Protein Mass Spectrometry Sample Prep
- (1)
- (1)
- (1)
- (6)
- (1)
- (1)
- (2)
- (1)
- (1)
- (4)
- (1)
- (1)
- (1)
- (1)
- (2)
- (2)
- (1)
- (2)
- (2)
- (1)
- (4)
- (1)
- (2)
- (2)
- (2)
- (4)
- (3)
- (1)
- (1)
- (2)
- (2)
- (2)
- (2)
- (2)
- (2)
- (1)
- (2)
- (8)
- (1)
- (2)
- (3)
- (2)
- (5)
- (6)
- (1)
- (1)
- (4)
- (3)
- (1)
- (14)
- (2)
- (1)
- (32)
- (10)
- (30)
- (34)
- (10)
- (7)
- (2)
- (8)
- (14)
- (1)
- (59)
- (2)
- (6)
- (1)
- (2)
- (5)
- (73)
- (6)
- (20)
- (4)
- (4)
- (26)
Filtered Search Results
Waters Corp Plate manifold reservoir tray 25/pk
Plate manifold reservoir tray 25/pk
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp GlycoWorks N-Glycan Kit, RapiFluor-MS, Automation, Eco Basic
The GlycoWorks RapiFluor-MS N-Glycan Kit – Automation provides materials for fast enzymatic release and rapid labeling of N-glycans, designed for automated, high-throughput glycoprotein sample preparation and N-glycan analysis.
- Automated processing for 48 or 96 samples.
- Rapid enzymatic release and dual-detection labeling with RapiFluor-MS.
- Efficient Solid-Phase Extraction (SPE) cleanup via HILIC μElution™ Plate.
- Expedited workflow: full automation of 96 samples in less than 3 hours.
- Includes RapiFluor-MS reagent, RapiGest SF surfactant, and Rapid PNGase F enzyme.
- Compatible with direct LC-MS analysis; optimized for 15 to 40 μg glycoproteins.
- Validated for monoclonal antibodies and various N-linked glycoproteins.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp GlycoWorks RapiFluor-MS N-Glyc
GlycoWorks RapiFluor-MS N-Glyc
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp GlycoWorks RapiFluor-MS N-Glycan Script Starter Kit, Automated, High-Throughput, 96 Analyses, LC-MS
This kit is designed for automated platforms, enabling high-throughput glycoprotein sample preparation for N-glycan analysis with minimal user intervention. Validated with monoclonal antibodies, it’s effective for a wide range of N-linked glycoproteins. Reagents are scaled to residual volumes, providing versatility for automated instrumentation.
- Automated platform compatibility.
- High-throughput N-glycan analysis.
- Minimal user intervention.
- Validated for monoclonal antibodies and N-linked glycoproteins.
- Reagents scaled for automated instrumentation.
- Includes scripts for faster automation results.
- 96 analyses (2 × 48 format).
- HILIC separation mode.
- Supports MS, HRMS, MS/MS, and UV detection.
- LC-MS system type.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp Application Kit, Rapi-Fluor-MS, N-Glycan, Eco Starter Kit, 24 Samples
This kit offers a streamlined, fast, and highly sensitive method for analyzing released N-glycans in three easy steps, reducing sample preparation to as little as 30 minutes. It uses RapiFluor-MS for increased fluorescence quantification and superior mass spectral response. The Eco Kit utilizes a greener DMSO alternative as a reagent solvent and processes 24 samples.
- Streamlined N-glycan analysis.
- Three-step preparation in under 30 minutes.
- Enhanced fluorescence and mass spectral response with RapiFluor-MS.
- Eco-friendly with safer DMSO solvent.
- Processes 24 samples.
- Optimized deglycosylation and rapid labeling.
- Efficient SPE clean-up.
- Minimal sample handling.
- Includes mass check standard.
- Minimum 1 year shelf life.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corporation GlycoWorks RapiFluor-MS N-Glycan Starter Kit, 96 Sample, HILIC, MS/MS, UV, HRMS Detection
This starter kit offers a streamlined, fast, and highly sensitive method for analyzing released N-glycans. It simplifies sample preparation to three easy steps, achievable in as little as 30 minutes. The RapiFluor-MS reagent provides increased fluorescence quantification and mass spectral response, enabling valuable information from characterization to routine monitoring for 96 samples.
- Streamlined, fast, and highly sensitive N-glycan analysis.
- Three easy sample preparation steps in as little as 30 minutes.
- RapiFluor-MS reagent for increased fluorescence quantification and mass spectral response.
- Processes 96 samples in a 4x24 format.
- Includes modules for deglycosylation, labeling, clean-up, and sample collection.
- Optimized for glycoprotein quantity up to 40 μg.
- Rapid workflow: deglycosylation <15 min, labeling 5 min, clean-up 10 min.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp GlycoWorks RapiFluor-MS N-Glycan Eco Script Starter Kit, ACQUITY Premier Glycan BEH Column, Automation
This kit enables automated, high-throughput glycoprotein sample preparation for N-glycan analysis with minimal user intervention. Validated with monoclonal antibodies, it supports various N-linked glycoproteins. Reagents are scaled for automated platforms, offering versatility. Eco kits replace DMF with greener DMSO solvent.
- Automated, high-throughput glycoprotein sample preparation.
- Fast enzymatic release and rapid N-glycan labeling.
- Novel rapid label for sensitive fluorescence and mass detection.
- Efficient solid-phase extraction cleanup.
- Processes 96 samples in under 3 hours when automated.
- Eco-friendly formulation with DMSO solvent.
- Includes deglycosylation, labeling, cleanup, and collection modules.
