Cytiva Capto™ HiRes Ion Exchange Chromatography Columns
Prepacked columns for high-resolution purification of proteins and other biomolecules by ion exchange chromatography. They are well-suited for the preparation of highly pure proteins for structural studies and protein analysis.
| Particle Size | ∼9μm |
|---|---|
| Flow Rate | 0.5 to 2 mL/min. |
| Packing Material | Highly Cross-Linked Agarose |
| Temperature (Metric) | 4°C to 40°C |
| Column Type | Ion Exchange Column |
| pH | 2 to 12 |
| Quantity | 1 Ea. |
| Material | Tricorn™ Glass |
| For Use With (Application) | Anaylsis or Purification of Proteins and Nucleic Acids |
| Particle Shape | Spherical |
| Max. Pressure | 4 MPa (40 bar) |
| Product Line | Capto |
Cytiva HiScale™ Columns Packed with Superdex™ Increase or Superose™ Increase Resins
Similar to the new-generation Superdex™ Increase and Superose™ Increase Size Exclusion Chromatography (SEC) Columns, but for use with purifying larger volumes of up to 8.5 mL
| Type | Column |
|---|---|
| Content And Storage | Store at 4°C to 30°C, 20% Ethanol |
| For Use With | Size Exclusion Chromatography (SEC) |
| Quantity | 1 Ea. |
| Max. Pressure | 2 MPa |
| Particle Size | 15 μm |
|---|---|
| Ligand Type | Matrix surface |
| Type | Reversed Phase Column |
| Endcapped | No |
| Packing Material | Polystyrene/Divinyl Benzene |
| pH | 1 to 12 |
| Particle Shape | Monosized |
DWK Life Sciences Kimble™ FLEX-COLUMNS™ Economy Chromatography Columns
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
FLEX-COLUMNS™ are economical and easy-to-use. Short columns are typically used for ion exchange chromatography, sample desalting and semi-disposable applications. Long columns are ideally suited for gel filtration and adsorption chromatography.
| Type | Chromatography Column |
|---|
Thermo Scientific™ DNAPac™ RP Columns
Get high resolution LC and LC-MS separation of oligonucleotides, including double-stranded (ds) DNA/RNA fragments, using these DNAPac reversed phase columns.
Thermo Scientific™ DNAPac™ PA100 Oligonucleotide HPLC Columns
Features strong anion-exchange resin for high-resolution analysis and purification of synthetic and modified oligonucleotides.
| Pore Size | Nonporous |
|---|---|
| Particle Size | 13 μm |
| Stationary Phase | Quaternary Ammonium |
| Temperature | 90°C |
| Column Type | Ion Exchange |
| pH | 2 to 12.5 |
| Quantity | Each |
| Max. Pressure | 4000 psi (275 bar) |
Thermo Scientific™ Acclaim™ PepMap™ 100 C18 HPLC Columns
Use for high-resolution tryptic, natural, and synthetic peptide analyses. Its high loading capacity is exceptional for low abundant peptides in complex proteomic samples.
| Pore Size | 100 Å |
|---|---|
| Stationary Phase | C18 |
| Phase | Reversed Phase |
| USP Type | L1 |
DWK Life Sciences Kimble™ Kontes™ FlexColumn™ Economy Columns
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Ideal for use with FPLC™ systems, peristaltic pumps, or gravity flow to 15psi
| Pore Size | 20 μm |
|---|---|
| Type | Economy Chromatography Column |
| Sterilization Method | 2N NaOH or 100% Ethanol |
| Temperature (Metric) Range | 0 to 50°C |
| Endcapped | Yes |
| Support Material | HDPE |
| Diameter (Metric) Inner | 25 mm |
| Material | Borosilicate Glass Type I Class A |
| For Use With (Application) | Ion exchange, affinity, gel filtration and hydrophobic interaction media |
| Cross Sectional Area | 4.91cm3 |
| Connector Types | Male luer lock |
| Max. Pressure | 14.5 psi |
Thermo Scientific™ Hypersil™ ODS C18 Columns
Use as a general purpose C18 phase for acidic and neutral analytes.
| Pore Size | 120 Å |
|---|---|
| Carbon Load | 10% |
| Stationary Phase | C18 |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 170 m²/g |
| USP Type | L1 |
Thermo Scientific™ Accucore™ aQ C18 Polar Endcapped HPLC Columns
Use this column, with its specially designed solid core, for the separation of compounds in highly aqueous mobile phases.
| Pore Size | 80 Å |
|---|---|
| Stationary Phase | C18 |
| Temperature | 70°C |
| Phase | Reversed Phase |
| Endcapped | Polar |
| Column Type | Reversed Phase |
| Surface Area | 130 m²/g |
| Max. Pressure | 14500 psi (1000 bar) |
| Particle Size | 2.6 μm |
| Carbon Load | 9% |
| Packing Material | Spherical, Solid Core, Ultrapure Silica |
| pH | 2 to 9 |
| Particle Shape | Spherical Solid Core |
| Product Line | Accucore |
| USP Type | L1 |
Thermo Scientific™ Accucore™ C18 HPLC Columns
Use this column, with its specially designed solid core, for a broad range of nonpolar analytes across multiple applications.
| Pore Size | 80 Å |
|---|---|
| Particle Size | 2.6 μm |
| Carbon Load | 9% |
| Stationary Phase | C18 |
| Temperature | 70°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| pH | 1 to 11 |
| Surface Area | 130 m²/g |
| Particle Shape | Spherical Solid Core |
| USP Type | L1 |
Thermo Scientific™ MAbPac™ SCX-10 HPLC Columns
Use these strong cation-exchange columns for high-resolution, high efficiency analysis of monoclonal antibodies (mAbs) and associated variants.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
| Pore Size | Nonporous |
|---|---|
| Temperature | Ambient to 60°C |
| Phase | Ion Exchange |
| Column Type | Ion Exchange |
| pH | 2 to 12 |
Thermo Scientific™ ProPac™ WCX-10 HPLC Columns
Separate proteins and their variants using these weak cation-exchange columns with exceptionally high resolution.
| Pore Size | Nonporous |
|---|---|
| Particle Size | 10 μm |
| Stationary Phase | Carboxylate |
| Temperature | 60°C |
| Phase | Ion Exchange |
| Column Type | Ion Exchange |
| pH | 2 to 12 |
| Quantity | Each |
| Product Line | ProPac |
Thermo Scientific™ PepMap™ Neo Trap Cartridge
Use the Thermo Scientific™ PepMap™ Neo Trap Cartridge with PepMap™ Neo UHPLC Columns to filter impurities from your peptide mapping samples.
Thermo Scientific™ DNAPac™ PA200 Oligonucleotide HPLC Columns
Enjoy strong anion exchange for high-resolution analysis and purification of synthetic oligonucleotides with Thermo Scientific™ DNAPac™ PA200 Oligonucleotide HPLC Columns.
| Pore Size | Nonporous |
|---|---|
| Stationary Phase | Quaternary Ammonium |
| Temperature | 85°C |
| Phase | Ion Exchange |
| Column Type | Ion Exchange |
| Quantity | Each |
| Green Features | Responsibly packaged |
| Technique | Bio-LC |
| Product Line | DNAPac |