Syringeless and Syringe Filters
- (2)
- (8)
- (16)
- (370)
- (9)
- (138)
- (1)
- (520)
- (1)
- (1)
- (18)
- (20)
- (2)
- (6)
- (23)
- (1)
- (22)
- (1)
- (3)
- (5)
- (2)
- (1)
- (3)
- (5)
- (2)
- (30)
- (3)
- (1)
- (1)
- (1)
- (14)
- (4)
- (1)
- (2)
- (8)
- (94)
- (4)
- (27)
- (8)
- (12)
- (7)
- (5)
- (6)
- (6)
- (1)
- (7)
- (44)
- (1)
- (19)
- (9)
- (2)
- (161)
- (118)
- (3)
- (1)
- (112)
- (42)
- (56)
- (132)
- (28)
- (4)
- (2)
- (1)
- (8)
- (2)
- (4)
- (8)
- (11)
- (83)
- (24)
- (751)
- (177)
- (9)
- (645)
- (1)
- (20)
- (1)
- (33)
- (13)
- (1)
- (108)
- (230)
- (6)
Filtered Search Results
Sartorius Minisart™ SRP Syringe Filters, Sterile
Ready-to-use units for simple, rapid and reliable ultracleaning of small volume samples for the HPLC or GC analysis
Sartorius Minisart™ NML Syringe Filter, Nonsterile
Provides fast and reliable filtration of small to medium volumes, complete with ready-to-connect filter units. Sartorius Minisart™ NML Syringe Filters, Nonsterile eliminate time consuming preparatory work, such as changing out the filter and cleaning the filtration system.
| Disposable | Single-use |
|---|---|
| Housing Material | Meta acrylate butadiene styrene polymerisate (MBS) |
| Temperature (Metric) Max | 50°C |
| Volume (Metric) | 200 mL |
| Quantity | 500 Pk. |
| Sample Volume | 1 to 200 mL |
| Hydrophobicity | Hydrophilic |
| Sterility | Non-sterile |
| Filtration Area | 6.2 cm2 |
| Type | NML Syringe Filter |
| For Use With (Equipment) | Syringe |
| Diameter (Metric) | 28 mm |
| Inlet Style | Female Luer Lock |
| Packaging | Nonsterile, bulk packed |
| Filter Type | Syringe Filter |
| Prefilter | No |
| Hold up Volume (After Air Purge) | 0.15 mL |
Sartorius Minisart™ SRP25 Syringe Filters
Minisart™ SRP with chemically inert hydrophobic PTFE is suitable for venting as well as harsh solvents with a pH of 1 - 14. Type 1757A with a pore size of 0.2 μm can be used for sterile venting. It has hose barb outlet. Version Q is a non-sterile bulk pack. Units can be sterilized by autoclaving or EO.
Choice™ PVDF (Hydrophobic) Syringe Filters
Use Choice PVDF (hydrophobic) Syringe Filters for general biological filtration, especially when high protein recovery is desired.
| Disposable | Single-use |
|---|---|
| Type | Syringe Filter |
| Housing Material | Solvent Resistent, Low-Extractable Polypropylene |
| Material (Membrane) | PVDF (Hydrophobic) |
| Quantity | 100/Pk. |
| Pressure Rating | 90 psi |
| For Use With (Application) | HPLC, SPE |
| Prefilter | No |
| Sterility | Non-sterile |
| Product Line | Choice |
Thermo Scientific™ Titan3™ Regenerated Cellulose Syringe Filters
With a robust design that includes a reinforcing outer ring configuration and integral pre-filter, Titan3 Syringe Filters are an ideal choice for high solids applications or where maximum confidence is required.
Thermo Scientific™ Titan3™ Redi-Pac HPLC Syringe Filters
Choose these filters for maximum confidence or for high-solids applications.
Cytiva Whatman™ Uniflo Syringe Filters, 0.22μm, PES filtration media
Hydrophilic PES membranes are designed for stability in low pH, have low levels of extractables, and exhibit low protein binding, making them suitable for many aqueous and organic solvents.
| Pore Size | 0.22 μm |
|---|---|
| Outlet Style | Male Slip Luer |
| Inlet Style | Female Luer Lock |
| Housing Material | Polypropylene |
| Material (Membrane) | PES |
| Quantity | 500/Pk. |
| Pressure Rating | 67.5 psi |
| Material | PTFE |
| Sterility | Non-sterile |
| Filtration Area | 0.65 cm2 |
Cytiva Whatman™ GD/X PES Syringe Filters
Processes three to seven times more sample volume than filters without prefilter. Whatman™ GD/X PES Syringe Filters are specifically designed for filtration of viscous or otherwise hard-to-filter samples with high solids content.
