Test
Accessory for the Enviro-Genie 6-in-1 and Roto-Shake Genie 6-in-1, two stainless steel trays & 24 magnetic mounting bag strips.
Pre-treated, pre-weighed, and disposable for your convenienceThis product complies with the following methods: SM 2540, ASTM D5907, BS EN 15216:2007Save time — cools faster, requires fewer drying and weighing cyclesDisposable to eliminate cross-contaminationThese weighing vessels reduce preparation time, perfect for busy labs analyzing a lot of samples. Each vessel complies with the following methods: SM 2540, ASTM D5907, BS EN 15216:2007. Each vessel is treated to conform with ASTM D5907 Standard Test Methods for Filterable Matter (Total Dissolved Solids) and Nonfilterable Matter (Total Suspended Solids) in Water, then individually printed with the final weight. The material is lightweight, inert to water or wastewater components, and heat resistant. Vessels cool quickly decreasing wait times between heating and weighing.
Aluminum Skimmer Cone – Aluminum skimmer cone for PerkinElmer NexION 1000/2000/300/350 ICP-MS. For lowest nickel background and laser ablation applications. Not recommended for samples containing HF. Use 10x Magnifier Inspection Tool with Built-In LED Illumination (NC2042261) to inspect cone orifice condition. When not in use, keep cones stored in original packaging for protection. Use skimmer ConeGuard to protect cone threads during cleaning, 70-803-1026.For standard samples and routine operation, we recommend Nickel Skimmer Cones, 501907685. For corrosive samples, including HF, we recommend Platinum Skimmer Cones, see catalog number 501907688.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
MicroMist DC Nebulizer 0.1 mL/min, includes UniFit Connector with 0.25mm ID x 1.3mm OD x 700mm long tubing (1 pc.) and DC Gas Fitting Type 13/31 with ratchet connector (1 pc.). Compatible with Thermo PRO Duo, PRO Radial, 6000/7000 Duo & Radial Series ICP-OES.Optimum nebulizer gas flow rate is 0.7L/min and sample flow rate is 0.1mL/min. Recommended not to exceed optimum 0.1mL/min sample flow rate; however, lower gas and sample flow rates are OK. The backpressure should read ~40 psi at 0.7L/min gas flow rate. Can tolerate up to 15% TDS. MicroMist is the standard configuration for many ICP manufacturers due to its excellent sensitivity and precision at low flow rates.Replacement parts include P/Ns NFT-025 and 501907289.Recommend maintenance tools are Fluka RBS25 (P/N NC9000117) and Eluo Nebulizer Cleaning Tool (P/N NC9462559). When not in use, best to store in the provided hard plastic case.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
UniFit Connector with 0.25mm ID x 1.3mm OD x 700mm long tubing sample tube. Package of 10 replacement sample lines. Compatible with Glass Expansion U-Series and DC Series Nebulizers. Used to carry sample from peristaltic pump tubing or mixing T to nebulizer. This consumable part should be replaced at a frequency of about every 6 months to ensure optimum sample flow.For the same UniFit Connectors with the same ID but a longer sample tube length of 1500mm, NFTS-075. For UniFit Connector with 0.5mm ID, 1.3mm OD x 700mm long sample tube, NC1625341. For UniFit Connector with 0.18mm ID, 1.3mm OD x 700mm long sample tube, NC1973499.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
UniFit-08-4 Assembly (PKT 4). GazFit/UniFit drain fitting for 8mm OD HydraMist spray chamber drain and barbed end for soft walled tubing for peristaltic pump.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Aluminum Sampler Cone – For Thermo/Finnigan Element 1, 2 & Neptune ICP-MS. Use for lowest Ni background, and laser ablation applications. Not recommended for samples containing hydrofluoric acid (HF). Use a new Graphite Sampler Cone Gasket (501907717) each time the cone is re-installed, even if it’s the same cone. Use 10x Magnifier Inspection Tool with Built-In LED Illumination (NC2042261) to inspect cone orifice condition. When not in use, keep cones stored in original packaging for protection.For lowest boron background and semiconductor applications, we recommend a platinum cone, see catalog number 501907711.For high sensitivity applications and low matrix containing samples, we recommend Nickel Jet Sampler, see catalog number 501907709.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