- Supplied with glycan BEH Amide Column and mobile phase concentrate.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp N-Glycan Starter Kit, RapiFluor-MS, 96 Samples
This starter kit provides a streamlined and highly sensitive method for N-glycan analysis. It simplifies sample preparation into three easy steps, completed in as little as 30 minutes. The RapiFluor-MS technology offers increased fluorescence and superior mass spectral response, enabling comprehensive glycan characterization and routine monitoring.
- Streamlined, fast, and highly sensitive N-glycan analysis.
- Sample preparation in three easy steps, completed in as little as 30 minutes.
- RapiFluor-MS technology for increased fluorescence and superior mass spectral response.
- Processes 96 samples in a 4x24 format.
- Includes deglycosylation, labeling, clean-up, and sample collection modules.
- Features a UPLC glycan BEH amide column and mobile-phase concentrate.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp N-Glycan Sample Preparation Kit, Eco-Friendly, Automation, 2 x 48 Format
This kit enables high-throughput glycoprotein sample preparation for N-glycan analysis, ideal for automated platforms with minimal user intervention. Validated with monoclonal antibodies and effective for various N-linked glycoproteins, this eco-friendly kit replaces DMF with DMSO and removes other DMF-containing solutions. It is provided in a 2 x 48 format.
- Rapid labeling for sensitive fluorescence detection and strong mass signal intensity.
- Streamlined protocol with fast deglycosylation, labeling, and cleanup steps.
- Designed for full automation on compatible platforms, processing 96 samples in under 3 hours.
- Optimized reagents ensure efficient deglycosylation and prevent precipitation.
- Efficient cleanup through solid-phase extraction removes reaction by-products.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp GlycoWorks RFMS N-Glycan Starter Kit, 96 analyses, Sample Preparation Workflow
Re-imagine a streamlined, fast, and highly sensitive way to analyze released N-glycans. The GlycoWorks RapiFluor-MS N-Glycan Kit simplifies sample preparation into just 3 easy steps in as little as 30 minutes, eliminating complicated and time-consuming processes. The unique chemical attributes of RapiFluor-MS (RFMS) provide increased fluorescence quantification and superior mass spectral response. This allows for the use of a single label to gather valuable information, from characterization to routine monitoring, making glycan analysis easier and more sensitive.
- GlycoWorks deglycosylation module
- GlycoWorks labeling module
- GlycoWorks clean-up module
- GlycoWorks sample collection module
- ACQUITY UPLC glycan BEH amide column, 130Å, 1.7μm, 2.1 x 150 mm
- 5050 mM ammonium formate solution—glycan analysis
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp ProteinWorks Auto-eXpress Low Trypsin Kit - Cold Storage Refill Kit
ProteinWorks Auto-eXpress Low Trypsin Kit - Cold Storage Refill Kit
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp N-Glycan Eco Starter Kit, Automation, RapiFluor-MS, 2 x 48 Format
The GlycoWorks RapiFluor-MS N-Glycan Eco Starter Kit – Automation is designed for automated platforms, enabling high-throughput glycoprotein sample preparation for N-glycan analysis. It is validated for monoclonal antibodies and other N-linked glycoproteins. This kit uses DMSO as a greener, safer alternative for the RapiFluor-MS Reagent Label, replacing DMF.
- Designed for automated glycoprotein sample preparation.
- Validated for monoclonal antibodies and N-linked glycoproteins.
- Reagents scaled for automated instrumentation.
- Replaces DMF with greener DMSO for RapiFluor-MS Reagent Label.
- Removes other DMF-containing solutions.
- Includes RFMS labeled standard, column, and mobile phase concentrate.
- Kit format: 2 x 48.
- Suggested use: Eco-friendly, released N-linked glycan analysis, automation.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp GlycoWorks RapiFluor-MS N-Glycan Script Parameters Starter Kit, Automation, 96 Analyses
The GlycoWorks RapiFluor-MS N-Glycan Script Parameters Starter Kit – Automation enables high-throughput glycoprotein sample preparation for N-glycan analysis on automated platforms. Validated for monoclonal antibodies and various other N-linked glycoproteins, it streamlines workflows for glycan detection with unmatched fluorescent and mass spectrometric performance.
- Designed for automated, high-throughput sample prep
- Validated with mAbs and compatible with N-linked glycoproteins
- Reagents scaled for automated instruments, offering versatility
- Includes script guidelines and liquid class table
- Label provides high mass spectral signal for low abundance glycans
- Contains deglycosylation, labeling, clean-up, and sample collection modules
- Supports 96 analyses
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp ProteinWorks eXpress Direct Digest Kit - Cold Storage Refill Kit
ProteinWorks eXpress Direct Digest Kit - Cold Storage Refill Kit
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp GlycoWorks Sample Collection Module, 1 mL, 600 μL, Automation
This GlycoWorks Sample Collection Module provides the necessary components for efficient sample cleanup, minimizing sample transfer during glycan analysis workflows. It includes specialized tubes, tube inserts, and cap strips designed for deglycosylation, labeling reactions, and solid phase extraction (SPE) eluate collection. The module is suitable for automated processes and ensures proper heating when used with compatible heat blocks.
- Includes 15 1 mL tubes for deglycosylation and labeling reactions.
- Includes 15 600 μL tube inserts for SPE eluate collection.
- Contains 15 cap strips with slits for direct injection.
- Includes one 1 mL round collection tray.
- Includes one waste tray.
- Tubes are customized to ensure proper heating with compatible heat blocks.
- Can be stored at room temperature.
- Unopened products have a minimum shelf life of 1 year.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More