Autosampler Syringes
Syringes for gas chromatography (GC), liquid chromatography (LC) and HPLC autosamplers; includes fixed-needle and removable-needle formats in various sizes, needle gauges, needle point styles, and terminations; includes zero dead-volume and headspace syringes. Specialty syringes designed for unique applications are also available.
- (2)
- (25)
- (2)
- (20)
- (26)
- (2)
- (175)
- (14)
- (11)
- (54)
- (4)
- (3)
- (3)
- (1)
- (1)
- (20)
- (46)
- (5)
- (1)
- (1)
- (39)
- (1)
- (71)
- (19)
- (41)
- (4)
- (33)
- (1)
- (1)
- (72)
- (63)
- (132)
- (9)
- (12)
- (44)
- (7)
- (2)
- (25)
- (4)
- (75)
- (65)
- (1)
- (1)
- (100)
- (2)
- (1)
- (2)
- (88)
- (2)
- (6)
- (1)
- (6)
- (7)
- (1)
- (2)
- (12)
- (6)
- (5)
- (16)
- (15)
- (16)
- (8)
- (3)
- (3)
- (117)
- (2)
- (10)
- (16)
- (11)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (6)
- (26)
- (19)
- (7)
- (8)
- (6)
- (2)
- (2)
- (9)
- (1)
- (2)
- (2)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (3)
- (1)
- (2)
- (3)
- (1)
- (7)
- (2)
- (11)
- (6)
- (6)
- (2)
- (6)
- (2)
- (3)
- (1)
- (2)
- (6)
- (3)
- (1)
- (3)
- (6)
- (1)
- (5)
- (10)
- (14)
- (1)
- (1)
- (1)
- (2)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (2)
- (1)
- (14)
- (6)
- (7)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (3)
- (6)
- (12)
- (1)
- (1)
- (2)
- (1)
- (8)
- (3)
- (1)
- (4)
- (16)
- (3)
- (9)
- (2)
- (13)
- (2)
- (1)
- (1)
- (8)
- (2)
- (38)
- (2)
- (1)
- (1)
- (1)
- (1)
- (2)
- (2)
- (16)
- (260)
- (1)
- (1)
- (1)
- (1)
- (124)
- (7)
- (4)
- (1)
- (67)
- (230)
- (11)
Filtered Search Results
Hamilton™ 600 Series Syringe, Removable Needle (RN), Sold by MilliporeSigma™ Supelco™
Ideal for dispensing volumes ranging from 0.25 μL to 5 μL. Often used in applications that require one handed operation due to the short stroke length and reinforced plunger.
| Needle Point Number | 3 |
|---|---|
| Quantity | 1 Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),Stainless Steel (Tip) |
| Max. Temperature (Metric) | 115°C |
| Length (Metric) Needle | 51 mm |
| Max. Pressure | 2000 psig (137.9 bar) |
| Diameter (Metric) Inner Needle | 0.13 mm |
| For Use With (Equipment) | Rheodyne |
| Product Type | Microliter™ Syringe |
| Diameter (Metric) Outer | 6.60 mm |
| Connection Type | Removable |
| Max. Temperature (English) | 239°F |
| Diameter (English) Outer | 0.260 in. |
| Needle Point Style | Blunt |
| Diameter (Metric) Outer Needle | 0.711 mm |
| Length (English) Needle | 2 in. |
| Autoclavable | Autoclavable |
| Min. Temperature (Metric) | 10°C |
| Needle Gauge | 22s G |
| Diameter (English) Outer Needle | 0.028 in. |
| Diameter (English) Inner Needle | 0.005 in. |
| Product Line | Hamilton |
Hamilton™ Microliter™ and Gastight™Model 7001 GC Syringes: For Agilent 7673, 7683, 7693 and 6850 ALS
Designed to work with Agilent 7673, 7683, 7693 and 6850 Automatic Liquid Sampler (ALS) gas chromatography (GC) autosamplers
| Needle Point Number | AS |
|---|---|
| Diameter (English) Inner | 0.049 in. |
| Length (Metric) | 43 mm |
| Volume (Metric) | 1 μL |
| Length (English) | 1.7 in. |
| Diameter (Metric) Inner | 1.24 mm |
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger) |
| Max. Temperature (Metric) | 155°C |
| Max. Pressure | 6000 psi |
| For Use With (Equipment) | Agilent 7673, 7683, 6850 Automatic Liquid Sampler, Gas Chromatography Autosamplers |
| Product Type | Microliter Syringe |
| Diameter (Metric) Outer | 6.6 mm |
| Connection Type | Removable |
| Max. Temperature (English) | 239°F |
| Diameter (English) Outer | 0.26 in. |
| Model | 7001 |
| Needle Point Style | Cone |
| Length (English) Needle | 1.71 in. |
| Min. Temperature (Metric) | 10°C |
