Gas and Vapor Detection
Filtered Search Results
| Components Measured | Water Vapor |
|---|---|
| Quantity | 10 |
ChemDAQ™ Steri-Trac™ 2+ Peracetic Acid Monitor with Acrylic Stand
Steri-Trac™ 2+ Peracetic Acid Monitor provides real-time PAA detection with visual/audible alarms. Includes an acrylic stand for flexible placement. Ideal for monitoring sterilization areas and ensuring safe working conditions.
StatLab™ SafeTech Vapor Monitor
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Vapor monitoring is important to ensure the safety of employees and comply with OSHA guidelines.
| Type | Single Gas Detector |
|---|---|
| For Use With (Equipment) | Laboratory |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only with Enhanced Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Width (English) | 9 in. |
|---|---|
| Response Time | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
| Detection Limits | 0.5 ppm of methane |
| Width (Metric) | 22.9 cm |
| Detector Type | Flame Ionization Detector (FID) |
| Flow Rate | 1 L/min., nominal at sample probe inlet |
| Components Measured | Most Organic and Inorganic Compounds |
| Accuracy | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
| Battery Life | 10 hours at 0°C |
| Voltage | 120 V |
| Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Height (English) | 11.5 in. |
| Height (Metric) | 29.2 cm |
| Warranty | One year from date of shipment |
| Depth (English) | 4 in. |
| Concentration | 0 to 30,000 ppm (methane) |
| Battery Type | Lithium-ion |
| Repeatability | ±2% at 500 ppm of methane |
| Serial Interface | USB |
| Computer Requirements | USB port, Windows XP operating system or higher |
| Depth (Metric) | 10.2 cm |
| Fuel | 99.99% H2 for FID |
| Temperature Range (English) | 14°F to 113°F |
| Frequency | 50/60 Hz |
| Portable Operation Time | Minimum 10 hours |
| Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID with Sampling Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Width (English) | 9 in. |
|---|---|
| Response Time | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
| Detection Limits | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
| Width (Metric) | 22.9 cm |
| Detector Type | Dual Configured with FID and PID |
| Flow Rate | 1 L/min., nominal at sample probe inlet |
| Components Measured | Most Organic and Inorganic Compounds |
| Accuracy | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
| Battery Life | 10 hours at 0°C |
| Voltage | 120 V |
| Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Height (English) | 11.5 in. |
| Height (Metric) | 29.2 cm |
| Warranty | One year from date of shipment |
| Depth (English) | 4 in. |
| Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
| Battery Type | Lithium-ion |
| Repeatability | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
| Serial Interface | USB |
| Computer Requirements | USB port, Windows XP operating system or higher |
| Depth (Metric) | 10.2 cm |
| Fuel | 99.99% H2 for FID |
| Temperature Range (English) | 14°F to 113°F |
| Frequency | 50/60 Hz |
| Portable Operation Time | Minimum 10 hours |
| Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID (No Probes)
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Width (English) | 9 in. |
|---|---|
| Response Time | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
| Detection Limits | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
| Width (Metric) | 22.9 cm |
| Detector Type | Dual Configured with FID and PID |
| Flow Rate | 1 L/min., nominal at sample probe inlet |
| Components Measured | Most Organic and Inorganic Compounds |
| Accuracy | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
| Battery Life | 10 hours at 0°C |
| Voltage | 120 V |
| Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Height (English) | 11.5 in. |
| Height (Metric) | 29.2 cm |
| Warranty | One year from date of shipment |
| Depth (English) | 4 in. |
| Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
| Battery Type | Lithium-ion |
| Repeatability | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
| Serial Interface | USB |
| Computer Requirements | USB port, Windows XP operating system or higher |
| Depth (Metric) | 10.2 cm |
| Fuel | 99.99% H2 for FID |
| Temperature Range (English) | 14°F to 113°F |
| Frequency | 50/60 Hz |
| Portable Operation Time | Minimum 10 hours |
| Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID with Enhanced Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Width (English) | 9 in. |