PTFE Sheathed Carbon Fiber Probe 0.75mm ID with 1/4-28 Ratchet Fitting. Suitable for Cetac ASX-200/500/800 and PerkinElmer S20 Series. Swage Tool for Ratchet Connector (50-100-1811, sold separately), allows probe capillary to be cut to a custom length.Replacement of autosampler probe is recommended about every 6 months to a year. This will ensure you have unrestricted sample flow. If clogs within probes or nebulizers occur, consider using the Guardian In-Line Sample Filter (P/N NC0897716, 70-803-1108). The Guardian In-Line Sample Filter is spliced into the autosampler probe capillary & can be backflushed using the Eluo Nebulizer Cleaner for Glass Concentric Nebulizers (NC9462559, 70-ELUO), or the Eluo HF Nebulizer Cleaner for OpalMist or DuraMist (501907353, 70-ELUO-OPD), & Eluo Adaptor for In-Line Filter (NC0801128, 70-803-1160). The Guardian In-Line Sample Filter is reuseable & can last years.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Viton O-rings for base of HF Tracey spray chamber (PKT 10). The O-Ring removal tool (50-100-1636) facilitates the removal and installation of O-rings. This tool is especially handy while wearing PPE that can limit dexterity.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
EzyFit with 1.6mm (1/16”) OD X 0.25mm ID x 700mm long sample tube. Package of 10 replacement sample lines compatible with Glass Expansion F-Series Nebulizers. Used to carry sample from peristaltic pump tubing to nebulizer or to carry internal standard to Glass Expansion’s Trident IS Kit for HF P/N NC2046964, 60-808-1150. This consumable part should be replaced at a frequency of about every 6 months to ensure optimum sample flow.For EzyFit Connector with 0.50mm ID, 1.6mm (1/16”) OD x 700mm long sample tube, EZT-16-50. For EzyFit Connector with 0.75mm ID, 1.3mm OD x 1500mm long sample tube, EZTS-075. For EzyFit Connector with 0.25mm ID, 1.3mm OD x 700mm long sample tube, EZT-025.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
PTFE Sheathed Carbon Fiber Probe 0.5mm ID with UniFit Connector. Suitable for Cetac ASX-200/500/800 and PerkinElmer S20 Series Autosamplers. UniFit Connector attaches directly to Glass Expansion U-Series and DC Nebulizers.Replacement of autosampler probe is recommended about every 6 months to a year. This will ensure you have unrestricted sample flow. If clogs within probes or nebulizers occur, consider using the Guardian In-Line Sample Filter (P/N NC0897716, 70-803-1108). The Guardian In-Line Sample Filter is spliced into the autosampler probe capillary & can be backflushed using the Eluo Nebulizer Cleaner for Glass Concentric Nebulizers (NC9462559, 70-ELUO), or the Eluo HF Nebulizer Cleaner for OpalMist or DuraMist (501907353, 70-ELUO-OPD), & Eluo Adaptor for In-Line Filter (NC0801128, 70-803-1160). The Guardian In-Line Sample Filter is reuseable & can last years.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Standard Sample Tubing 1/16OD x 0.75mm ID x 10m long. Ten meters (32.8 ft) of chemically resistant PFA sample tubing. Outside diameter of 1/16” and internal diameter of 0.75 mm.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
UniFit Connector with 1/16 OD X 0.50mm ID x 700mm long sample tube. Package of 10 replacement sample lines. Compatible with Glass Expansion U-Series and DC Series Nebulizers. Used to carry sample from peristaltic pump tubing or mixing T to nebulizer. This consumable part should be replaced at a frequency of about every 6 months to ensure optimum sample flow.For UniFit Connector with 0.5mm ID, 1.3mm OD x 700mm long sample tube, NC1625341. For UniFit Connector with 0.18mm ID, 1.3mm OD x 700mm long sample tube, NC1973499.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
SeaSpray DC Nebulizer 0.4 mL/min, includes UniFit Connector with 0.5mm ID x 1.3mm OD x 700mm long tubing (1 piece) and DC Gas Fitting Type 31 with ratchet connector (1 pc.). Compatible with Thermo PRO, 6000/7000 Series ICP-OES.Optimum nebulizer gas flow rate is 0.7 L/min and sample flow rate is 0.4 mL/min. Recommended not to exceed optimum 0.4 mL/min sample flow rate; however, lower gas and sample flow rates are OK. The backpressure should read approximately 40 psi at 0.7 L/min gas flow rate. Can tolerate up to 20% TDS. We recommend the use of the Elegra Argon Humidifier to achieve best performance with high TDS.Replacement parts include P/Ns NC1625341 and 501907289.Recommend nebulizer maintenance tools are Fluka RBS25 (P/N NC9000117) and Eluo Nebulizer Cleaning Tool (P/N NC9462559). When nebulizer is not in use, best to store in the provided hard plastic case.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Ratchet Connector. Glass Expansion’s ¼-28 Ratchet Connector Fitting for making capillary connections to ICP-OES and ICP-MS sample introduction components. Can be used with 1.6mm OD (1/16”) ferrules P/N 70-803-0749 or with 1.3mm OD ferrules P/N 70-803-0748 to terminate capillary tubing where ratchet fitting is required. Swage Tool for Ratchet Connector, P/N 50-100-1811, secures ferrule on capillary and allows desired capillary tube length to be terminated with appropriate ferrule and ratchet fitting.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001