Hamilton™ CTC and LEAP Technologies GC PAL Autosampler Syringes: Gastight
Designed for use in PAL GC-xt, PAL COMBI-xt, PAL COMBI-xt extended and other autosampler systems
| For Use With (Equipment) | PAL GC-xt, PAL COMBI-xt, PAL COMBI-xt extended and other autosampler systems |
|---|---|
| Product Type | Gastight Syringe |
| Quantity | Ea. |
| Min. Temperature (English) | 68°F |
| Length (English) Needle | 2 in. |
| Autoclavable | Not Autoclavable |
| Min. Temperature (Metric) | 20°C |
Hamilton™ Syringes, 5 μL, Sold by MilliporeSigma™ Supelco™
For use with PerkinElmer™ GC Autosystem and Clarus 500 75 ASN/PE GC
| Needle Point Number | 3 |
|---|---|
| Diameter (English) Inner | 0.014 in. |
| Volume (Metric) | 5 μL |
| Diameter (Metric) Inner | 0.343 mm |
| Quantity | 1 Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),Stainless Steel (Tip) |
| Max. Temperature (Metric) | 50°C |
| Length (Metric) Needle | 70 mm |
| Max. Pressure | 2000 psig (137.9 bar) |
| For Use With (Equipment) | PerkinElmer GC Autosystem |
| Product Type | Microliter™ Syringe |
| Diameter (Metric) Outer | 6.60 mm |
| Connection Type | Cemented |
| Max. Temperature (English) | 122°F |
| Diameter (English) Outer | 0.260 in. |
| Model | 75 N Perkin Elmer |
| Needle Point Style | Blunt |
| Length (English) Needle | 2.75 in. |
| Autoclavable | Not Autoclavable |
| Min. Temperature (Metric) | 10°C |
| Product Line | Hamilton |
| Volume (Metric) | 5 μL |
|---|---|
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),Stainless Steel (Tip) |
| Max. Temperature (Metric) | 50°C |
| Length (Metric) Needle | 43 mm |
| Max. Pressure | 2000 psig (137.9 bar) |
| For Use With (Equipment) | Agilent 7673, 7683, 7693A and 6850 Autosamplers |
| Product Type | Microliter™ Syringe |
| Connection Type | Cemented |
| Max. Temperature (English) | 122°F |
| Length (English) Needle | 1.71 in. |
| Autoclavable | Not Autoclavable |
| Min. Temperature (Metric) | 10°C |
| Product Line | Hamilton |
MilliporeSigma™ Supelco™ SGE Syringes, 10 μL
For use with Varian 8035, 8100, and 8200 GC Autosamplers
Hamilton™ HPLC Syringes, Sold by MilliporeSigma™ Supelco™
May be used for extraction and injection of sample material
| Needle Point Number | 3 |
|---|---|
| Quantity | 1 Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),PTFE (Plunger),Stainless Steel (Tip) |
| Max. Temperature (Metric) | 115°C |
| Length (Metric) Needle | 51 mm |
| For Use With (Equipment) | Rheodyne, SSI, and Valco VISF-2 |
| Product Type | Gastight™ Syringe |
| Connection Type | Removable |
| Max. Temperature (English) | 239°F |
| Needle Point Style | Blunt |
| Diameter (Metric) Outer Needle | 0.72 mm |
| Length (English) Needle | 2 in. |
| Autoclavable | Autoclavable |
| Min. Temperature (Metric) | 10°C |
| Diameter (English) Outer Needle | 0.0283 in. |
| Product Line | Hamilton |
Hamilton™ 800 Series Syringe, Removable Needle (RN), Sold by MilliporeSigma™ Supelco™
Offers the same quality performance as the Hamilton™ 700 Series, but with additional benefits
| Needle Point Number | 2 |
|---|---|
| Quantity | 1 Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),Stainless Steel (Tip) |
| Max. Temperature (Metric) | 115°C |
| Length (Metric) Needle | 51 mm |
| Max. Pressure | 2000 psig (137.9 bar) |
| Product Type | Microliter™ Syringe |
| Max. Temperature (English) | 239°F |
| Needle Point Style | Bevel |
| Length (English) Needle | 2 in. |
| Autoclavable | Autoclavable |
| Min. Temperature (Metric) | 10°C |
| Product Line | Hamilton |
Synthware™ Microliter Sample Syringes - Liquid Phase
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Borosilicate syringes with a blunt tip, for precise sample delivery in volumes ranging from 0.5 μL to 1 mL.
