Sartorius Glass Fiber (GF) Pre-filters
Use as a depth filter for larger totally filterable volumes. Sartorius Glass Fiber (GF) Pre-filters are made of borosilicate glass microfibers and are ideal for use as a pre-filter in clarification and sterile filtration. Available in a range of filter disc diameters.
Particle Retention | 2.6 μm |
---|---|
Temperature (English) Max. | 428°F |
Temperature (Metric) Max | 220°C |
Color | White |
Grade | 13400 |
Material | Borosilicate Glass Microfiber |
Hydrophobicity | Hydrophilic |
For Use With (Application) | Used as a depth prefilter high particle loading capacity |
Sterility | Non-sterile |
Thickness (Metric) | 550 μm |
Flow Rate | 295 to 381mL/min. |
Format | Disc |
For Use With (Equipment) | Filtration Systems |
Autoclavable | Autoclavable |
Sartorius MGD Grade Glass Microfiber Filters w/o Binder
Binder free glass microfiber filters are suitable for analytical and gravimetric analyses. They are also used as prefilter.
Cytiva Whatman™ Glass Fiber Filter Papers - Grade 31
Offers fine particle retention and high flow rate, as well as good loading capacity
Cytiva Whatman™ Glass Microfiber Filters with Organic Binder, Grade GF 10
For use as a weighing aid for infrared weighing, and as a roll filter in automatic air filtration units
MilliporeSigma™ Filter Support Pads

Reinforce filters or use as spacers between filters. Filter Support Pads are available in absorbant cellulose pads to support filters in monitors or woven Dacron™ mesh spacers designed for use between filters. Available in diameters from 13mm to 124mm.
Particle Retention | 0.2 to 0.6 μm |
---|---|
Temperature (English) Max. | 220°F |
Temperature (Metric) Max | 105°C |
Color | White |
Quantity | 100Pack. |
Grade | AP10 |
Material | Cellulose Fiber |
Hydrophobicity | Hydrophilic |
For Use With (Application) | Used as filter supports in Millipore™ monitors for contamination analysis for drying filters |
Thickness (Metric) | 0.8 to 1 mm |
Flow Rate | 5.8 mL/minx cm2 |
Wettability | Hydrophilic |
Thickness (English) | 0.031 to 0.039 in. |
Filter Type | Depth Filter |
Surface Type | Plain |
Cytiva Whatman™ Glass Microfiber Prefilter, 1μm Particle Retention Rating
Multilayer graded density filters for rapid and efficient filtration of samples with high solids content. Whatman™ Glass Microfiber Prefilters are designed with a coarse glass filter top layer (10μm) meshed with a finer layer. The multigrade glass filter traps larger particles in its pores of the coarse layer, medium-sized particles in the interface meshing, and smaller particles in the interstices of the fine layer.
Thickness (Metric) | 730 μm |
---|---|
Particle Retention | >1 μm |
Type | Prefilter |
Shape | Circle |
Format | Disc |
Description | GE’s Whatman GMF 150 prefilters are multilayer graded density filters for rapid and efficient filtration of samples with high solids content. |
Airflow Rate | 3.1 sec./100 mL/1.56 cm2 |
Grade | Grade GMF 150 |
Material | Borosilicate Glass |
For Use With (Application) | Prefilter with high loading capacity and good flow rates. |
Waterflow Rate | 222 mL/min. |
Cytiva Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/A Sheets
Combines high loading capacity with fine particle retention. Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/A Sheets are ideal for gravimetric determination of airborne particulates, stack sampling and absorption methods of air pollution monitoring.
Particle Retention | 1.6 μm |
---|---|
Temperature (English) Max. | 932°F |
Shape | Sheet |
Description | GE’s Whatman Grade GF/A glass microfiber filters feature fine retention. GF/A filters are suitable for water quality parameter measurement and air filtration applications. |
Temperature (Metric) Max | 500°C |
Grade | Grade GF/A |
Material | Borosilicate Glass |
For Use With (Application) | Used for high-efficiency general purpose laboratory filtration, including water pollution monitoring of effluents, for filtration of water, foodstuff analyses, protein filtration, and radioimmunoassay of weak β emitters. |
Thickness (Metric) | 260 μm |
Flow Rate | 13 sec./100mL |
Type | Fine Retention Filter |
Format | Sheet |
Thickness (English) | 0.01 in. |
Waterflow Rate | 143 mL/min |
Cytiva Whatman™ Binder-Free Glass Microfiber Prefiters, Grade GF/D Sheets
Functions as a prefilter when used with GF/B microfiber filters. Whatman™ Binder-Free Glass Microfiber Prefilters, Grade GF/D Sheets provide efficient membrane protection, especially during liquid scintillation counting.
Cytiva Moisture Test Paper
Moisture test paper for use when drying samples during moisture assessment
Sartorius Extra Thick Glass Fiber (GF) Pre-filters
Glass fiber prefilters, depth pre filters, for larger totally filterable volumes in clarification and sterile filtration.
Type | Glass Microfiber Filter |
---|---|
Temperature (English) Max. | 932°F |
Format | Disc |
For Use With (Equipment) | Filtration Systems |
Temperature (Metric) Max | 500°C |
Color | White |
Material | Borosilicate Glass Microfiber |
Filter Type | Net Filter |
Hydrophobicity | Hydrophilic |
For Use With (Application) | Prefiltration of clean solutions such as tissue culture media |
Autoclavable | Autoclavable |
Sterility | Non-sterile |
GVS PreSep™ 124 mm Glass Fiber Disc
Glass fiber is biologically inert, autoclavable and highly resistant to oxidizing agents and weak acids. Glass fiber can be used to extend the life of a final filter as a prefilter or they can be used alone for low cost sample clarification.
Material | Borosilicate Glass Fiber |
---|
GVS PreSep™ 13 mm Glass Fiber Disc
Glass fiber is biologically inert, autoclavable and highly resistant to oxidizing agents and weak acids. Glass fiber can be used to extend the life of a final filter as a prefilter or they can be used alone for low cost sample clarification.
Ahlstrom™ Glass Microfiber Filter Papers - Grade 111
For general purpose use and atmospheric and water pollution monitoring
Thickness (Metric) | 0.28 mm |
---|---|
Flow Rate | 5 cfm/ft2 |
Particle Retention | 1.2 μm |
Temperature (English) Max. | 932°F |
Format | Disc |
Thickness (English) | 0.01 in. |
Temperature (Metric) Max | 500°C |
Grade | 111 |
Material | Borosilicate Glass |
For Use With (Application) | General purpose use and atmospheric/water pollution monitoring |
Ahlstrom™ Glass Microfiber Filter Papers - Grade 151
For retention comparable to membrane filters while providing higher flow and loading capacity