Gas and Vapor Detection
Filtered Search Results
| Components Measured | Water Vapor |
|---|---|
| Quantity | 10 |
ChemDAQ™ Steri-Trac™ 2+ Peracetic Acid Monitor with Acrylic Stand
Steri-Trac™ 2+ Peracetic Acid Monitor provides real-time PAA detection with visual/audible alarms. Includes an acrylic stand for flexible placement. Ideal for monitoring sterilization areas and ensuring safe working conditions.
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only with Enhanced Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Width (English) | 9 in. |
|---|---|
| Response Time | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
| Detection Limits | 0.5 ppm of methane |
| Width (Metric) | 22.9 cm |
| Detector Type | Flame Ionization Detector (FID) |
| Flow Rate | 1 L/min., nominal at sample probe inlet |
| Components Measured | Most Organic and Inorganic Compounds |
| Accuracy | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
| Battery Life | 10 hours at 0°C |
| Voltage | 120 V |
| Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Height (English) | 11.5 in. |
| Height (Metric) | 29.2 cm |
| Warranty | One year from date of shipment |
| Depth (English) | 4 in. |
| Concentration | 0 to 30,000 ppm (methane) |
| Battery Type | Lithium-ion |
| Repeatability | ±2% at 500 ppm of methane |
| Serial Interface | USB |
| Computer Requirements | USB port, Windows XP operating system or higher |
| Depth (Metric) | 10.2 cm |
| Fuel | 99.99% H2 for FID |
| Temperature Range (English) | 14°F to 113°F |
| Frequency | 50/60 Hz |
| Portable Operation Time | Minimum 10 hours |
| Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID with Sampling Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Width (English) | 9 in. |
|---|---|
| Response Time | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
| Detection Limits | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
| Width (Metric) | 22.9 cm |
| Detector Type | Dual Configured with FID and PID |
| Flow Rate | 1 L/min., nominal at sample probe inlet |
| Components Measured | Most Organic and Inorganic Compounds |
| Accuracy | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
| Battery Life | 10 hours at 0°C |
| Voltage | 120 V |
| Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Height (English) | 11.5 in. |
| Height (Metric) | 29.2 cm |
| Warranty | One year from date of shipment |
| Depth (English) | 4 in. |
| Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
| Battery Type | Lithium-ion |
| Repeatability | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
| Serial Interface | USB |
| Computer Requirements | USB port, Windows XP operating system or higher |
| Depth (Metric) | 10.2 cm |
| Fuel | 99.99% H2 for FID |
| Temperature Range (English) | 14°F to 113°F |
| Frequency | 50/60 Hz |
| Portable Operation Time | Minimum 10 hours |
| Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID (No Probes)
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Width (English) | 9 in. |
|---|---|
| Response Time | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
| Detection Limits | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
| Width (Metric) | 22.9 cm |
| Detector Type | Dual Configured with FID and PID |
| Flow Rate | 1 L/min., nominal at sample probe inlet |
| Components Measured | Most Organic and Inorganic Compounds |
| Accuracy | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
| Battery Life | 10 hours at 0°C |
| Voltage | 120 V |
| Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Height (English) | 11.5 in. |
| Height (Metric) | 29.2 cm |
| Warranty | One year from date of shipment |
| Depth (English) | 4 in. |
| Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
| Battery Type | Lithium-ion |
| Repeatability | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
| Serial Interface | USB |
| Computer Requirements | USB port, Windows XP operating system or higher |
| Depth (Metric) | 10.2 cm |
| Fuel | 99.99% H2 for FID |
| Temperature Range (English) | 14°F to 113°F |
| Frequency | 50/60 Hz |
| Portable Operation Time | Minimum 10 hours |
| Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID with Enhanced Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Width (English) | 9 in. |
|---|---|
| Response Time | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
| Detection Limits | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
| Width (Metric) | 22.9 cm |
| Detector Type | Dual Configured with FID and PID |
| Flow Rate | 1 L/min., nominal at sample probe inlet |
| Components Measured | Most Organic and Inorganic Compounds |
