 9 in. |
|---|---|
| Response Time | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
| Detection Limits | 0.5 ppm of methane |
| Width (Metric) | 22.9 cm |
| Detector Type | Flame Ionization Detector (FID) |
| Flow Rate | 1 L/min., nominal at sample probe inlet |
| Components Measured | Most Organic and Inorganic Compounds |
| Accuracy | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
| Battery Life | 10 hours at 0°C |
| Voltage | 120 V |
| Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Height (English) | 11.5 in. |
| Height (Metric) | 29.2 cm |
| Warranty | One year from date of shipment |
| Depth (English) | 4 in. |
| Concentration | 0 to 30,000 ppm (methane) |
| Battery Type | Lithium-ion |
| Repeatability | ±2% at 500 ppm of methane |
| Serial Interface | USB |
| Computer Requirements | USB port, Windows XP operating system or higher |
| Depth (Metric) | 10.2 cm |
| Fuel | 99.99% H2 for FID |
| Temperature Range (English) | 14°F to 113°F |
| Frequency | 50/60 Hz |
| Portable Operation Time | Minimum 10 hours |
| Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TruScan G3 Handheld Raman Analyzer
TruScan G3 Handheld Raman Analyzer is a rugged, handheld system for rapid material identification in a pharmaceutical manufacturing environment.
Thermo Scientific™ RadEye™ SPRD-GN Spectroscopic Personal Radiation Detector Kit
RadEye SPRD-GN Spectroscopic Personal Radiation Detector Kit, includes RadEye SPRD-GN, software, Holster, Lutetium test adapter, desktop holder, USB data cable, spare batteries, and rugged storage and carry case.
Thermo Scientific™ RadEye™ SPRD-GN Spectroscopic Personal Radiation Detector
Change the game with unprecedented protection. The Thermo Scientific™ RadEye™ SPRD-GN Spectroscopic Personal Radiation Detector is the first personal radiation detector that can significantly exceed the original ANSI N42.48 2008 standards for
Thermo Scientific™ RadEye™ B20 and B20-ER Multi-Purpose Survey Meters
Quickly characterize mixed surface contamination from gamma radiation, x-ray radiation, alpha radiation and beta radiation with dose rate measurement survey meters.
| Height (Metric) | 13 cm |
|---|---|
| Depth (English) | 2.4 in. |
| Diameter (Metric) Window | 44 mm |
| Length (Metric) | 13 cm |
| Width (English) | 2.8 in. |
| Length (English) | 5.2 in. |
| Width (Metric) | 7 cm |
| Battery Type | 2 AAA |
| Units | cps, cpm. Bq, dpm, dps, Sv/h, rem/h |
| Alarm Types | LED, sound, vibrator |
| Battery Life | >500 hr.s on two AAA batteries |
| Diameter (English) Window | 1.7 in. |
| Dimensions (L x W x H) | 5.2 x 2.8 x 5.2 in. (13 x 7 x 13 cm) |
| Efficiency | 2p Efficiency (ref. to 50 mm diameter without rubber sleeve): Am-241; Co-60: 25%; Sr/Y-90: 36%; C-14: 19% |
| Product Type | Survey Meter |
| Depth (Metric) | 6 mm |
| Weight (English) | 0.7 lb. |
| Radiation Type | Gamma |
| Weight (Metric) | 0.3 kg |
| Height (English) | 5.2 in. |
| Measurement Range | Contamination B-20: 0 - 10 kcps; B20ER: 0 - 500 kcps |
Thermo Scientific™ iPCM12 Installed Personnel Contamination Monitor
Reduce employee downtime and lost productivity with an effective radioactive contamination monitoring system for nuclear facility personnel.
| Height (Metric) | 2220 mm |
|---|---|
| Width (English) | 37 in. |
| Width (Metric) | 940 mm |
| Height (English) | 87.5 in. |
Thermo Scientific™ RIIDEye™ X/M Series Handheld Radiation Isotope Identifiers
Quickly and easily locate and identify radioactive material to respond to potential public health and safety threats with portable, rugged, field-ready devices.