| Disposable | Reusable |
|---|---|
| For Use With (Equipment) | Syringe Needles |
| Product Type | Syringe |
| Connection Type | Slip Tip |
| Color | Clear |
| Graduated | Yes |
| Needle Point Style | Blunt |
| Latex Free | Yes |
| Material | Borosilicate Glass (3.3) |
| For Use With (Application) | Precise Sampling |
| Sterility | Non-sterile |
Hamilton™ Microliter™ PerkinElmer AutoSystem and Clarus 500 GC Autosampler Syringes
Designed for use with Perkin Elmer Autosystem and Clarus 500 gas chromatography (GC) autosamplers
| Diameter (English) Inner | 0.014 in. |
|---|---|
| Length (Metric) | 69.9 mm |
| Volume (Metric) | 5 μL |
| Length (English) | 2.75 in. |
| Diameter (Metric) Inner | 0.343 mm |
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger) |
| Max. Temperature (Metric) | 50°C |
| Max. Pressure | 2000 psi |
| For Use With (Equipment) | PerkinElmer Autosystem and Clarus 500 GCs |
| Product Type | Microliter Syringe |
| Diameter (Metric) Outer | 6.6 mm |
| Connection Type | Cemented |
| Max. Temperature (English) | 122°F |
| Diameter (English) Outer | 0.26 in. |
| Model | 75 N |
| Needle Point Style | Blunt |
| Length (English) Needle | 2.75 in. |
| Autoclavable | Not Autoclavable |
| Min. Temperature (Metric) | 10°C |
MilliporeSigma™ Supelco™ SGE Syringes, Cone Tip
For use with Agilent/HP 7673, 7683 and 6850 ALS Autosamplers
| Needle Point Number | 1 |
|---|---|
| For Use With (Equipment) | Agilent 7673, 7683, 6850 ALS Autosampler |
| Product Type | SGE Syringe |
| Needle Point Style | Cone |
| Material | Stainless Steel (Tip) |
| Length (Metric) Needle | 42 mm |
Thermo Scientific™ GC Syringes for TriPlus™ RSH Autosampler
Easily accomplish accurate, precise, and reproducible injections with Thermo Scientific™ GC Syringes for Thermo Scientific™ TriPlus™ RSH Autosampler.
Hamilton™ Gastight™ Syringe, 10 μL, Sold by MilliporeSigma™ Supelco™
For use with Agilent GC Autosamplers 7693A, 7673, 7683, and 6850 ALS
| Needle Point Number | 1 |
|---|---|
| For Use With (Equipment) | Agilent 7673, 7683, 7693A and 6850 Autosamplers |
| Product Type | Gastight™ Syringe |
| Volume (Metric) | 10 μL |
| Needle Point Style | Cone |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),PTFE (Plunger),Stainless Steel (Tip) |
| Length (English) Needle | 1.71 in. |
| Length (Metric) Needle | 43 mm |
| Min. Temperature (Metric) | 10°C |
| Max. Pressure | 1000 psig (68.9 bar) |
| Product Line | Hamilton |
Valco™ Precision Sampling Syringe, Magnum Series, Sold by MilliporeSigma™ Supelco™
Ideal for collection, trace analysis, and sample concentration of environmental contaminants
| Description | Magnum Series |
|---|---|
| Product Type | Precision Sampling Syringe |
| Connection Type | Removable |
| Needle Point Style | Bevel |
| Quantity | 1 Ea. |
| Material | Borosilicate Glass (Barrel) |
| Length (English) Needle | 2 in. |
| For Use With (Application) | Collection, Trace Analysis and Sample Concentration of Environmental Contaminants |
| Diameter (English) Outer Needle | 0.035 in. |
| Diameter (English) Inner Needle | 0.023 in. |
| Product Line | Valco |
Valco™ Precision Sampling Syringe, Series A, Sold by MilliporeSigma™ Supelco™
Allows storage of sample within the syringe. Rotary valve in the needle hub for pre-pressurization of the sample prior to injection.
| Needle Point Number | 2 |
|---|---|
| Description | Series A |
| Product Type | Precision Sampling Syringe |
| Connection Type | Removable |
| Needle Point Style | Bevel |
| Quantity | 1 Ea. |
| Material | Stainless Steel (Tip) |
| Length (English) Needle | 2.25 in. |
| Max. Pressure | 250 psi |
| Diameter (English) Outer Needle | 0.029 in. |
| Diameter (English) Inner Needle | 0.012 in. |
| Product Line | Valco |