| Accuracy | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
| Battery Life | 10 hours at 0°C |
| Voltage | 120 V |
| Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Height (English) | 11.5 in. |
| Height (Metric) | 29.2 cm |
| Warranty | One year from date of shipment |
| Depth (English) | 4 in. |
| Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
| Battery Type | Lithium-ion |
| Repeatability | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
| Serial Interface | USB |
| Computer Requirements | USB port, Windows XP operating system or higher |
| Depth (Metric) | 10.2 cm |
| Fuel | 99.99% H2 for FID |
| Temperature Range (English) | 14°F to 113°F |
| Frequency | 50/60 Hz |
| Portable Operation Time | Minimum 10 hours |
| Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID with Enhanced & Sampling Probes
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Width (English) | 9 in. |
|---|---|
| Response Time | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
| Detection Limits | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
| Width (Metric) | 22.9 cm |
| Detector Type | Dual Configured with FID and PID |
| Flow Rate | 1 L/min., nominal at sample probe inlet |
| Components Measured | Most Organic and Inorganic Compounds |
| Accuracy | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
| Battery Life | 10 hours at 0°C |
| Voltage | 120 V |
| Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Height (English) | 11.5 in. |
| Height (Metric) | 29.2 cm |
| Warranty | One year from date of shipment |
| Depth (English) | 4 in. |
| Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
| Battery Type | Lithium-ion |
| Repeatability | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
| Serial Interface | USB |
| Computer Requirements | USB port, Windows XP operating system or higher |
| Depth (Metric) | 10.2 cm |
| Fuel | 99.99% H2 for FID |
| Temperature Range (English) | 14°F to 113°F |
| Frequency | 50/60 Hz |
| Portable Operation Time | Minimum 10 hours |
| Temperature Range (Metric) | -10°C to 45°C |
Mettler Toledo™ InLab™ 605-ISM Dissolved Oxygen Sensors
For use with the SevenExcellence™ bench meter and the SevenGo Pro™ portable instrument.
StatLab™ SafeTech Vapor Monitor
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Vapor monitoring is important to ensure the safety of employees and comply with OSHA guidelines.
| Type | Single Gas Detector |
|---|---|
| For Use With (Equipment) | Laboratory |
MSA™ ALTAIR™ Single-Gas Detector
Factory-calibrated detector offers two-year, maintenance-free service life
| Height (Metric) | 2.54 cm |
|---|---|
| Warranty | 2 Years |
| Width (English) | 2 in. |
| Length (Metric) | 8.63 cm |
| Length (English) | 3.4 in. |
| Humidity Range | 10 to 95% |
| Width (Metric) | 5.08 cm |
| Alarm Types | Audible, visual, vibrating |
| Dimensions (L x W x H) | 3.4 x 2 x 1 in. (8.63 x 5.08 x 2.54cm) |
| IP Rating | IP67 |
| Temperature Range (English) | -4°F to +122°F |
| Weight (English) | 4 oz. |
| Temperature Range (Metric) | -20°C to +50°C |
| Weight (Metric) | 113g |
| Height (English) | 1 in. |
Dräger™ X-am™ 2500 Multi-Gas Detection
Instrument provides personal protection in industrial, mining, refinery, and confined space applications. Lightweight and easy to operate, it shows all readings at once on the large LCD and stores peak values, which are easily reset.
MSA™ ALTAIR™ Pro Single-Gas Detectors (Alternate Setpoint Models)
Provides worry-free performance and stands up to the roughest handling in even the toughest industrial environments
| Height (Metric) | 2.54 cm |
|---|---|
| Warranty | 2 Years |
| Width (English) | 2 in. |
| Length (Metric) | 8.63 cm |
| Length (English) | 3.4 in. |
| Humidity Range | 10 to 95% |
| Width (Metric) | 5.08 cm |
| Alarm Types | Audible, visual, vibrating |
| Dimensions (L x W x H) | 3.4 x 2 x 1 in. (8.63 x 5.08 x 2.54cm) |
| IP Rating | IP67 |
| Temperature Range (English) | -4°F to +122°F |
| Weight (English) | 4 oz. |
| Temperature Range (Metric) | -20°C to +50°C |
| Weight (Metric) | 113g |
| Height (English) | 1 in. |
ChemDAQ™ SafeCide™ 2.1 Hydrogen Peroxide Monitor System - Tablet
The SafeCide™ 2.1 is a tablet based portable monitor designed for real time detection and logging of hydrogen peroxide (H2O2) vapor concentrations up to 20 ppm with 0.1 ppm resolution.
ChemDAQ™ Steri-Trac™ 2 Hydrogen Peroxide Monitor with Acrylic Stand
The Steri-Trac™ 2 Fixed Area Monitor connects with ChemDAQ’s E-Cell™ sensors to continuously monitor and alert you to hazardous hydrogen peroxide levels in the air.