| Disposable | Single-use |
|---|---|
| Type | Syringe Filter |
| Dimensions (L x W x H) | 21.6 x 29.8 mm |
| Outlet Style | Male Luer |
| Inlet Style | Female Luer Lock |
| Housing Material | Pigment free polypropylene (PP) |
| Material (Membrane) | PES |
| Volume (Metric) | >10 mL |
| Sterility | Non-sterile |
Sartorius Minisart™ NY Syringe Filters: Nonsterile
For rapid small volume filtration of both aqueous and solvent-based samples with maximum user convenience.
| Disposable | Single-use |
|---|---|
| Type | Syringe Filter |
| Outlet Style | Luer Slip |
| For Use With (Equipment) | Syringe |
| Housing Material | Polypropylene |
| Filter Type | Syringe Filter |
| For Use With (Application) | For rapid small volume filtration of both aqueous and solvent-based samples with maximum user convinience |
| Sterility | Non-sterile |
| Disposable | Single-use |
|---|---|
| Type | Filter |
| For Use With (Equipment) | Syringe |
| Material (Membrane) | Glass Fiber |
| Temperature (Metric) Max | 55°C |
| Volume (Metric) | 450 μL |
| Filter Type | Syringe Filter |
| Hold up Volume (After Air Purge) | 450 μL |
| Sterility | Non-sterile |
| Max. Pressure | 5 bar |
Thermo Scientific™ Target2™ GMF (Glass MicroFiber) Syringe Filters
Ensure cleaner sample extracts by removing interfering materials and fine particles prior to injection with these robust GMF (glass microfiber) syringe filters.
| Disposable | Single-use |
|---|---|
| Housing Material | Polypropylene |
| Material (Membrane) | Glass Microfiber |
| Quantity | 100/Pk. |
| Pressure Rating | 150 psi |
| Diameter (Metric) Membrane | 30 mm |
| For Use With (Application) | HPLC, SPE |
| Sterility | Non-sterile |
| Type | Syringe Filter |
| Diameter (Metric) | 30 mm |
| Certifications/Compliance | Target Polypropylene Syringe Filter Housings Meet The Requirements of 21 CFR 177.1520. |
| Prefilter | No |
| Hold up Volume (After Air Purge) | <157 μL |
| Product Line | Target2 |
Thermo Scientific™ Titan3™ Cellulose Acetate Syringe Filters
Ensure cleaner sample extracts by removing interfering materials and fine particles prior to injection with these robust cellulose acetate (CA) syringe filters.
| Disposable | Single-use |
|---|---|
| Type | Syringe Filter |
| Housing Material | Polypropylene |
| Material (Membrane) | Cellulose Acetate |
| Certifications/Compliance | Titan3 Polypropylene Syringe Filter Housings Meet The Requirements of 21 CFR 177.1520. Membrane: HPLC Certified Cellulose Acetate. |
| For Use With (Application) | Sample Filtration: tissue culture media; sensitive biological samples |
| Prefilter | No |
| Sterility | Non-sterile |
| Product Line | Titan3 |
Thermo Scientific™ Titan3™ GMF (Glass MicroFiber) Syringe Filters
Ensure cleaner sample extracts by removing interfering materials and fine particles prior to injection with these robust GMF (glass microfiber) syringe filters.
| Disposable | Single-use |
|---|---|
| Housing Material | Polypropylene |
| Material (Membrane) | Glass Microfiber |
| Volume (Metric) | <137 μL (Hold Up) |
| Quantity | 100 Pk. |
| Pressure Rating | 210 psi |
| For Use With (Application) | Sample Filtration: dissolution testing; general use |
| Sterility | Non-sterile |
| Type | Syringe Filter |
| Diameter (Metric) | 30 mm |
| Filter Type | Syringe Filter |
| Certifications/Compliance | Titan3 Polypropylene Syringe Filter Housings Meet The Requirements of 21 CFR 177.1520. |
| Prefilter | No |
| Hold up Volume (After Air Purge) | <157 μL |
| Product Line | Titan3 |
Corning™ Syringe Filters, Nonsterile
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Manufactured with PTFE for the highest degree of chemical resistance. Corning™ Syringe Filters are used with syringes that serve as both the fluid reservoir and the pressure source. They are 100% integrity tested.
Cytiva Whatman™ Puradisc PVDF Syringe Filters: Nonsterile
Designed for high tensile strength, high solvent resistance, and low protein binding. Cytiva Whatman™ Puradisc PVDF Syringe Filters: Nonsterile are well-suited for biomedical filtration, sterilization filtration, and HPLC sample preparation.
| Dimensions (L x W x H) | 22.9 x 28.4 mm |
|---|---|
| Outlet Style | Male Luer |
| Diameter (Metric) | 25 mm |
| Inlet Style | Female Luer Lock |
| Housing Material | Pigment Free Polypropylene (PP) |
| Material (Membrane) | PVDF |
| Volume (Metric) | Up to 100 mL |
| Pressure Rating | 5.2 bar (75 psi) |
| Sterility | Non-sterile |
| Filtration Area | 4.2 cm2 |