| Detector Type | Gamma detector : 2 x 2 in. NaI Scintillator, 1.5 x 1.5 in. LaBr offered in both models |
|---|---|
| Stability | Continuous with Natural Potassium requiring no periodic source replacement or licensing |
| Battery Life | 8 hrs. |
| Display Type | 320 x 240 high brightness 32000-color 3.5 in. LCD |
| Temperature (English) Operating | -4°F to 122°F |
| Energy Range | 20 keV to 3 MeV |
| Product Type | Handheld Radiation Isotope Identifier |
| Dimensions | 32 x 25 x 15 cm (12.6 x 9.8 x 5.8 in.) with 2 x 2 in. NaI |
| Temperature (Metric) Operating | -20°C to 50°C |
| Radiation Type | Gamma |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID (No Probes)
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Width (English) | 9 in. |
|---|---|
| Response Time | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
| Detection Limits | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
| Width (Metric) | 22.9 cm |
| Detector Type | Dual Configured with FID and PID |
| Flow Rate | 1 L/min., nominal at sample probe inlet |
| Components Measured | Most Organic and Inorganic Compounds |
| Accuracy | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
| Battery Life | 10 hours at 0°C |
| Voltage | 120 V |
| Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Height (English) | 11.5 in. |
| Height (Metric) | 29.2 cm |
| Warranty | One year from date of shipment |
| Depth (English) | 4 in. |
| Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
| Battery Type | Lithium-ion |
| Repeatability | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
| Serial Interface | USB |
| Computer Requirements | USB port, Windows XP operating system or higher |
| Depth (Metric) | 10.2 cm |
| Fuel | 99.99% H2 for FID |
| Temperature Range (English) | 14°F to 113°F |
| Frequency | 50/60 Hz |
| Portable Operation Time | Minimum 10 hours |
| Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID with Enhanced Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Width (English) | 9 in. |
|---|---|
| Response Time | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
| Detection Limits | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
| Width (Metric) | 22.9 cm |
| Detector Type | Dual Configured with FID and PID |
| Flow Rate | 1 L/min., nominal at sample probe inlet |
| Components Measured | Most Organic and Inorganic Compounds |
| Accuracy | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
| Battery Life | 10 hours at 0°C |
| Voltage | 120 V |
| Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Height (English) | 11.5 in. |
| Height (Metric) | 29.2 cm |
| Warranty | One year from date of shipment |
| Depth (English) | 4 in. |
| Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
| Battery Type | Lithium-ion |
| Repeatability | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
| Serial Interface | USB |
| Computer Requirements | USB port, Windows XP operating system or higher |
| Depth (Metric) | 10.2 cm |
| Fuel | 99.99% H2 for FID |
| Temperature Range (English) | 14°F to 113°F |
| Frequency | 50/60 Hz |
| Portable Operation Time | Minimum 10 hours |
| Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID with Sampling Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Width (English) | 9 in. |
|---|---|
| Response Time | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
| Detection Limits | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
| Width (Metric) | 22.9 cm |
| Detector Type | Dual Configured with FID and PID |
| Flow Rate | 1 L/min., nominal at sample probe inlet |
| Components Measured | Most Organic and Inorganic Compounds |
| Accuracy | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
| Battery Life | 10 hours at 0°C |
| Voltage | 120 V |
| Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Height (English) | 11.5 in. |
| Height (Metric) | 29.2 cm |
| Warranty | One year from date of shipment |
| Depth (English) | 4 in. |
| Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
| Battery Type | Lithium-ion |
| Repeatability | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
| Serial Interface | USB |
| Computer Requirements | USB port, Windows XP operating system or higher |
| Depth (Metric) | 10.2 cm |
| Fuel | 99.99% H2 for FID |
| Temperature Range (English) | 14°F to 113°F |
| Frequency | 50/60 Hz |
| Portable Operation Time | Minimum 10 hours |
| Temperature Range (Metric) | -10°C to 45°C |