Cytiva Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/C Sheets
Combines fine particle retention with good flow rate. Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/C Sheets are ideal for the collection of suspended solids in potable water, natural and industrial wastes.
| Particle Retention | 1.2 μm |
|---|---|
| Temperature (English) Max. | 932°F |
| Shape | Sheet |
| Description | GE’s Whatman filter paper Grade GF/C glass filters offer a good flow rate and loading capacity that support total suspended solids analysis. |
| Temperature (Metric) Max | 500°C |
| Grade | Grade GF/C |
| Material | Borosilicate Glass |
| Thickness (Metric) | 260 μm |
| Flow Rate | 10.5 sec./100mL |
| Type | Filter |
| Basis Weight | 53 g/m2 |
| Format | Sheet |
| Thickness (English) | 0.01 in. |
| Waterflow Rate | 105 mL/min |
MilliporeSigma™ Glass Fiber Filters Without Binder, 1.2 μm
Hydrophilic Glass Fiber without Binder Resin filter
| Wettability | Hydrophilic |
|---|---|
| Type | Filter Membranes |
| Temperature (Metric) Max | 500°C |
| Color | White |
| Filter Type | Depth Filter |
| Surface Type | Plain |
| Autoclavable | Autoclavable |
| Sterility | Sterile |
Sartorius Glass Fiber (GF) Pre-filters
Use as a depth filter for larger totally filterable volumes. Sartorius Glass Fiber (GF) Pre-filters are made of borosilicate glass microfibers and are ideal for use as a pre-filter in clarification and sterile filtration. Available in a range of filter disc diameters.
| Particle Retention | 2.6 μm |
|---|---|
| Temperature (English) Max. | 428°F |
| Temperature (Metric) Max | 220°C |
| Color | White |
| Grade | 13400 |
| Material | Borosilicate Glass Microfiber |
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | Used as a depth prefilter high particle loading capacity |
| Sterility | Non-sterile |
| Thickness (Metric) | 550 μm |
| Flow Rate | 295 to 381mL/min. |
| Format | Disc |
| For Use With (Equipment) | Filtration Systems |
| Autoclavable | Autoclavable |
Cytiva Whatman™ Ready-to-Use Glass Microfiber Filters, Grade 934-AH™
Pre-washed and pre-weighed to eliminate filter pre-treating which streamlines laboratory processes. Widely used for total suspended solids analysis.
Sartorius MGC Grade Glass Microfiber Filters without Binder
Binder free MGC Grade Glass Microfiber Filters are suitable for analytical and gravimetric analyses. They are also used as prefilter.
| Particle Retention | 1.2 μm |
|---|---|
| Temperature (English) Max. | 932°F to 1022°F |
| Filtration Time | 66 sec. |
| Air Resistance | 51 mbar |
| Temperature (Metric) Max | 500°C to 550°C |
| Color | White |
| Sample Volume | 320 mL |
| Grade | MGC |
| Material | Borosilicate Glass Microfiber |
| Sterility | Non-sterile |
| Thickness (Metric) | 0.25 mm |
| Type | Glass Microfiber Filter |
| Format | Disc |
| For Use With (Equipment) | Filtration Systems |
| Thickness (English) | 0.009 in. |
Sartorius MGD Grade Glass Microfiber Filters w/o Binder
Binder free glass microfiber filters are suitable for analytical and gravimetric analyses. They are also used as prefilter.
Sartorius MGA Grade Glass Microfiber Filters w/o Binder
Binder free glass microfiber filters are suitable for analytical and gravimetric analyses. They are also used as prefilter.
| Particle Retention | 1.6 μm |
|---|---|
| Temperature (English) Max. | 932°F |
| Filtration Time | 40 sec. |
| Air Resistance | 36mbar |
| Temperature (Metric) Max | 500°C |
| Color | White |
| Sample Volume | 435 mL |
| Grade | MGA |
| Material | Borosilicate Glass Microfiber |
| For Use With (Application) | Clarification of buffer and reagent solutions |
| Sterility | Non-sterile |
| Thickness (Metric) | 0.25 mm |
| Type | Glass Microfiber Filter |
| Format | Disc |
| For Use With (Equipment) | Filtration Systems |
| Thickness (English) | 0.009 in. |
| Filter Type | Net Filter |
Cytiva Whatman™ Grade 934-AH™ RTU Glass Microfiber Filter
Permits rapid passage of very large sample volumes without blockage for collection of suspended solids in potable, natural, and industrial waters
Cytiva Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/A
Combines high loading capacity with fine particle retention. Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/A are ideal for gravimetric determination of airborne particulates, stack sampling and absorption methods of air pollution monitoring.
GVS Glass Microfiber Filter, 0.7 μm
GVS Glass Microfiber Filters are binder-free with a GSM of 75 g/m2.
| Pore Size | 0.7 μm |
|---|---|
| Type | Membrane Filter |
| Material | Glass Fiber |
| Filter Type | Microfilter |
| Sterility | Non-sterile |
GVS PreSep™ 37 mm Glass Fiber Disc
Glass fiber is biologically inert, autoclavable and highly resistant to oxidizing agents and weak acids. Glass fiber can be used to extend the life of a final filter as a prefilter or they can be used alone for low cost sample clarification.
GVS™ Pre-Sep™ Glass Fiber Membranes Without Binders
Glass prefilters without binders are designed to avoid binder extractables during solvent filtration or gravimetric analysis
Ahlstrom™ Glass Microfiber Filter Papers - Grade 151
For retention comparable to membrane filters while providing higher flow and loading capacity