|---|---|
| Response Time | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
| Detection Limits | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
| Width (Metric) | 22.9 cm |
| Detector Type | Dual Configured with FID and PID |
| Flow Rate | 1 L/min., nominal at sample probe inlet |
| Components Measured | Most Organic and Inorganic Compounds |
| Accuracy | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
| Battery Life | 10 hours at 0°C |
| Voltage | 120 V |
| Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Height (English) | 11.5 in. |
| Height (Metric) | 29.2 cm |
| Warranty | One year from date of shipment |
| Depth (English) | 4 in. |
| Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
| Battery Type | Lithium-ion |
| Repeatability | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
| Serial Interface | USB |
| Computer Requirements | USB port, Windows XP operating system or higher |
| Depth (Metric) | 10.2 cm |
| Fuel | 99.99% H2 for FID |
| Temperature Range (English) | 14°F to 113°F |
| Frequency | 50/60 Hz |
| Portable Operation Time | Minimum 10 hours |
| Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID with Enhanced & Sampling Probes
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Width (English) | 9 in. |
|---|---|
| Response Time | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
| Detection Limits | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
| Width (Metric) | 22.9 cm |
| Detector Type | Dual Configured with FID and PID |
| Flow Rate | 1 L/min., nominal at sample probe inlet |
| Components Measured | Most Organic and Inorganic Compounds |
| Accuracy | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
| Battery Life | 10 hours at 0°C |
| Voltage | 120 V |
| Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Height (English) | 11.5 in. |
| Height (Metric) | 29.2 cm |
| Warranty | One year from date of shipment |
| Depth (English) | 4 in. |
| Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
| Battery Type | Lithium-ion |
| Repeatability | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
| Serial Interface | USB |
| Computer Requirements | USB port, Windows XP operating system or higher |
| Depth (Metric) | 10.2 cm |
| Fuel | 99.99% H2 for FID |
| Temperature Range (English) | 14°F to 113°F |
| Frequency | 50/60 Hz |
| Portable Operation Time | Minimum 10 hours |
| Temperature Range (Metric) | -10°C to 45°C |
Mettler Toledo™ InLab™ 605-ISM Dissolved Oxygen Sensors
For use with the SevenExcellence™ bench meter and the SevenGo Pro™ portable instrument.
MSA™ ALTAIR™ Single-Gas Detector
Factory-calibrated detector offers two-year, maintenance-free service life
| Height (Metric) | 2.54 cm |
|---|---|
| Warranty | 2 Years |
| Width (English) | 2 in. |
| Length (Metric) | 8.63 cm |
| Length (English) | 3.4 in. |
| Humidity Range | 10 to 95% |
| Width (Metric) | 5.08 cm |
| Alarm Types | Audible, visual, vibrating |
| Dimensions (L x W x H) | 3.4 x 2 x 1 in. (8.63 x 5.08 x 2.54cm) |
| IP Rating | IP67 |
| Temperature Range (English) | -4°F to +122°F |
| Weight (English) | 4 oz. |
| Temperature Range (Metric) | -20°C to +50°C |
| Weight (Metric) | 113g |
| Height (English) | 1 in. |
MSA™ ALTAIR™ Pro Single-Gas Detectors (Alternate Setpoint Models)
Provides worry-free performance and stands up to the roughest handling in even the toughest industrial environments
| Height (Metric) | 2.54 cm |
|---|---|
| Warranty | 2 Years |
| Width (English) | 2 in. |
| Length (Metric) | 8.63 cm |
| Length (English) | 3.4 in. |
| Humidity Range | 10 to 95% |
| Width (Metric) | 5.08 cm |
| Alarm Types | Audible, visual, vibrating |
| Dimensions (L x W x H) | 3.4 x 2 x 1 in. (8.63 x 5.08 x 2.54cm) |
| IP Rating | IP67 |
| Temperature Range (English) | -4°F to +122°F |
| Weight (English) | 4 oz. |
| Temperature Range (Metric) | -20°C to +50°C |
| Weight (Metric) | 113g |
| Height (English) | 1 in. |
ChemDAQ™ SafeCide™ 2.1 Hydrogen Peroxide Monitor System - Tablet
The SafeCide™ 2.1 is a tablet based portable monitor designed for real time detection and logging of hydrogen peroxide (H2O2) vapor concentrations up to 20 ppm with 0.1 ppm resolution.
ChemDAQ™ Steri-Trac™ 2 Hydrogen Peroxide Monitor with Acrylic Stand
The Steri-Trac™ 2 Fixed Area Monitor connects with ChemDAQ’s E-Cell™ sensors to continuously monitor and alert you to hazardous hydrogen peroxide levels in the air.